LPP-100-15 Mean Well, LPP-100-15 Datasheet

Linear & Switching Power Supplies 100.5W 15V 6.7A With PFC Function

LPP-100-15

Manufacturer Part Number
LPP-100-15
Description
Linear & Switching Power Supplies 100.5W 15V 6.7A With PFC Function
Manufacturer
Mean Well
Datasheet

Specifications of LPP-100-15

Product
Switching
Commercial/medical
Commercial
Output Power Rating
101 W
Input Voltage
85 VAC to 264 VAC, 120 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
15 V
Output Current (channel 1)
6.7 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY(Typ.)
EMI CONDUCTION & RADIATION
100W Single Output with PFC Function
Note.5
Note.3
Note.2
LPP-100-3.3 LPP-100-5
3.3V
20A
0 ~ 20A
66W
100mVp-p
3.14 ~ 3.63V 4.75 ~ 5.5V
600ms, 30ms/230VAC
28ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
PF>0.95/230VAC
105 ~ 150%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3.8 ~ 4.45V
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
224.3Khrs min.
222*62*32mm (L*W*H)
0.51Kg; 24pcs/13.9Kg/1.39CUFT
69%
1.7A/115VAC
COLD START 30A/230VAC
<2mA / 240VAC
2.0%
0.5%
1.0%
0.05%/
(0 ~ 50
rated output power
(Refer to output load derating curve)
5V
20A
0 ~ 20A
100W
100mVp-p
5.75 ~ 6.75V 8.6 ~ 10.1V
75%
2.0%
0.5%
1.0%
I/P-FG:1.5KVAC
120 ~ 370VDC
MIL-HDBK-217F (25 )
0.75A/230VAC
28ms/115VAC at full load
PF>0.98/115VAC at full load
1200ms, 30ms/115VAC at full load
LPP-100-7.5 LPP-100-12 LPP-100-13.5 LPP-100-15 LPP-100-24 LPP-100-27 LPP-100-48
7.5V
13.5A
0 ~ 13.3A
101.25W
100mVp-p
7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
76%
2.0%
0.5%
1.0%
O/P-FG:0.5KVAC
12V
8.5A
0 ~ 8.5A
102W
100mVp-p
13.8 ~ 16.2V 15.5 ~ 18.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31 ~ 36.45V 55.2 ~ 64.8V
79%
2.0%
0.5%
0.5%
13.5V
7.5A
0 ~ 7.5A
101.25W
100mVp-p
79%
2.0%
0.5%
0.5%
15V
6.7A
0 ~ 6.7A
100.5W
100mVp-p
80%
2.0%
0.5%
0.5%
L P P - 1 0 0
24V
4.2A
0 ~ 4.2A
100.8W
150mVp-p
83%
1.0%
0.5%
0.5%
File Name:LPP-100-SPEC 2010-10-18
27V
3.8A
0 ~ 3.8A
102.6W
150mVp-p
83%
1.0%
0.5%
0.5%
s e r i e s
48V
2.1A
0 ~ 2.1A
100.8W
250mVp-p
83%
1.0%
0.5%
0.5%

Related parts for LPP-100-15

LPP-100-15 Summary of contents

Page 1

... HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 224.3Khrs min. OTHERS DIMENSION 222*62*32mm (L*W*H) 0.51Kg; 24pcs/13.9Kg/1.39CUFT PACKING NOTE LPP-100-7.5 LPP-100-12 LPP-100-13.5 LPP-100-15 LPP-100-24 LPP-100-27 LPP-100-48 5V 7.5V 12V 20A 13.5A 8. 20A 0 ~ 13. 8.5A 100W 101.25W ...

Page 2

... CN2 ADJ. Assignment Mating Housing Terminal -V JST VHR JST SVH-21T-P1.1 or equivalent or equivalent +V PFC fosc : 67KHz PWM fosc : 134KHz & FILTER COSTANT CURRENT LIMITING & DETECTION CIRCUIT O.V.P. 100 115 135 155 230 INPUT VOLTAGE (V) 60Hz File Name:LPP-100-SPEC 2010-10- Unit: 264 ...