AAD130-3404A Tamura, AAD130-3404A Datasheet

Linear & Switching Power Supplies 130W 5V/+12V/-12V

AAD130-3404A

Manufacturer Part Number
AAD130-3404A
Description
Linear & Switching Power Supplies 130W 5V/+12V/-12V
Manufacturer
Tamura
Datasheet

Specifications of AAD130-3404A

Product
Switching
Commercial/medical
Commercial
Output Power Rating
70 W
Input Voltage
90 VAC to 264 VAC
Number Of Outputs
3
Output Voltage (channel 1)
5 V
Output Current (channel 1)
14 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
5 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
1.5 A
Mounting Style
Chassis
Dimensions
127 mm L x 31.75 mm W x 79.76 mm H
Open Frame/enclosed
Open Frame
Output Type
AC/DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
AAD130
130 Watts output power
Power Factor Correction
Parallel/Redundant Operation
Up to 88% Efficiency
Electrical Specifications
Available Voltage
Input Voltage:
Input Current:
Inrush Current:
Power Factor:
Harmonic Distortion:
EMI Filtering:
Input Protection:
Surge Withstand:
Output Power:
Line Regulation:
Load Regulation:
PARD:
Hold-up Time:
Turn-on Delay:
Output Polarity:
Minimum Load:
Transient Response:
Output Rise Time:
Example: Part Number AAD130-3244-AM = 130W Power Factor Corrected, (V1) +5V @ 14A, (V2) +3.3V @ 16A, (V3) +12V @ 1.5A and
(V4) -12V @ 1.5A with Current Sharing and Metric Mounting.
CLICK HERE TO SEE THE AAD130 CODE TABLE AND AVAILABLE OPTIONS.
Model
* Consult factory for other voltages and OEM quantities.
** Standard Polarity for V4 is negative (-). V4 is available with positive polarity as a Tailored or Custom model.
Note: Standard models are 3244, 3255, 3264, 3404 and 3464
PART # STRUCTURE:
Codes
Voltage
-1
-2
-3
-4
-5
-6
MODEL
AAD130
Voltages
(Volts)
+1.8
+3.3
V1
-
-
+5
90-264 VAC, 47-63 Hz
<2A RMS @ 115 VAC @ full load
<35A, pk @ 132 VAC @ cold start
>0.98 @ full load @ 115/230VAC input
Meets EN61000-3-2
Meets CISPR 11 and 22 and FCC Part 15
Internal AC line fuse; 250 VAC, 4.0A
Meets EN61000-4
130W with 15CFM air; 80W Convection
± 0.3%
± 1% for V1 and V2
Greater of 1% or 50mV
>20 ms @ full load
<2 seconds
See Voltage Chart
>0.5A for V1 and V2
Greater of 150mV or 3% for 25%
<100 ms (10% to 90%)
<1A RMS @ 230 VAC @ full load
<75A, pk @ 264 VAC @ cold start
Class B (conducted)
cooled (consult factory for current ratings)
± 5% for V3 and V4
20MHz bandwidth
>0.1A for V3 and V4
load change @ 1A/μs (V1 and V2)
Outputs*
VOLTAGE CODE
V1 V2 V3 V4
-
Currents
(Amps)
14
14
14
V1
X
X
-
X
-
Voltages
Miniature Switch Mode Power Supply
(Volts)
+1.8
+3.3
+12
V2
+5
X
OPTION CODES
-
Currents
(Amps)
Remote Sense:
AC Power Fail:
Overshoot/Undershoot:
Current Share (option):
Overvoltage Protect:
Short Circuit Protection:
Reverse Voltage:
Case Power Protection:
Efficiency:
MTBF:
16
16
14
V2
5
ABC....
(See sheet 2)
H.A.L.T.
Voltages
(Volts)
+1.8
+3.3
+15
+12
+24
V3
+5
TESTED
Standard on V1 and V2
TTL
<5% overshoot with remote sense at output
Load currents of V1 and V2 for similar units
Factory set, 125% ±5% on V1 and V2
All outputs are auto recovery
Reverse current up to rated outputs
Standard operation interrupt (hiccup mode)
Up to 88%
MIL-STD-HDBK 217E
Up to 400mV of cable drop
output drops 5% (without signal jitter).
<10mA sink current for Power Fail "0".
<1mA source current for Power Fail "1".
terminals
can be shared @ <±5% of total load
cycle AC to reset
>200,000 hours @ 25°C
Highly Accelerated Life Testing
Currents
(Amps)
LOW
1.5
1.5
1.5
1.5
1.5
1.5
V3
logic “0” at least 5 ms before DC
Highly
Accelerated
Life
Testing
Voltages
(Volts)
V4
-1.8
-3.3
-24
-12
-15
-5
**
Currents
(Amps)
V4
1.5
1.5
1.5
1.5
1.5
1.5

Related parts for AAD130-3404A

AAD130-3404A Summary of contents

Page 1

... VOLTAGE CODE - AAD130 - Example: Part Number AAD130-3244-AM = 130W Power Factor Corrected, (V1) +5V @ 14A, (V2) +3.3V @ 16A, (V3) +12V @ 1.5A and (V4) -12V @ 1.5A with Current Sharing and Metric Mounting. CLICK HERE TO SEE THE AAD130 CODE TABLE AND AVAILABLE OPTIONS. Miniature Switch Mode Power Supply H.A.L.T. ...

Page 2

... Model AAD130 Options (code) #6-32 PEM Nut (Standard) Current Sharing (A) PF Invert (B) Thru-Hole Mounting (C) Metric Mounting (M) PF Open Collector (O) Input and Options with Gold Pins (G) Molex Output Connector with Gold Pins (J) Molex Connectors with Standard Pins (K) Compliance EN61000-4-5 Level 3 EN61000-4-2 Level 2 ...