CB-ACC-53 ConnectBlue, CB-ACC-53 Datasheet

no-image

CB-ACC-53

Manufacturer Part Number
CB-ACC-53
Description
ANTENNA DUAL-BAND RPSMA
Manufacturer
ConnectBlue
Datasheet

Specifications of CB-ACC-53

Antenna Type
Whip: 1/2 Wave, Swivel, Tilt (Right Angle)
Number Of Bands
2
Frequency
2.4GHz, 5GHz
Gain
3dBi
Termination
RP-SMA
Mounting Type
Connector
Height (max)
4.21" (107mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
809-1035
INDUSTRIAL BLUETOOTH™
OEM Serial Port Adapter™
cB-OEMSPA311 / 331, cB-0901
Electrical & Mechanical Datasheet

Related parts for CB-ACC-53

CB-ACC-53 Summary of contents

Page 1

... OEM Serial Port Adapter™ cB-OEMSPA311 / 331, cB-0901 Electrical & Mechanical Datasheet INDUSTRIAL BLUETOOTH™ ...

Page 2

... OEM Serial Port Adapter™ Electrical & Mechanical Datasheet cB-0901 ...

Page 3

... All rights reserved. Release: 2009-12 Document version: 1.16 Document number: cBProduct-0410-04 Printed in Sweden. Trademarks Registered trademarks from other companies are: Bluetooth is a trademark owned by the Bluetooth SIG, Inc., Microsoft™, Windows™, Windows NT™, Windows 2000™ ...

Page 4

... Mounting Information 5.1 Board Outlines .................................................................................30 5.2 Using the J2/J3 Board-to-Board Connectors ...................................32 5.3 Using Press-Fit Nuts for Mounting the Module ................................36 5.4 Using the J6 PCB solder pads on the edge.....................................36 5.5 Antenna Issues ................................................................................37 6 Bluetooth Information 6.1 General information .........................................................................38 6.2 Bluetooth Qualification information ..................................................39 7 Regulatory Information 7 ...

Page 5

... The resistance value of the pull-down resistors needs to be decreased to 1kΩ especially important to be observant on the Mode and Switch-1 signals. This point is not necessary for the cB-OEMSPA333 modules and 10kΩ can still be used. See the LED and Switch Design Examples for more info. ...

Page 6

... Product Variants This Electrical and Mechanical datasheet contains information about the 12 variants of OEM Se- rial Port Adapters based on the PCB cB-0901. This document makes references to the OEM Module ID, not the Product Name (see Table 1). Table 1: Product variants Product Name OEM Module ID ...

Page 7

... Bluetooth module based on the Phillips BGB203 system in package (SiP). The BGB203 has on chip SRAM and FLASH stacked in the same package. The modules are available in many variants with different antenna / connectors and output power combinations. See Picture 1 - Picture 3 for some of the available models. All models are described in Table 1. ...

Page 8

... Block Diagram cB-0901 Figure 1: Block diagram of cB-0901 Version 1.16 - 2009-12 8 ...

Page 9

... This section describes the signals available on the module interface connectors. There are four ways to connect to the OEM Serial Port Adapter: • Via the PCB solder pads on the edge of the PCB, J6 (see Picture 4). See Section 5.4 for more information. • Via the 2x20-pin 1mm pitch board-to-board (one piece part) connectors, J2 through J3. ...

Page 10

... Pin Numbering 2.1.1 J2, J3 and J6 Connectors Figure 2: Bottom view of the PCB with the pinning of the J2, J3 and the J6 connector. 2.1.2 JST 6-pol, J8 Figure 3: Top view of the PCB with the pinning of the J8 connector. 2.1.3 Flexfilm, J7 Figure 4: Top view of the PCB with the pinning of the J7 connector. ...

Page 11

... In/Out RED: Logic Red LED Signal (see Chapter 3, Table 14). Active low. Mode: Not used on cB-0901. This pin is also used to select Logic level mode (instead of RS232) for connectBlue product with internal RS232 driver compatible with these products check the datasheet for these products about this signal. ...

Page 12

... Receive Data 19 UART-DTR* Data Terminal Ready 20 UART-DSR* Data Set Ready * All signals are logic level UART signals (typically 0 - 3VDC) ** Use 1kΩ as pull-down which is different to previous product generations from connectBlue Version 1.16 - 2009-12 Signal Type Description Level CMOS In/Out This signal is multiplexed: ...

Page 13

J3 Connector Table 3: Signals Pin Name Signal Name Pin Nr 1-8 9 SerialSelect-0 Serial Select 0 10 SerialSelect-1 Serial Select 1 11-18 RESET 19 Hardware reset 20 Version 1.16 - 2009-12 Signal Type Description Level ...

