LPS108-M Emerson Network Power, LPS108-M Datasheet

POWER SUP 48V 150W 2"X4" MED&ITE

LPS108-M

Manufacturer Part Number
LPS108-M
Description
POWER SUP 48V 150W 2"X4" MED&ITE
Manufacturer
Emerson Network Power
Series
LPS100-Mr
Datasheet

Specifications of LPS108-M

Operating Temperature
0°C ~ 50°C
Power (watts) - Rated
148.8W
Efficiency
88%
Approvals
CB, CE, CQC, cUL, TUV, UL
Line Regulation
±2%
Load Regulation
±2%
Voltage - Output
48V
Number Of Outputs
1
Power (watts)
150W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 3.1A
Size / Dimension
4" L x 2" W x 1.3" H (101.6mm x 50.8mm x 33mm)
Product
Switching
Commercial/medical
Both
Output Power Rating
168 W
Input Voltage
90 VAC to 264 VAC, 120 VDC to 300 VDC
Output Voltage (channel 1)
48 V
Output Current (channel 1)
3.5 A
Mounting Style
Chassis
Dimensions
101.6 mm L x 50.8 mm W x 33 mm H
Open Frame/enclosed
Open Frame
Power Supply Output Type
Fixed
No. Of Outputs
1
Input Frequency
63Hz
Output Voltage
48V
Output Current
3.1A
Power Rating
150W
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1473
LPS108-M

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPS108-M
Manufacturer:
EmersonN
Quantity:
250
Safety
• TUV
• UL
• cULus
• CB
• CE
• CQC
Total Power:
Input Voltage:
# of Outputs:
Special Features
• Medical and ITE safeties
• Active power factor correction
• 2” x 4” footprint
• Less than 1U high
• EN61000-3-2 compliant
• Remote sense
• Power fail
• Adjustable main output
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection
• Isolated12 V Fan output
• LPX50 Enclosure kit available
LPS100-M Series
150 Watts
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
Mark
80 - 150 Watts
90 - 264 Vac
Single
Electrical Specifications
Input
Input ra nge:
Frequency:
Inrush current:
Efficiency:
EMI/RFI:
Safety ground
leakage current:
Output
Maximum power:
Adjustment range:
Fan output:
Hold-up time:
Overload protection:
Overvoltage protection: 15-35% above nominal output
Logical Control
Power failure:
Remote sense:
90 - 264 Vac; 120 - 300 Vdc
47-63 Hz
50 A max., cold start @ 25 °C
88% typical at full load
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
275 µA @ 50/60 Hz, 264 Vac input
100 W for convection (80 W for LPS102-M);
150 W with 30 CFM forced air (120 W for LPS102-M)
± 10% minimum on the main outputs
12 V @ 1 A isolated, ± 10%
10 ms @ 150 W load, 120 Vac input
Short circuit protection on all outputs. Case overload
protected @ 110-160% above rating
Open collector logic signal goes high 100-500 msec after main output; it
goes low at least 6 msec before loss of regulation
Compensates for 0.5 V lead drop min. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 03.30.10_29
LPS100-M Series
1 of 3

Related parts for LPS108-M

LPS108-M Summary of contents

Page 1

LPS100-M Series 150 Watts Total Power 150 Watts Input Voltage 264 Vac # of Outputs: Single Special Features • Medical and ITE safeties • Active power factor correction • 2” x 4” footprint • Less than ...

Page 2

Environmental Specifications Operating temperature: 0° °C ambient derate each output as 2.5% per degree from 50° °C. -20 °C start up Storage temperature: -40 °C to +85 °C Electromagnetic Designed to meet EN61000-4; susceptibility: -2, -3, ...

Page 3

... LPS105 LPS108 Peak current lasting < 30 seconds with a maximum 10% duty cycle °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings Peak-to-peak with 20 mHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges ...

Related keywords