CD4850D2UH Crydom Co., CD4850D2UH Datasheet

RELAY SSR DUAL 50A ZERO PNL MNT

CD4850D2UH

Manufacturer Part Number
CD4850D2UH
Description
RELAY SSR DUAL 50A ZERO PNL MNT
Manufacturer
Crydom Co.
Datasheets

Specifications of CD4850D2UH

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Evolution Dual Series
PRODUCT SELECTION
Control Voltage
4-15 VDC
15-32VDC
4-32 VDC
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Load Current Range (3) [Arms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Surge Current 60Hz (16.6ms) [Apk]
Maximum Surge Current 50Hz (20ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I²t for Fusing (8.3 msec) [A² sec]
Maximum I²t for Fusing (10 msec) [A² sec]
Minimum Power Factor (with Maximum Load)
240V,25A
CD2425W1U
CD2425D1U
CD2425E1U
• 100K cycle UL508 Endurance Rating
• 25A & 50A Output rating per channel @ 40°C
• 24 to 280 & 48 to 600VAC Operating voltage
• 4-15, 15-32 & 4-32VDC Control input options
• Four input termination options
• Zero-crossing (resistive loads) or random-fire (inductive loads)
• Input status LED indicator for each channel
• Available with IP20 “Touch-Safe” Covers
output
Cx2425xxxx
240V, 50A
CD2450W1U
CD2450D1U
CD2450E1U
0.15-25
24-280
0.65
600
500
300
275
370
380
1.0
1.3
0.5
Cx2450xxxx
0.15-50
24-280
2320
2520
0.33
600
500
750
710
1.0
1.3
0.5
480V, 25A
CD4825W1U
CD4825D1U
CD4825E1U
Cx4825xxxx
0.15-25
48-600
1200
0.65
500
300
275
370
380
1.0
1.3
0.5
480V, 50A
CD4850W1U
CD4850D1U
CD4850E1U
Cx4850xxxx
0.15-50
48-600
1200
2320
2520
0.33
500
750
710
1.0
1.3
0.5

Related parts for CD4850D2UH

CD4850D2UH Summary of contents

Page 1

Evolution Dual Series PRODUCT SELECTION Control Voltage 240V,25A 4-15 VDC 15-32VDC 4-32 VDC CD2425W1U AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-63Hz) [Vrms] Load Current Range (3) [Arms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] ...

Page 2

INPUT SPECIFICATIONS (1) Description Control Voltage Range Minimum Turn-On Voltage Minimum Turn-Off Voltage Typical Input Current Nominal Input Impedance Maximum Turn-On Time [msec] (4) Maximum Turn-Off Time [msec] GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output (50/60Hz) Dielectric Strength, Input/Output/Base (50/60Hz) Minimum ...

Page 3

MECHANICAL SPECIFICATIONS ...

Page 4

THERMAL DERATE INFORMATION AGENCY APPROVALS E116950 Rev. 111810 ...

Page 5

...

Page 6

ANNEX - ENVIROMENTAL INFORMATION ...

Related keywords