LPT104-M Emerson Network Power, LPT104-M Datasheet

PWR SUP MED 5V 24V 12V 130W 2X4"

LPT104-M

Manufacturer Part Number
LPT104-M
Description
PWR SUP MED 5V 24V 12V 130W 2X4"
Manufacturer
Emerson Network Power
Series
LPT100-Mr
Datasheet

Specifications of LPT104-M

Operating Temperature
0°C ~ 50°C
Power (watts) - Rated
130W
Efficiency
82%
Approvals
AUSTEL, CB, CE, CSA, NEMKO, TUV, UL
Line Regulation
±2%, ±5%, ±7%
Load Regulation
±2%, ±5%, ±7%
Voltage - Output
5V, 12V, 24V
Number Of Outputs
3
Power (watts)
130W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 18A
2nd Output
24 VDC @ 3A
3rd Output
12 VDC @ 2.3A
Size / Dimension
4" L x 2" W x 1.28" H (102mm x 51mm x 32.6mm)
Output Power Rating
10 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 300 VDC
Output Voltage (channel 1)
5 V
Output Current (channel 1)
2 A
Output Voltage (channel 2)
24 V
Output Current (channel 2)
3.5 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
2 A
Mounting Style
Chassis
Power Supply Output Type
Variable
No. Of Outputs
3
Input Frequency
63Hz
Output Voltage
5V
Output Current
18A
Power Rating
130W
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1480
LPT104-M
Safety
• TUV 60950, 60601-1
• UL
• CSA
• NEMKO
• AUSTEL
• CB
• CE
Total Power:
Input Voltage:
# of Outputs:
Special Features
• Medical and ITE safeties
• Active power factor correction
• 2” x 4” footprint
• Less than 1U high
• EN61000-3-2 compliant
• Remote sense
• Power fail
• Adjustable main output
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection
• LPX50 enclosure kit available
LPT100-M Series
130 Watts
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
60950, 60601-1
80 - 130 Watts
90 - 264 Vac
Triple
Electrical Specifications
Input
Input ra n ge:
Frequency:
Inrush current:
Efficiency:
EMI/RFI:
Safety ground
leakage current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection: 15 - 35% above nominal output
Logical Control
Power failure:
Remote sense:
90 - 264 Vac; 127 - 300 Vdc
47 - 63 Hz
50 A max., cold start @ 25 °C
82% typical at full load
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
2 75 µA @ 50/60 Hz, 264 Vac input
80 W for convection;
130 W with 200 LFM forced air
All outputs adjustable: -20%, +10%, except for +24V output on LPT104-M
which will be -10%, +20% and 3.3 V output on the LPT101-M +10%, -15%
10 ms @ 130 W load, 120 Vac input
Short circuit protection on all outputs. Case overload
protected @ 110 - 160% above rating for V1 & V2, 150 - 250% for V3
Active LowTTL logic signal goes high 100 - 500 msec after main output; it
goes low at least 6 msec before loss of regulation
C ompensates for 0.5 V lead drop min. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 01.14.11_141
LPT100-M Series
1 of 3

Related parts for LPT104-M

LPT104-M Summary of contents

Page 1

... Safety ground 2 75 µA @ 50/60 Hz, 264 Vac input leakage current: Output Maximum power for convection; 130 W with 200 LFM forced air Adjustment range: All outputs adjustable: -20%, +10%, except for +24V output on LPT104-M which will be -10%, +20% and 3.3 V output on the LPT101-M +10%, -15% Hold-up time 130 W load, 120 Vac input Overload protection: Short circuit protection on all outputs. Case overload protected @ 110 - 160% above rating for V1 & V2, 150 - 250% for V3 Overvoltage protection 35% above nominal output ...

Page 2

Environmental Specifications Operating temperature: 0° °C ambient derate each output as 2.5% per degree from 50° °C. -20 °C start up Storage temperature: -40 °C to +85 °C Electromagnetic designed to meet EN61000-4; susceptibility: -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10% - 95% Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF calculated: 583,000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore Mechanical Drawing GND PIN 1 (LIVE) PIN 3 (NEUTRAL) SK1 Output Voltage Adjust Pots SK3 SK2 Mounting Hole ø 0.16” [4.0] 4 Places Max. Screw Head ...

Page 3

... Voltage Load Cooling +3 LPT101 + + LPT102-M - LPT103 LPT104 Peak current lasting < 15 seconds with a maximum 10% duty cycle °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings Peak-to-peak with 20 mHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. Pin Assignments Connector LPT100-M SK1 PIN 1 Neutral PIN 3 Line SK2 PIN 1 V1out PIN 2 V1out PIN 3 GND PIN 4 GND ...

Related keywords