Page 14

... Out RED: Logic Red LED Signal (see Chapter 3, Table 14). Active low. Mode: Not used on cB-0901. This pin is also used to select Logic level mode (instead of RS232) for connectBlue product with internal RS232 driver compatible with these products check the datasheet for these products about this signal ...

Page 15

J6 Pin Name Signal Name Pin Nr 6 GREEN/ Green LED output and Switch-1 Restore switch 7 BLUE Blue LED output 8 UART-CTS* Clear To Send 9 UART-TxD* Transmit Data 10 UART-RTS* Request To Send 11 UART-RxD* Receive Data 12-15 ...

Page 16

... SerialSelect-0 Serial Select 0 18 SerialSelect-1 Serial Select 1 19-22 Attachment pads * All signals are logic level UART signals (typically 0 - 3VDC) ** Use 1kΩ as pull-down which is different to previous product generations from connectBlue Version 1.16 - 2009-12 Signal Type Description Level CMOS In Active low. Also used to control the power saving mode “ ...

Page 17

... Out RED: Logic Red LED Signal (see Chapter 3, Table 14). Active low. Mode: Not used on cB-0901. This pin is also used to select Logic level mode (instead of RS232) for connectBlue product with internal RS232 driver compatible with these products check the datasheet for these products about this signal ...

Page 18

... Receive Data 11 UART-CTS* Clear To Send 12 UART-RTS* Request To Send 13-16 * All signals are logic level UART signals (typically 0 - 3VDC) ** Use 1kΩ as pull-down which is different to previous product generations from connectBlue Version 1.16 - 2009-12 Signal Type Description Level CMOS In/Out This signal is multiplexed: GREEN: Logic Green LED Signal (see Chapter 3, Table 14) ...

Page 19

... Signal Type Description Level Ground GND 3.3V 3.0 – 6.0 VDC for CB-OEMSPA311 modules 3.3 – 6.0 VDC for CB-OEMSPA331 modules CMOS Out “0” : Low, “1” : High CMOS In “0” : Low, “1” : High CMOS In Hardware flow control. Active low. ...

Page 20

... If you design your power supply for cB-OEMSPA331i/x the modules will be fully interchangeable. The cB-0901 module has a linear power supply, which means that the current is constant if the voltage supply is changed. See Table 10. For more information about low power modes see Serial Port Adapter AT commands Specifica- tion ...

Page 21

... Table 9: Power supply Symbol Parameter VCC_3V3 Power supply (Un- regulated*) * The module is equipped with an internal linear voltage regulator. Table 10: Current consumption Symbol Mode I Not connected CC Stop mode not enabled. @ VCC_3V3 = 3.3V Not con- Not connectable nected, stop mode en- ...

Page 22

... Logic LOW level output voltage OUT V High Logic HIGH level output voltage OUT I Sink and source current GPIO 2.3.2.2 cB-OEMSPA331i/x products Table 12: Input/output signals Symbol Parameter V Low Logic LOW level input voltage on all logic IN input pins except Switch-0 Logic LOW level input voltage Switch-0 ...

Page 23

... Table 13: Temperatures characteristics Parameter Storage temperature Maximum operating temperature Version 1.16 - 2009-12 Product Variant Value Min All Max All +125 Min CB-OEMSPA311i/x-04 CB-OEMSPA331i/x-04 CB-OEMSPA311i/x-07 CB-OEMSPA331i/x-07 CB-OEMSPA311i/x-06 CB-OEMSPA331i/x-06 Max CB-OEMSPA311i/x-04 CB-OEMSPA331i/x-04 CB-OEMSPA311i/x-06 CB-OEMSPA331i/x-06 CB-OEMSPA311i/x-07 CB-OEMSPA331i/x-07 Unit °C -40 °C °C -30 °C -25 °C +85 °C +80 23 ...

Page 24

Hardware Reset A hardware input is available on the J3, J6 and J7 connectors (see section 2.1). An ex- RESET ternal reset source must be open drain collector, see section A.2.4 for design examples. The pin is internally pulled-up ...

Page 25

Operating Status The module can be in different modes (see the Serial Port Adapter AT command Specification for more information about the modes) and the RED, GREEN and BLUE signals can be used to detect or indicating the status, ...

Page 26

... Rufa 2.4 GHz Manufacture gigaAnt Polarization Linear Gain (Max) +0.5 dBi (mounted on this PCB) Antenna size 12.8x3.9x1.1 mm (LxWxH) Comment The antenna gain is very dependent of the mounting of the module. See section 5.4 for mounting the module considering the antenna. Version 1.16 - 2009-12 ...

