DS760SL-3 Emerson Network Power, DS760SL-3 Datasheet - Page 6

no-image

DS760SL-3

Manufacturer Part Number
DS760SL-3
Description
POWER SUPPLY AC/DC 12V 760W
Manufacturer
Emerson Network Power
Series
DS760r
Datasheet

Specifications of DS760SL-3

Operating Temperature
-10°C ~ 50°C
Power (watts) - Rated
748W
Efficiency
91%
Approvals
CB, CCC, CSA, cUL, UL, VDE
Line Regulation
1%
Load Regulation
1%
Voltage - Output
12V
Number Of Outputs
1
Power (watts)
760W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Rack Mount
1st Output
12 VDC @ 62.3A
Size / Dimension
12.68" L x 2.15" W x 1.57" H (322mm x 54.5mm x 40mm)
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Height (mm)
40mm
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2nd Output
-
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Compliant
Other names
454-1434
AC INPUT Present Indicator (ACOK#)
Status Indications
Normal Operation
V1 12 V Overcurrent
AC Input Fail
Fan Blocked or Running Under
Speed. O/P’s ok
UV on V1 12 V and PS Has Latched
Off
UV on Vsb +5.0 and PS Has
Turned Off
OV on V1 12V or Vsb +5.0 & PS
Has Latched Off
Over Temp and PS Has Turned Off
Fan Below Shutdown Limit
No Problems But PS is in Standby
Mode
Condition
The AC OK# signal is used to indicate presence of AC input to the power supply. This signal shall be connected to
5.0 Vsb through a resistor on the host system side. A logic “High” level on this signal shall indicate AC input to
the power supply is present. A Logic “Low” on this signal shall indicate a loss of AC input to the power supply.
See table below for Summary of Status signals, Ports and Indicators. The condition column assumes 2 or more
power supplies present and ON and 5.0 Vsb shared for management interface. On the “Fan Blocked” condition,
the assumption is that all outputs are within spec and not over temperature. This would be considered a “warn-
ing” condition. On the “Standby” condition, the system differentiates this state by knowing PS_ONL in negated
(requesting Standby).
Signal Type
Present = High
Present = Low
Logic level low voltage, Isink = 4 mA
Logic level high voltage, Isink = 50 µA
Sink current, PRESENT
Sink current, PRESENT
ACOK/H PWOK/H
Status Signals
#
#
1
1
0
1
1
1
1
1
1
1
= high
= low
ACOK
#
1
0
0
1
0
0
0
0
0
0
Signal Characteristics
Status Register
PSON
Status Indicators
1
1
1
1
1
1
1
1
1
0
Pull up to 5.0 Vsb through a resistor in
the host system.
PWOK
2.0 V
MIN
0V
1
0
0
1
0
0
0
0
0
0
Not Present
Fan-Fail
Present
0
0
0
0
0
0
0
1
0
0
AC-Loss
Shutdown Register
4.125 V
50 µsec
4 mA
0
0
1
0
0
0
0
0
0
0
0.8 V
MAX
0-Temp
0
0
0
0
0
0
0
1
0
0
Embedded Power for
Business-Critical Continuity
0-Current
0
1
0
0
0
0
0
0
0
0
Fail
0
1
1
0
1
1
1
1
1
0
On
On
Off
On
On
On
On
On
On
On
AC
LED’s
On
Off
Off
On
Off
Off
Off
Off
Off
Off
DC
Rev. 03.15.11_80
DS760SL Series
Fail
Off
Off
Off
Off
On
On
On
On
On
On
6 of 8

Related parts for DS760SL-3