R24P215S/X2/R6.4 Recom Power Inc, R24P215S/X2/R6.4 Datasheet

no-image

R24P215S/X2/R6.4

Manufacturer Part Number
R24P215S/X2/R6.4
Description
CONV DC/DC 2W 24VIN 15VOUT
Manufacturer
Recom Power Inc
Series
ECONOLINE RxxP2xx (R)r
Type
Isolatedr
Datasheet

Specifications of R24P215S/X2/R6.4

Operating Temperature
-40°C ~ 85°C
Power (watts) - Rated
2W
Efficiency
80 ~ 88%
Approvals
CSA, EN, UL
Output
15V
Number Of Outputs
1
Power (watts)
2W
Mounting Type
Through Hole
Voltage - Input
24V
Package / Case
7-SIP Module (4 Leads)
1st Output
15 VDC @ 132mA
Size / Dimension
0.77" L x 0.39" W x 0.49" H (19.5mm x 9.8mm x 12.5mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2nd Output
-
3rd Output
-
4th Output
-
E-60
Features
Unregulated
Converters
Selection Guide
Specifications (
Part
Number Isolation
SIP 7
RxxP23.3S
RxxP205S
RxxP209S
RxxP212S
RxxP215S
RxxP23.3D
RxxP205D
RxxP209D
RxxP212D
RxxP215D
xx = Input Voltage. Other input and output voltage combinations available on request.
No suffux is functional isolation e.g,
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
* add Suffix “/X2” for single output with alternative pinout, e.g.
* add Suffix “/R6.4” or “/R8” for Reinforced Isolation, e.g.
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Output Ripple and Noise (20MHz BW)
Operating Frequency
Efficiency at Full Load
Minimum Load = 0%
Isolation Voltage
/R6.4
/R8
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
P-Suffix
Operating Temperature Range (free air convection)
Storage Temperature Range
Relative Humidity
Standard Reinforced
(kVDC)
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
measured at T A = 25°C, nominal input voltage, full load and after warm-up)
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
Isolation
(kVDC)
R05P205S
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
UL/CSA and EN Safety certified
EN-61010 for Test, Measurement and Lab. Use
EN-60601 for Medical Applications
Standard Isolation 5.2kVDC
Optional Reinforced Isolation 6.4kVDC or 8kVDC
Optional Continuous Short Circuit Protected
Unique Transformer System (Patent Pending)
Compact SIP7 Package
Efficiency to 88%
Voltage
(VDC)
Input
3.3, 5V output types
other output types
(tested for 1 minute)
(rated for 1 minute)
(tested for 1 second)
(rated for 1 minute)
(tested for 1 second)
(rated for 1 minute)
Voltage Current
Output
Specifications valid for 10% minimum load only.
(VDC)
±3.3
±12
±15
3.3
±5
±9
12
15
5
9
R05P205D/R6.4, R05P205S/P/X2/R8
R05P205S/P, R05P205D/P
R05P205S/X2, R05P205S/P/X2
20kHz min. / 50kHz typ. / 85kHz max.
Output
±300
±200
±111
(mA)
±85
±66
600
400
222
167
132
REV: 1/2010
-40°C to +85°C (see Graph)
70-75 (79-84)
70-75 (80-87)
70-75 (80-87)
75-80 (80-88)
70-75 (79-85)
70-75 (80-87)
70-75 (80-87)
75-80 (80-88)
70 (72-78)
70 (73-80)
Efficiency
1.5pF min. / 10pF max.
Std (/R)
65% min. / 80% max.
(%)
1.2%/1% of Vin typ.
-55°C to +125°C
2600VAC / 60Hz
3200VAC / 60Hz
4000VAC / 60Hz
200mVp-p max.
15 GΩ min.
Continuous
15% max.
10% max.
5200VDC
6400VDC
8000VDC
1 Second
95% RH
Capacitive
±10%
±1500µF
±5%
±470µF
±470µF
±330µF
±330µF
cont.
3300µF
1200µF
1200µF
Load
680µF
680µF
Max
(1)
The RxxP2xxS_D Series of DC/DC Converters are
fcertified to UL/CSA-60950 and UL/CSA 60601. This
makes them ideal for medical and safety applications
where approved or reinforced isolation is required.
The reinforced versions are also EN61010-1 certified
for Lab Equipment. The /X2 version has an input/
output clearance of more than 9mm.
Derating-Graph
(Ambient Temperature)
Description
EN-60950-1 Certified
EN-60601-1 Certified
UL/CSA 60950-1 Certified
UL/CSA 60601-1 Certified
EN-61010-1 Certified (/R only)
RxxP2xx(R)
2002/95/EC
RoHS
6/6
ECONOLINE
DC/DC-Converter
with 3 year Warranty
2 Watt
SIP 7 Single &
Dual Output
www.recom-electronic.com
Refer to Application Notes
E-224736

Related parts for R24P215S/X2/R6.4

R24P215S/X2/R6.4 Summary of contents

Page 1

UL/CSA and EN Safety certified Features ● EN-61010 for Test, Measurement and Lab. Use ● EN-60601 for Medical Applications Unregulated ● Standard Isolation 5.2kVDC ● Optional Reinforced Isolation 6.4kVDC or 8kVDC Converters ● Optional Continuous Short Circuit Protected ● ...

Page 2

ECONOLINE DC/DC-Converter Tolerance Envelope Specifications ( Package Weight Packing Quantity MTBF (+25°C) . (+85°C) using MIL-HDBK 217F Reinforced Isolation Transformer Creepage Certifications Reinforced Part Measurement, Control and Laboratory Use Safety Certifications Standard Part Notes Note 1 Maximum capacitive load is ...

Page 3

ECONOLINE DC/DC-Converter Typical Characteristics RxxP212/15S RxxP212/15D Typical Characteristics - Reinforced Version RxxP205S/R6.4 RxxP205S/R8 RxxP205D/R6.4 RxxP205D/R8 E-62 RxxP2xxS_D (/Rx) Series REV:1/2010 www.recom-electronic.com ...

Page 4

ECONOLINE DC/DC-Converter Package Style and Pinning (mm) 7 PIN SIP Package www.recom-international.com RxxP2xxS_D (/Rx) Series Recommended Footprint Details ø ø REV:1/2010 Pin Connections Pin # Single Dual /X2 1 +Vin +Vin +Vin 2 -Vin -Vin -Vin 5 –Vout –Vout No ...