TRIPLE O/P 3X5 5V/25A 12V/5A

NV1350TT

Manufacturer Part NumberNV1350TT
DescriptionTRIPLE O/P 3X5 5V/25A 12V/5A
ManufacturerTDK Corporation
SeriesNV175
TypeMedical
NV1350TT datasheets
 


Specifications of NV1350TT

Power Supply TypeSwitching (Open Frame)Operating Temperature0°C ~ 70°C
Power (watts) - Rated175WEfficiency90%
ApprovalsCE, CSA, EN, IEC, ULLine Regulation1%
Load Regulation1%Voltage - Output5V, ±12V
Number Of Outputs3Power (watts)175W
ApplicationsCommercialVoltage - Input90 ~ 264VAC
Mounting TypeChassis Mount1st Output5 VDC @ 25A
2nd Output12 VDC @ 5A3rd Output-12 VDC @ 1A
Size / Dimension5" L x 3" W x 1.25" H (127mm x 76.2mm x 31.8mm)Power Supply Output TypeFixed
No. Of Outputs3Output Voltage5V
Output Current25APower Rating175W
Input Voltage90V AC To 264V ACLength127mm
Width76.2mmBrand/seriesNV135 Series
ConfigurationOpen-FrameCurrent, Input25 A
Current, Leakage300 uA (Max.) @ 264 VAC⁄63 HzFrequency47 to 63 Hz
OperationLinearOutput-12 VDC @ 1 A, +5 VDC @ 25 A, +12 VDC @ 5 A
Power, Output175 WPrimary TypeAC-DC
Special FeaturesPFC, Remote SenseStandardsUL Listed, CSA Cerified, EN and IEC Approved
Temperature, Ambient0 °CVoltage, Input90 to 264 VAC
Voltage, Output-12, +5, +12 VDCLead Free Status / RoHS StatusLead free / RoHS Compliant
4th Output-  
1
Page 1
2
Page 2
Page 1/2

Download datasheet (100Kb)Embed
Next
F e a t u r e s a n d B e n e f i t s
Feature
High Efficiency
Low Profile
Power Factor Corrected
No Minimum Loads
S p e c i f i c a t i o n s
MODEL
ITEMS
Input Voltage range
-
Inrush Current
A
Power Factor Harmonics
-
Line Regulation
-
Load Regulation
-
Cross Regulation
-
Ripple & Noise
mV
Efficiency
-
Minimum Load
A
Overcurrent Protection
-
Overvoltage Protection
V
Overtemperature Protection
-
Hold Up Time (Typ)
ms
Leakage Current (max)
mA
Remote Sense
-
DC Good (Specify N option)
-
Remote On/Off (Specify N option)
-
Operating Temperature
-
Storage Temperature
-
Humidity (non condensing)
-
Cooling
-
Isolation
-
Vibration (non operating)
-
Shock
-
Safety Agency Approvals
-
Immunity
-
Conducted Emissions and Flicker
-
Radiated Emissions
-
Weight (Typ)
g
Size
(3)
in
Warranty
yrs
Notes: (1) -20°C cold start
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
NV175 Series
3” x 5” 175W Multiple Output Power Supplies
Up to 90% Efficient
Active Power Factor Correction
Universal Input (90 - 264VAC)
Up to 5 Outputs
No Minimum Loads
Medical Approvals
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Broadcast
Test & Measurement
Medical
Industrial Computing and Routers
Benefit
Less heat dissipated in system
Fits in 1U enclosures
Supports Global Use
Ease of Use
NV175
90 - 264VAC (47 - 63Hz, 440Hz with reduced PFC)
<40A at 25C and 264VAC input, Cold Start
EN61000-3-2 Compliant
< 0.1%
< 1%
< 0.1% for 100% load change on any output
CH1 & CH2: 50mV, CH3 & CH4: 1%
Up to 90%, configuration dependant
None
>105%
CH1 & CH2, 120-130%, Cycle AC line to reset
>16ms at 90VAC Input
0.3mA at 264VAC, 63Hz
On Outputs CH1 & CH2, 0.5V compensation maximum
CH1 Only, High on Fail (<97% of nominal)
TTL logic level low will enable all outputs
0 to +70°C. Derate linearily to 50% load from 50°C to 70°C(1)
-40 to +85°C
5 - 95% RH
Forced air, 2m/s from input to output
Input to Ground 2.3kVDC, Input to Output 4.3kVDC, Output to Ground 200VDC
2G, 10-500Hz (sweep & endurance at resonance) in all 3 planes
30G per IEC68-2-27
UL60950-1, CSA22.2 No 60950-1, EN60950-1, IEC60950-1, CE for LVD,
UL2601 EN60601, UL61010-1, EN61010-1, IEC61010
EN50082-2: EN61000-4-2, -3, -4, -5, -6, -8, -11
EN55022 Class B (per CISPR.22), EN61000-3-3
EN55022 Class A (per CISPR.22)(2)
250g
3” x 5” x 1.25” (3.7” x 5” x 1.25” for N option version)
Three Years
(2) See application note for Class B
Yes
(3) Including underside component leads

NV1350TT Summary of contents

  • Page 1

    Feature High Efficiency Low Profile Power Factor Corrected No Minimum Loads ...

  • Page 2

    ... NV1452TTN +5V/25A +2.7V/15A +12V/ 5.5V) (0.9 - 3.3V) (12 - 15V) NV1452FFN +5V/25A +2.7V/15A +15V/ 5.5V) (0.9 - 3.3V) (12 - 15V) NV1350TTN +5V/25A - +12V/ 5.5V) (12 - 15V) NV1350FFN +5V/25A - +15V/ 5.5V) (12 - 15V) Notes: (4) Maxium total current from CH1 & CH2 = 25A (5) CH5 is a standby Voltage (always On). 2.5A Peak rated ...