Page 27

... SMA female Cable length 120 mm Cable loss Less than 0.5dB Comment The SMA connector may be mounted in a panel. Not approved for use in the US and Canada. Part Number cB-ACC-38 Name U.FL to Reverse Polarity SMA adapter cable Connector U.FL and reverse polarity SMA male ...

Page 28

... Approved for use in the US, Canada and Europe. Part Number cB-ACC-27 Name WCR-2400-IP04 Manufacture Centurion Type ½ wave dipole Polarization Vertical Gain +2.0dBi Size 108 mm (Straight) Connector U.FL connector Comment To be mounted on the U.FL connector on the PCB. Approval Approved for use in the US and Canada Version 1.16 - 2009-12 28 ...

Page 29

... Polarization Vertical Gain 0dBi Connector SMA male Comment To be mounted on the U.FL to SMA adapter cable Approval Not approved for use in the US and Canada. Part Number cB-ACC-21 Name Rugged SMA Manufacture Radiall/Larsen Type ½ wave dipole Polarization Vertical Gain 2dBi Connector ...

Page 30

... Mounting Information 5.1 Board Outlines 5.1.1 cB-0901 Figure 5: cB-0901 dimensions [mm]. The J2 pads are longer to fit both the single and double row ASP con- nectors (see section 5.2). Some of the not used pads of J3 are not visible Version 1.16 - 2009-12 30 ...

Page 31

... Mounting Holes There are 2 x 2.3mm mounting holes on cB-0901. The reasons for the 2.3mm holes are that the threaded M2 holes on the single and double row connectors (see section 5.2.1) are not aligned. The outer tangents of the 2.3mm holes align the module if the single row connectors are used and the inner if double row connectors are used (see Figure 6) ...

Page 32

... SEI-120-02-GF-S-M-AB-TR NOTE: When ordering connectors from Samtec or an official Samtec distributor, please use the ASP or- der number and refer to the connectBlue global quote number for best price. For technical questions regarding the Samtec connectors please contact connectBlue or Samtec at (Scandinavia@samtec.com). See Figure 7 for more information about the connector and necessary measurements on the motherboard ...

Page 33

... Figure 7: Host PCB layout [mm] for single row connector. Version 1.16 - 2009-12 33 ...

Page 34

... FSI-120-03-G-D-M-AB-K-TR NOTE: When ordering connectors from Samtec or an official Samtec distributor, please use the REF or- der number and refer to the connectBlue global quote number for best price. For technical questions regarding the Samtec connectors please contact connectBlue or Samtec at (Scandinavia@samtec.com). See Figure 8 for more information about the connector and necessary measurements on the motherboard ...

Page 35

... Figure 8: Host PCB layout [mm] for double row connector. Version 1.16 - 2009-12 35 ...

Page 36

... Using Press-Fit Nuts for Mounting the Module A press-fit nut is pressed into the PCB from the bottom side with a special press tool. M2 sized press-fit nuts are suitable for the modules (see Figure 7 and Figure 8) and are manufactured by PEM Fastening Systems (www.pemnet.com), part no KFS2-M2 (see Figure 9). Be careful with the distance between the nuts regarding alignment, see section 5 ...

Page 37

... Antenna Issues The unit cannot be mounted arbitrary, because of the radio communication. The unit with an internal surface mounted antenna (CB-OEMSPA311i and CB-OEMSPA331i) cannot be mounted in a metal enclosure, see Figure 10. No metal casing or plastics using metal flakes should be used, avoid also metallic based paint or lacquer ...

Page 38

... General information In the tables below you can find information about Bluetooth properties. The cB-0901 module is available in two output power versions both Bluetooth Class 1. The output power of the cB- OEMSPA311i/x device is max +7dBm (5mW) and the output power of the cB-OEMSPA331i/x device is max +16.9dBm (49mW). ...

Page 39

... Bluetooth Qualification information All products based on the PCB cB-0901-03 have been qualified according to the Bluetooth specification 2.0. Table 19 - Bluetooth Qualification information Module Bluetooth specification cB-OEMSPA311i /x 2.0 cB-OEMSPA331i/x 2.0 The following Bluetooth profiles are supported (covered functionality): • Generic Access Profile (GAP) • ...

Page 40

... Malmö, Sweden Mats Andersson CTO of connectBlue cB-OEMSPA331i/x is used within EU a notification must be made to each of the national au- thorities responsible for radio spectrum management of the intention to place radio equip- ment that uses frequency bands whose use is not harmonized throughout the EU, on its na- tional market ...

Page 41

... Consult the dealer or an experienced radio/TV technician for help 7.3.1.1.1 Antenna Our module type cB-0901-0301 is for OEM integrations only. The end-user product will be pro- fessionally installed in such a manner that only the authorized antennas are used. 7.3.1.1.2 Caution Any changes or modifications NOT explicitly APPROVED by connectBlue AB could cause the module to cease to comply with FCC rules part 15, and thus void the user’ ...

