S-150-12 Mean Well, S-150-12 Datasheet

Linear & Switching Power Supplies 150W 12V 12.5A

S-150-12

Manufacturer Part Number
S-150-12
Description
Linear & Switching Power Supplies 150W 12V 12.5A
Manufacturer
Mean Well
Datasheet

Specifications of S-150-12

Product
Switching
Output Power Rating
150 W
Input Voltage
88 VAC to 132 VAC, 176 VAC to 264 VAC, 248 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
12.5 A
Mounting Style
Rack
Dimensions
199 mm L x 110 mm W x 50 mm H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-150-12
Manufacturer:
MEANWELL
Quantity:
2 000
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
EMI CONDUCTION & RADIATION
150W Single Output Switching Power Supply
Note.5
Note.3
Note.2
S-150-5
5V
30A
0 ~ 30A
150W
150mVp-p
4.5 ~ 5.5V
100ms, 50ms at full load
28ms at full load
88 ~ 132VAC/176 ~ 264VAC selected by switch
47 ~ 63Hz
3.2A/115VAC
105 ~ 150% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
286.7K hrs min.
199*110*50mm (L*W*H)
0.8Kg; 16pcs/13.8Kg/0.95CUFT
78%
COLD START 35A
<3.5mA / 240VAC
5.75 ~ 6.75V
2.0%
0.5%
0.5%
0.03%/
(0 ~ 50
(Refer to output load derating curve)
S-150-7.5
7.5V
20A
0 ~ 20A
150W
150mVp-p
6 ~ 8.3V
8.63 ~ 10.13V
80%
1.0%
0.5%
0.5%
I/P-FG:1.5KVAC
1.6A/230VAC
MIL-HDBK-217F (25 )
S-150-9
9V
16.7A
0 ~ 16.7A
150.3W
180mVp-p
8 ~ 10.4V
10.35 ~ 12.2V
80%
1.0%
0.3%
0.3%
O/P-FG:0.5KVAC
S-150-12
12V
12.5A
0 ~ 12.5A
150W
180mVp-p
10.6 ~ 13.2V 12 ~ 15V
13.8 ~ 16.2V
82%
1.0%
0.3%
0.3%
248 ~ 370VDC
S-150-13.5
13.5V
11.2A
0 ~ 11.2A
151.2W
180mVp-p
15.53 ~ 18.2V
83%
1.0%
0.3%
0.3%
S-150-15
15V
10A
0 ~ 10A
150W
180mVp-p
13.5 ~ 16.5V 21 ~ 28V
17.25 ~ 20.3V
84%
1.0%
0.3%
0.3%
S-150-24
24V
6.5A
0 ~ 6.5A
156W
240mVp-p
30 ~ 34.8V
85%
1.0%
0.2%
0.2%
S - 1 5 0
File Name:S-150-SPEC 2010-10-18
S-150-27
27V
5.6A
0 ~ 5.6A
151.2W
240mVp-p
24 ~ 30V
31.1 ~ 36.45V
86%
1.0%
0.2%
0.2%
s e r i e s
S-150-48
48V
3.2A
0 ~ 3.2A
153.6W
240mVp-p
43 ~ 53V
55.2 ~ 64.8V
87%
1.0%
0.2%
0.2%

Related parts for S-150-12

S-150-12 Summary of contents

Page 1

... Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 286.7K hrs min. OTHERS DIMENSION 199*110*50mm (L*W*H) 0.8Kg; 16pcs/13.8Kg/0.95CUFT PACKING NOTE S-150-7.5 S-150-9 S-150-12 7.5V 9V 12V 20A 16.7A 12. 20A 0 ~ 16. 12.5A 150W 150.3W 150W 150mVp-p 180mVp-p 180mVp ...

Page 2

... PWM CONTROL 100 105 110 115 120 160 170 180 190 200 210 220 230 240 INPUT VOLTAGE (V) 60Hz INPUT VOLTAGE (V) 60Hz File Name:S-150-SPEC 2010-10- Unit:mm Assignment fosc : 25KHz +V -V Ta=25 350 300 250 200 150 100 50 125 130 250 260 ...

Related keywords