2002-0992 WAGO, 2002-0992 Datasheet

END PLATE, TOPJOB TERMINAL BLOCK

2002-0992

Manufacturer Part Number
2002-0992
Description
END PLATE, TOPJOB TERMINAL BLOCK
Manufacturer
WAGO
Series
TOPJOBr
Datasheet

Specifications of 2002-0992

Color
Orange
Accessory Type
End Plate
Rohs Compliant
Yes
For Use With
TOPJOB Fuse Disconnect Terminal Blocks
?
Fuse Terminal Blocks for Blade-Type Fuses
acc. to DIN 72581-3f, ISO 8820-3, Series 2002
0.25
400 V/6 kV/3
I
Terminal block width 5.2 mm / 0.205 in
L 10 — 12 mm / 0.43 in
2-conductor fuse terminal blocks
gray
Article-specific accessories
End and intermediate plate, 1 mm/0.039 in thick
Accessories Series 2002
Insulation stop, 5 pcs/strip
Push-in type jumper bars, light gray, insulated, I
Push-in type jumper bars, light gray, insulated, I
Modular TOPJOB
Spacer, modular
Blade-type fuses acc. to DIN 72581-3f /
ISO 8820-3 (not offered by WAGO)
N
- Block arrangement: 5 A
Please note touchproof protection from 42 V
10 A
- Individual arrangement: 10 A
— 2.5 (4) mm
<________ 66,5 mm /2.61 in ________>
®
S connector,
Item no.
2002-1681
orange 2002-1692 100 (4 x 25)
gray
light gray 2002-171 0.25-0.5 mm
dark gray 2002-172 0.75-1 mm
10-way 2002-410 100 (4 x 25)
for jumper contact slot
1 pole 2002-511 100 (4 x 25)
2002-549
2-way 2002-402 200 (8 x 25)
3-way 2002-403 200 (8 x 25)
4-way 2002-404 200 (8 x 25)
5-way 2002-405 100 (4 x 25)
1 - 3 2002-433 200 (8 x 25)
1 - 4 2002-434 200 (8 x 25)
1 - 5 2002-435 100 (4 x 25)
1 - 10 2002-440 100 (4 x 25)
:
2
:
2002-1691 100 (4 x 25)
:
:
AWG 22 — 12
Appropriate marker systems:
100 (4 x 25)
Pack. unit
200 strips
N
N
25 A
25 A
2
2
0.25
400 V/6 kV/3
I
Terminal block width 5.2 mm / 0.205 in
L 10 — 12 mm / 0.43 in
4-conductor fuse terminal blocks
gray
End and intermediate plate, 1 mm/0.039 in thick
Protective warning marker, with high voltage symbol, black,
Staggered jumpers, light gray, insulated, I
Test plug adapter, for test plug Ø 4 mm/0.157 in
Testing tap, for max. 2.5 mm
Two-way marking adapter,
Test plug, with cable 500mm/1’7.7’’, Ø 2 mm/0.079 in
<______________ _ 87,5 mm /3.45 in _ ______________>
N
10 A
- Block arrangement: 5 A
Please note touchproof protection from 42 V
- Individual arrangement: 10 A
— 2.5 (4) mm
WMB/Marker Strips/WMB Inline
Item no.
2002-1881
orange 2002-1892 100 (4 x 25)
gray
for 5 terminal blocks
yellow 2002-115 100 (4 x 25)
12-way 2002-482 50 (2 x 25)
pivotable
red
2-way 2002-472 100 (4 x 25)
3-way 2002-473 100 (4 x 25)
4-way 2002-474 100 (4 x 25)
5-way 2002-475 50 (2 x 25)
:
2
2
/AWG 14
2002-1891 100 (4 x 25)
2009-174 100 (4 x 25)
2009-182 100 (4 x 25)
2002-121 50 (2 x 25)
210-136 50 (5 x 10)
:
AWG 22 — 12
N
25 A
Pack. unit
(see Full Line Catalog W4, Vol. 1, Sec. 14)
can be pushed in directly: 0.75 mm
The rated currents of the fuse cartridges are
defined differently in international standards.
Due to the different current rating definitions,
the recommended current-carrying permanent
capacity of the fuses is max. 80% of their rated
current according to DIN 72581 part 3 (for an
ambient operating temperature of 23°C).
Selecting the correct fuse cartrigde is important
for product safety within applications as well as
the service life/operational reliability of the fuse
cartrigdes. Fuse cartrigdes can operate perfectly
as protection (break-off point) if they are properly
selected and are used in accordance with
the manufacturers specifications.
In general it is necessary to test fuse cartridges
under normal conditions and operational failures
within your application.
With regard to the product safety, it is in
general necessary to test the fuse in the
appliance under normal conditions and
operational failures.
can be connected: 0.25 mm
0,75 mm
12 mm/0.472 in"
2
– 2,5 mm
2
— 4 mm
2
2
— 4 mm
"insulated ferrule,
2
"s+f-st";
2
"s" and
<_
_>
1
29

Related parts for 2002-0992

2002-0992 Summary of contents

Page 1

... Fuse Terminal Blocks for Blade-Type Fuses acc. to DIN 72581-3f, ISO 8820-3, Series 2002 — 2.5 ( 0.25 AWG 22 — 12 ➊ 400 V/6 kV ➋ N Terminal block width 5 0.205 — 0.43 in <________ 66,5 mm /2.61 in ________> Item no. Pack. unit 2-conductor fuse terminal blocks 2002-1681 gray ➋ ...

Page 2

... Fuse Disconnect Terminal Blocks with Pivotable Fuse Holder, 2.5 (4) mm /AWG 12, for Miniature Metric Fuses mm, Series 2002 2 34 800 V = rated voltage ➊ rated surge voltage 3 = pollution degree (see also Full Line Catalog W4, Volume 1, Section 15) Nominal voltage and current are given ➋ ...

Page 3

... Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2002-115 100 (4 x 25) must be singularized Push-in type jumper bars, light gray, insulated 2-way 2004-402 200 (8 x 25) ...

Page 4

... Electrical ratings are given by the fuse or nomi- nal voltage of the indicator lamp respectively. The use of pluggable fuse holders with rail mounted Pack. unit terminal blocks for protection of control circuits offers many advantages to the user since ...

Related keywords