HLG-240-36A Mean Well, HLG-240-36A Datasheet

Linear & Switching Power Supplies 241.2W 36V 6.7A 90-264VAC IP65 rated

HLG-240-36A

Manufacturer Part Number
HLG-240-36A
Description
Linear & Switching Power Supplies 241.2W 36V 6.7A 90-264VAC IP65 rated
Manufacturer
Mean Well
Datasheet

Specifications of HLG-240-36A

Product
Switching
Commercial/medical
Commercial
Output Power Rating
240 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 373 VDC
Number Of Outputs
1
Output Voltage (channel 1)
36 V
Output Current (channel 1)
6.7 A
Mounting Style
Panel
Dimensions
244.2 mm L x 68 mm W x 38.8 mm H
Open Frame/enclosed
Enclosed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
OTHERS
NOTE
DC VOLTAGE
CONSTANT CURRENT REGION
RATED CURRENT
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
240W Single Output Switching Power Supply
Note.6
Note.5
Note.3
Note.4
Note.2
Note.8
Note.7
Note.4
HLG-240-12
12V
6 ~12V
16A
192W
150mVp-p
11.2 ~ 12.8V
Can be adjusted by internal potential meter or through output cable
8 ~ 16A
2500ms, 80ms at full load
15ms at full load
90 ~ 264VAC
47 ~ 63Hz
PF 0.95/230VAC
1.3Kg; 12pcs/16.6Kg/0.74CUFT(HLG-240-Blank/A/B)
COLD START 75A/230VAC
<0.75mA / 240VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
Protection type : Shut down and latch off o/p voltage, re-power on to recover
105
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-40 ~ +60 @ full load ; +70 @ 60% load (Refer to derating curve)
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL1012, TUV EN61347-1, EN61347-2-13 independent (except for HLG-240H C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67 approved
I/P-O/P:3.75KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B
Compliance to EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A
207.9Khrs min.
244.2*68*38.8mm (L*W*H)(HLG-240-Blank/A/B)
90%
4A / 115VAC
15.5 ~ 18V
2.5%
0.5%
2.0%
0.03%/
5
(0 ~ 50 )
(TSW1)
HLG-240-15
15V
7.5 ~ 15V
15A
225W
150mVp-p
7.5 ~ 15A
90%
16.5 ~ 19.5V 22 ~ 26V
14 ~ 16V
2.0%
0.5%
1.5%
2A / 230VAC
127 ~ 373VDC
MIL-HDBK-217F (25 )
230VAC /115VAC
I/P-FG:1.88KVAC
PF 0.98/115VAC at full load and rated output voltage
230VAC /115VAC
HLG-240-20
20V
10 ~ 20V
12A
240W
150mVp-p
18.6 ~ 21.4V
6 ~ 12A
92%
95
1.0%
0.5%
1.0%
5
(TSW1)
HLG-240-24
24V
12 ~ 24V
10A
240W
150mVp-p
22.4 ~ 25.6V
5 ~ 10A
O/P-FG:0.5KVAC
26 ~ 33V
93%
1.0%
0.5%
0.5%
251*68*38.8mm (L*W*H)(HLG-240-C)
HLG-240-30
30V
15 ~ 30V
8A
240W
200mVp-p
28 ~ 32V
4 ~ 8A
93%
32.5 ~ 36.5V 40 ~ 48V
1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
1.0%
0.5%
0.5%
IP65 IP67
HLG-240-36
36V
18 ~ 36V
6.7A
241.2W
250mVp-p
33.5 ~ 38.5V
3.3 ~ 6.7A
93.5%
1.0%
0.5%
0.5%
H L G - 2 4 0
PF 0.9 at 65 ~ 100% load
HLG-240-42
42V
21 ~ 42V
5.72A
240.2W
250mVp-p
39 ~ 45V
2.86 ~ 5.72A
94%
46 ~ 50V
1.0%
0.5%
0.5%
HLG-240-48
48V
24 ~ 48V
5A
240W
250mVp-p
44.8 ~ 51.2V
2.5 ~ 5A
94%
53 ~ 62V
1.0%
0.5%
0.5%
s e r i e s
HLG-240-54
54V
27 ~ 54V
4.45A
240.3W
350mVp-p
50 ~ 57V
2.23 ~ 4.45A
94%
59 ~ 65V
1.0%
0.5%
0.5%

Related parts for HLG-240-36A

HLG-240-36A Summary of contents

Page 1

... ENVIRONMENT TEMP. COEFFICIENT 0.03%/ VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along axes SAFETY STANDARDS UL1012, TUV EN61347-1, EN61347-2-13 independent (except for HLG-240H C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67 approved Note.7 WITHSTAND VOLTAGE I/P-O/P:3.75KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH ...

Page 2

... IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter. (Can access by removing the rubber stopper on the case.) 244.2 220.2 12 9.6 244.2 220 Case No.954C 300 20 SJTW 14AWG 2C 4.2 4PL 300 ADJ. ADJ. SJTW 14AWG 2C 4.2 4PL File Name:HLG-240-SPEC 2011-01- Unit:mm +V(Red) -V(Black) +V(Red) -V(Black) ...

Page 3

... Open Open 820 1.8K 680 620 820 120 500 82 68 150 Short Short Short Short Short AC Input Terminal Pin No. Assignment 1 Pin No. O ADJ 4.2 4PL DC Output Terminal Pin No. Assignment Pin No File Name:HLG-240-SPEC 2011-01- +V(Red) -V(Black) ADJ1(Blue) ADJ2(White) Assignment FG AC/L AC/N Assignment -V +V ...

Page 4

... Power Factor Characteristic Power factor will be higher than 0.9 when output loading is 65% or higher. Constant Current Mode LOAD EFFICIENCY vs LOAD (48V Model) HLG-240 series possess superior working efficiency that up to 94% can be reached in field applications 10% 20% 30% 40% 50% LOAD POWER SWITCHING O.L.P. PWM & PFC ...

Page 5

... LED driver circuit should use 2.2uF ~ 22uF(typ.) of rating depends on the operating frequency of the LED driver. The higher the operating frequency is used, the smaller value of Cin should be chosen, and vice versa. AC I/P HLG-240 source (B) Constant Current area (C) Hiccup Io (%) O/P O/P R Cin Cout L IC Circuit File Name:HLG-240-SPEC 2011-01- ...

Page 6

... A. Add a common mode ferrite choke on output wires to reduce the common emission between 10M ~ 300MHz per lighting EMI regulation. B. Chassis of LED lamp and chassis of HLG-240 or the FG wire should be connected to the safety ground to reduce the EMI noise, including the conduction and radiation emission. ...

Related keywords