TOP258MG Power Integrations, TOP258MG Datasheet - Page 25

no-image

TOP258MG

Manufacturer Part Number
TOP258MG
Description
IC OFFLINE SWIT PROG OVP 10SDIP
Manufacturer
Power Integrations
Series
TOPSwitch®-HXr
Type
Off Line Switcherr
Datasheet

Specifications of TOP258MG

Output Isolation
Isolated
Frequency Range
59.4 ~ 72.6kHz
Voltage - Output
700V
Power (watts)
48W
Operating Temperature
-40°C ~ 150°C
Package / Case
10-SDIP (0.300", 7.62mm), 9 Leads
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
596-1336-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TOP258MG
Manufacturer:
POWER
Quantity:
15 000
Part Number:
TOP258MG
Manufacturer:
POWER
Quantity:
20 000
Key Application Considerations
TOPSwitch-HX vs. TOPSwitch-GX
Table 4 compares the features and performance differences
between TOPSwitch-HX and TOPSwitch-GX. Many of the new
TOPSwitch-HX vs. TOPSwitch-GX
Table 4.
www.powerint.com
Function
EcoSmart
Output Overvoltage
Protection (OVP)
Line Feed-Forward with Duty
Cycle Reduction
Switching Frequency DIP-8
Package
Lowest MOSFET On
Resistance in DIP-8 Package
I
Auto-restart Duty Cycle
Frequency Jitter
Thermal Shutdown
External Current Limit
Line UV Detection Threshold
Soft-Start
2
f Trimming
Comparison Between TOPSwitch-GX and TOPSwitch-HX.
TOPSwitch-GX
Linear frequency reduction to
30 kHz (@ 132 kHz) for
duty cycles < 10%
Not available
Linear reduction
132 kHz
3.0 Ω (TOP246P)
Not available
5.6%
±4 kHz @ 132 kHz
±2 kHz @ 66 kHz
130 °C to 150 °C
30%-100% of I
50 μA (2 MΩ sense
impedance)
10 ms duty cycle and current
limit ramp
LIMIT
TOPSwitch-HX
Multi-mode operation with
linear frequency reduction to
30 kHz (@ 132 kHz) and
multi-cycle modulation
(virtually no audible noise)
User programmable primary
or secondary hysteretic or
latching OVP
Dual slope reduction with
lower, more accurate onset
point
66 kHz
1.8 Ω (TOP258P)
-10% / +20%
2%
±5 kHz @ 132 kHz
±2.5 kHz @ 66 kHz
135 °C to 150 °C
30%-100% of I
trim at 0.7 × I
25 μA (4 MΩ sense
impedance)
17 ms sweep through multi-
mode characteristic
features eliminate the need for additional discrete components.
Other features increase the robustness of design, allowing cost
savings in the transformer and other power components.
LIMIT
LIMIT
, additional
TOPSwitch-HX Advantages
Improved effi ciency over load (e.g. at 25% load
point)
Improved standby effi ciency
Improved no-load consumption
Protects power supply output during open loop fault
Maximum design fl exibility
Improved line ripple rejection
Smaller DC bus capacitor
Increased output power for given MOSFET size due
to higher effi ciency
Increased output power in designs without external
heatsink
Increased output power for given core size
Reduced over-load power
Reduced delivered average output power during
open loop faults
Reduced EMI fi lter cost
Increased design margin
Reduced tolerances when current limit is set
externally
Reduced dissipation for lower no-load consumption
Reduced peak current and voltage component
stress at startup
Smooth output voltage rise
TOP252-262
Rev. F 01/09
25