NFS40-7615J Emerson Network Power, NFS40-7615J Datasheet

Linear & Switching Power Supplies 40W 15V@3.3A

NFS40-7615J

Manufacturer Part Number
NFS40-7615J
Description
Linear & Switching Power Supplies 40W 15V@3.3A
Manufacturer
Emerson Network Power
Series
NFS40r
Datasheet

Specifications of NFS40-7615J

Product
Switching
Output Power Rating
40 W
Input Voltage
85 VAC to 264 VAC, 120 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
15 V
Output Current (channel 1)
2.6 A
Mounting Style
Chassis
Dimensions
5 in L x 3 in W x 1.2 in H
Open Frame/enclosed
Open Frame
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Safety
• VDE0805/EN60950/
• IEC950/IEC1010
• File No. 10401-3336-0044
• License No. 2559
• UL1950 File No. E136005
• CSA C22.2 No. 950
• File No. LR41062C
NFS40 Series
SIngle and
triple output
Total Power:
Input Voltage: 85 - 264 Vac
# of Outputs:
Special Features
• 5.0 x 3.0 x 1.2 inch package
• Industry standard package
• Overvoltage and
• 40 W with free air convection
• 50 W with 20 CFM forced air
• EN55022, EN55011
• UL, VDE and CSA
• Available RoHS compliant
• 2 year warranty
(1U applications)
short circuit protection
conducted noise level B
safety approvals
40 - 50W
120 - 370 Vdc
Single, triple
Electrical Specifications
Input
Output
Input voltage range:
Input frequency range:
Max. input surge current:
Safety ground leakage current:
Voltage adjustability:
Line regulation:
LL to HL, FL
Load regulation:
FL to NL
Transient response:
Temperature coefficient:
Overvoltage protection:
Output power limit:
Short circuit protection:
+5 V output on triples
Vout on singles
Main output
Auxiliary outputs
Main output
Auxiliary outputs
+5 V (1.5 - 3 A)
All outputs
+5 V output
Primary power limited
Single outputs
Multiple outputs
Universal input
132 Vac, cold start
264 Vac, cold star
110 Vac, 60 Hz
230 Vac, 50 Hz
Embedded Power for
Business-Critical Continuity
± 5.0%
± 5.0%
± 0.2%
± 1.0%
± 2.0%
± 5.0%
± 120 mV max. dev.
500 µs recovery
± 0.02%/°C
S3.15 A, 250 Vac In live and neutral
90 W input power limit
Continuous
Short term
85 - 264 Vac
120 - 370 Vdc
47-440 Hz
12 A max.
24 A max.
0.13 mA, max.
0.32 mA, max.
Rev.02.01.10_65
NFS40 Series
1 of 4

Related parts for NFS40-7615J

NFS40-7615J Summary of contents

Page 1

... Max. input surge current: 132 Vac, cold start 264 Vac, cold star Safety ground leakage current: 110 Vac 230 Vac Embedded Power for Business-Critical Continuity Rev.02.01.10_65 NFS40 Series ± 5.0% ± 5.0% ± 0.2% ± 1.0% ± 2.0% ± 5.0% ± 120 mV max. dev. ...

Page 2

... Perf. criteria 110 ms 70% typical 3000 Vac 1500 Vac 170,000 hours 0° +70 °C -40 °C to +85 ° CFM Derate linearly to 50% load 60W 5 to 80% RH 10,000 feet max. 40,000 feet max. 2.4 G rms peak Embedded Power for Business-Critical Continuity Rev.02.01.10_65 NFS40 Series ...

Page 3

... NFS40-7610J (5,6) ± 10.0%/-3.0% ± 5.0% ± 2.0% NFS40-76S3J ± 2.0% NFS40-7605J ± 2.0% NFS40-7612J ± 2.0% NFS40-7615J ± 2.0% NFS40-7624J Pin Connections -7607J -7610J AC Live AC Live AC Live AC Neutral AC Neutral AC Neutral +12 V + ...

Page 4

... P1. Use metal stand-offs attached to a common metal chassis. This connection also significantly attenuates common mode noise standard enclosure kit is available for mounting which contains all screws, connectors and necessary mounting hardware. Order part number NFS40CJ. 5.00 (127.00) ...