Page 42

... RF field in excess of Health Canada limits for the general population; con- sult Safety Code 6, obtainable from Health Canada’s website www.hc-sc.gc.ca/rpb. 7.3.1.3 Labeling Requirements for End Product For an end product using the product cB-0901-0301 there must be a label containing, at least, the following information: This device contains ...

Page 43

... Consult the dealer or an experienced radio/TV technician for help 7.3.2.1.1 Antenna Our module type cB-0901-0302 is for OEM integrations only. The end-user product will be pro- fessionally installed in such a manner that only the authorized antennas are used. 7.3.2.1.2 Caution Any changes or modifications NOT explicitly APPROVED by connectBlue AB could cause the module to cease to comply with FCC rules part 15, and thus void the user’ ...

Page 44

... Labeling Requirements for End Product For an end product using the product cB-0901-0302 there must be a label containing, at least, the following information: This device contains FCC ID: PVH090103L IC: 5325A-090103L The label must be affixed on an exterior surface of the end product such that it will be visible upon inspection in compliance with the modular approval guidelines developed by the FCC. In accordance with 47 CFR § ...

Page 45

... UL recognized ZPMV2 min. 105 °C flame class V-0 or better. 7.6 Compliance with RoHS directive All products based on the PCB cB-0901-03 are produced according to the RoHS (Restriction of the use of certain Hazardous Substances in electrical and electronic equipment) directive and complies with the directive. ...

Page 46

... For any exceptions, due to national requirements or limitations, when using your OEM Serial Port Adapter, please visit www.bluetooth.org. Note: Changes or modifications to the product not expressly approved by connectBlue AB will void the user’s authority to operate the equipment. 8.2 Product Care • Do not expose your product to liquid or moisture. ...

Page 47

Electronic Equipment Most modern electronic equipment, for example, in hospitals and cars, is shielded from RF en- ergy. However, certain electronic equipment is not. Therefore: Note: This equipment emits RF energy in the ISM (Industrial, Scientific, Medical) band. Please ...

Page 48

Appendix A - Usually only a subset of the available functionality is of interest to the designer. In addition, de- pending on the host system, the electrical interface can be designed in many ways. The designer can use the step-by-step ...

Page 49

A.2 Design Examples This section contains design examples for all interfaces on J2, J3, J6, J7 and J8. The connector type that suits a specific application depends on the needed signal and the preferred interface type (wires, flexfilm, board-to-board or ...

Page 50

A.2.2 Serial Interface The serial interface of the module is Logic Level logic levels and the module can be connected to an external CPU (see section A.2.2.1). An external driver is needed if the module should be on another physical ...

Page 51

A.2.2.2 External RS232 driver An external RS232 driver is needed if the module should have a RS232 serial interface. See Figure 16 for a complete design example that could be connected to the serial port of standard PC. Not used ...

Page 52

A.2.2.4 External RS422/RS485 transceiver A complete RS422/RS485 transceiver design connected to a bus system need to control the en- able signals of the transceiver. The SerialSelect signals are used for this purpose (see Table 21). The module need to be ...

Page 53

A.2.3 LED and Switch Design A.2.3.1 BLUE Signal The BLUE logic LED signal is not multiplexed with any other functionality, which makes the de- sign more straightforward (for more information see Figure 19). There are two important notes ...

Page 54

... The RED signal pin is also used to select Logic Level mode (instead of RS232) for connectBlue product with internal RS232 driver. The mode functionality is not applicable on cB-0901 because there is no internal RS232 driver available compatible with these products check the data- sheet about this signal ...

Page 55

... The signal is internally pulled-up (16kΩ) to 3.0V for NOT restoring settings to default. Note! The internal 16kΩ Ω Ω Ω pull-up is smaller than on previous product generations from connectBlue. This requires a smaller pull-down resistor (1kΩ Ω Ω Ω ) for a low state LED is used and a switch is required to be able to restore the settings, a high impendence buffer need to prevent the signal from being pulled-up via the LED ...

Page 56

Figure 25: No restore switch used but a green LED in a 3.3V host system. The status of the signal can also be used as input to a host con- troller. A serial resistor to the restore switch must be ...

Page 57

A.2.4 Reset RESET The pin can be connected to an external reset source, see Figure 31 for a switch exam- ple. If the reset signal is connected to an output signal it must be an open drain collector, see Figure ...

Page 58

A.2.5 A Complete 5V Host System Interface This is a complete 5V host system interface example with an RGB LED and two switches (except the serial interface, see section A.2.2 for information). The design is based on the LM339 Quad ...

Related keywords