R05P12D/P/R6.4 Recom Power Inc, R05P12D/P/R6.4 Datasheet

no-image

R05P12D/P/R6.4

Manufacturer Part Number
R05P12D/P/R6.4
Description
CONV DC/DC 1W 05VIN +/-12VOUT
Manufacturer
Recom Power Inc
Series
ECONOLINE RxxPxx(/R)r
Type
Isolatedr
Datasheet

Specifications of R05P12D/P/R6.4

Operating Temperature
-40°C ~ 85°C
Power (watts) - Rated
1W
Efficiency
75 ~ 82%
Approvals
CSA, EN, UL
Output
±12V
Number Of Outputs
2
Power (watts)
1W
Mounting Type
Through Hole
Voltage - Input
5V
Package / Case
7-SIP Module (5 Leads)
1st Output
12 VDC @ 41mA
2nd Output
-12 VDC @ 41mA
Size / Dimension
0.77" L x 0.39" W x 0.49" H (19.5mm x 9.8mm x 12.5mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
www.recom-international.com
Selection Guide
Specifications (
Features
Unregulated
Converters
Part
Number Isolation
SIP 7
RxxP3.3S
RxxP05S
RxxP09S
RxxP12S
RxxP15S
RxxP3.3D
RxxP05D
RxxP09D
RxxP12D
RxxP15D
xx = Input Voltage. Other input and output voltage combinations available on request.
No suffux is functional isolation e.g,
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
* add Suffix “/X2” for single output with alternative pinout, e.g.
* add Suffix “/R6.4” or “/R8” for Reinforced Isolation, e.g.
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Output Ripple and Noise (20MHz BW)
Operating Frequency
Efficiency at Full Load
Minimum Load = 0%
Isolation Voltage Standard
/R6.4
/R8
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
P-Suffix
Operating Temperature Range (free air convection)
Storage Temperature Range
Relative Humidity
Package Weight
Packing Quantity
Standard Reinforced
(kVDC)
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
measured at T A = 25°C, nominal input voltage, full load and after warm-up)
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
Isolation
(kVDC)
R05P05S
UL/CSA and EN Safety certified
EN-61010 for Test, Measurement and Lab. Use
EN-60601 for Medical Applications
Standard Isolation 5.2kVDC
Optional Reinforced Isolation 6.4kVDC or 8kVDC
Optional Continuous Short Circuit Protected
Unique Transformer System (Patent Pending)
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
Voltage
(VDC)
Input
3.3, 5V output types
other output types
(tested for 1 second)
(rated for 1 minute)
(tested for 1 second)
(rated for 1 minute)
(tested for 1 second)
(rated for 1 minute)
Specifications valid for 10% minimum load only.
R05P05D/R6.4, R05P05S/P/X2/R8
Voltage Current
Output
(VDC)
±3.3
±12
±15
R05P05S/P, R05P05D/P
3.3
±5
±9
12
15
5
9
R05P05S/X2, R05P05S/P/X2
20kHz min. / 50kHz typ. / 85kHz max.
REV:1/2010
Output
±151
±100
(mA)
±55
±41
±33
303
200
111
84
66
-40°C to +85°C (see Graph)
4pF min. / 10pF max.
65% min. / 75% typ.
70-75 (75-80)
70-75 (75-82)
70-75 (75-82)
75-80 (75-83)
70-75 (75-82)
70-75 (75-82)
70-75 (75-82)
75-80 (75-83)
1.2%/1% of Vin typ.
70 (70~80)
70 (72-79)
Efficiency
-55°C to +125°C
Std (/R)
2600VAC / 60Hz
3200VAC / 60Hz
4000VAC / 60Hz
200mVp-p max.
25 pcs per Tube
(%)
15 GΩ min.
Continuous
15% max.
10% max.
5200VDC
6400VDC
8000VDC
1 Second
95% RH
±10%
±5%
cont.
4.3g
Capacitive
±1000µF
±470µF
±470µF
±220µF
±220µF
2200µF
1000µF
1000µF
Load
470µF
470µF
Max
(1)
The RxxPxxS_D Series of DC/DC Converters are
certified to UL/CSA-60950 and UL/CSA 60601. This
makes them ideal for medical and safety applications
where approved or reinforced isolation is required.
The reinforced versions are also EN61010-1 certified
for Lab Equipment Safety.
Derating-Graph
(Ambient Temperature)
Description
2002/95/EC
EN-60950-1 Certified
EN-60601-1 Certified
UL/CSA 60950-1 Certified
UL/CSA 60601-1 Certified
EN-61010-1 Certified (/R only)
RoHS
RxxPxx(/R)
6/6
ECONOLINE
DC/DC-Converter
with 3 year Warranty
1 Watt
SIP 7 Single
& Dual Output
Refer to Application Notes
E-224736
E-37

Related parts for R05P12D/P/R6.4

R05P12D/P/R6.4 Summary of contents

Page 1

UL/CSA and EN Safety certified Features ● EN-61010 for Test, Measurement and Lab. Use ● EN-60601 for Medical Applications Unregulated ● Standard Isolation 5.2kVDC ● Converters Optional Reinforced Isolation 6.4kVDC or 8kVDC ● Optional Continuous Short Circuit Protected ● ...

Page 2

ECONOLINE ECONOLINE DC/DC-Converter DC/DC-Converter Tolerance Envelope Specifications ( MTBF (+25°C) (+85°C) Reinforced Isolation Transformer Clearance PCB Creepage & Clearance Reinforced Types Certifications Reinforced Part Measurement, Control and Laboratory Use Safety Certifications Standard Part Notes Note 1 Maximum capacitive load is ...

Page 3

ECONOLINE ECONOLINE DC/DC-Converter DC/DC-Converter Typical Characteristics RxxP12/15S RxxP12/15D Typical Characteristics - Reinforced Version RxxP05S/R6.4 RxxP05S/R8 RxxP05D/R6.4 RxxP05D/R8 www.recom-international.com RxxPxxS_D (Rx) Series REV:1/2010 E-39 ...

Page 4

ECONOLINE ECONOLINE DC/DC-Converter DC/DC-Converter Package Style and Pinning (mm) 7 PIN SIP Package E-40 RxxPxxS_D (Rx) Series Recommended Footprint Details ø ø REV: 1/2010 Pin Connections Pin # Single Dual /X2 1 +Vin +Vin +Vin 2 -Vin –Vin –Vin 5 ...

Related keywords