Clamp Multimeters & Accessories MULTIMETER CURRENT CLAMP

FLUKE-i30

Manufacturer Part NumberFLUKE-i30
DescriptionClamp Multimeters & Accessories MULTIMETER CURRENT CLAMP
ManufacturerFluke
FLUKE-i30 datasheet
 

Specifications of FLUKE-i30

Accuracy+/- 1 %FrequencyDC to 20 KHz (- 0.5 dB)
Maximum Ac Current20 AVoltage300 V
Ranging30 mA to 30 A DC, 30 mA to 20 A ACLead Free Status / RoHS StatusLead free / RoHS Compliant
Other names2584920  
1
Page 1
2
Page 2
Page 1/2

Download datasheet (142Kb)Embed
Next
Fluke i30
AC/DC Current Clamp
Electrical specifications
Specified current range: 30 mA to 30 A DC,
30 mA to 20 A AC rms
Usable current range: 5 mA to 30 A DC,
30 mA to 20 A AC rms
Crest factor: 1.4
Output sensitivity: 100 mV/A
Accuracy (at +25 °C): ± 1 % of reading ± 2 mA
Resolution: ± 1 mA
Load impedance: > 10 k Ohms and ≤ 100 pF
Conductor position sensitivity: ± 1 % relative to
center reading
Frequency range: DC to 20 kHz (- 0.5 dB)
Temperature coefficient: ± 0.01 % of reading/°C
Power supply: 9 V Alkaline, MN1604/PP3,
30 hours, low battery indicator
Working voltage (see Safety Standards section):
300 V ac rms or dc
Technical Data
The i30 current clamp is based
on Hall effect technology for use
in measurement of both dc and
ac current. The i30 may be used
in conjunction with multimeters,
recorders and other suitable
recording instruments for accurate
non-intrusive current measurement.
General specifications
Maximum conductor size: 19 mm (.748 in)
diameter
Output connection: 4 mm (.157 in) safety
connector
Output zero: Manual adjust via thumbwheel
Cable length: 1.5 m (4.91 ft)
Operating temperature range: 0 °C to +50 °C
(-32 °F to 122 °F)
Storage temperature range (with battery
removed): -20 °C to +85 °C (-4 °F to 185 °F)
Operating humidity: 15 % to 85 %
(non-condensing)
Weight: 250 g (.55 lb)

FLUKE-i30 Summary of contents

  • Page 1

    ... Fluke i30 AC/DC Current Clamp Electrical specifications Specified current range DC rms Usable current range DC rms Crest factor: 1.4 Output sensitivity: 100 mV/A Accuracy (at +25 °C): ± reading ± Resolution: ± Load impedance: > Ohms and ≤ 100 pF Conductor position sensitivity: ± relative to center reading Frequency range kHz (- 0 ...

  • Page 2