Specifications of NPS28-M

Operating Temperature
0°C ~ 50°C
Power (watts) - Rated
40W
Efficiency
87%
Approvals
CE, CB, CQC, CSA, NEMKO, TUV, UL
Line Regulation
2%
Load Regulation
2%
Voltage - Output
48V
Number Of Outputs
1
Power (watts)
40W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 840mA
Size / Dimension
4.00" L x 2.00" W x 1.00" H (101.6mm x 50.8mm x 21.8mm)
Product
Switching
Commercial/medical
Both
Output Power Rating
25 W, 40 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 300 VDC
Output Voltage (channel 1)
48 V
Output Current (channel 1)
1 A
Mounting Style
Chassis
Dimensions
4 in L x 2 in W x 0.86 in H
Open Frame/enclosed
Open Frame
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
840mA
Power Rating
40W
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2nd Output
-
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1420
NPS20-M Series
40 Watts
Total Power:
Input Voltage:
# of Outputs:
Special Features
• Medical and ITE Safety Approvals
• Universal input
• Less than 1U high
• 2” x 4” footprint
• Remote sense
• Overload and short circuit
• Adjustable output voltage
• High efficiency
• High MTBF
• Built in EMI filter
• International Efficiency Level V,
• Less than 300 mW no-load
• 0˚C to +80˚C operation
• Input power < 49 watts
• Complies with EN61000 -3-2
• Class I approved
• Class II approved (with Class A
• LPX50 enclosure kit available
• Dual AC fuses
Safety
• TUV: 60950, 60601-1
• UL:
• CSA: 60950, 60601-1
• NEMKO: 60950, 60601-1
• CB:
• CE:
• CQC: Mark
protection
(CISPR 22 Class B)
Energy Star 2.0 & CeC compliant
(NPS22-M < 38 Watt output)
power consumption
EMI)
60950, 60601-1
Mark (LVD)
Certificate and report
25 - 40 Watts
90 - 264 VAC
127 - 300 VDC
Single
Electrical Specifications
Input
Input ra n ge:
Frequency:
Inrush current:
Input power:
Efficiency:
EMI/RFI:
Safety ground leakage
current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection: 30-50% above nominal output
Remote sense:
90 - 264 VAC (wide range) 127-300 Vdc
47 - 440 Hz
< 50 A peak @ 230 VAC, cold start @ 25 °C
< 49 Watts
87% average (as per Energy Star 2.0 standard) (NPS22-M, 80%)
FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B con-
ducted, VDE0878PT3 Class B conducted
275uA @ 50/60 Hz; 264 VAC input
25 W for convection. 40 W with 200LFM forced air
± 20% minimum (-10%, +20% for NPS22-M)
10/ 2 0 ms 115/230 VAC input line
Short circuit protection on all outputs. Case overload protected @
110-160% of normal rating, (110% - 190% for NPS28-M)
Compensated for 0.5 V lead drop max. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 11.15.10_132
NPS20-M Series
1 of 3

Related parts for NPS28-M

NPS28-M Summary of contents

Page 1

... Output Maximum power for convection with 200LFM forced air ± 20% minimum (-10%, +20% for NPS22-M) Adjustment range: Hold-up time: 10 115/230 VAC input line Overload protection: Short circuit protection on all outputs. Case overload protected @ 110-160% of normal rating, (110% - 190% for NPS28-M) Overvoltage protection: 30-50% above nominal output Remote sense: Compensated for 0.5 V lead drop max. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Rev. 11.15.10_132 NPS20-M Series ...

Page 2

Environmental Specifications 0° °C ambient derate each output at 2.5% per degree from 50° °C. -20 °C start up Operating temperature: Storage temperature: -45 °C to +85 °C Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 90% RH Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated: > 550,000 hours at full load and 25 °C ambient conditions Mechanical Drawing M1 GND TAB (CN1) PIN 1 INPUT CONNECTOR (SK1) PIN 2 Ø (4.0) MOUNTING HOLE (4 PLACES) 0.197” (5.0) MINIMUM STANDOFF HEIGHT 4.00" (101.6) 3.73" (94.6) ...

Page 3

... West Midlands, DY5 1LX United Kingdom ± 2% 480 mV Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 NPS28-M Line For global contact, visit: Neutral www.Emerson.com/EmbeddedPower techsupport.embeddedpower +48 V @emerson.com +48 V Common While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Common Network Power assumes no responsibility, and disclaims ...