21 03 111 2405 HARTING, 21 03 111 2405 Datasheet

CONNECTOR, FEMALE, M12, 4 POLE

21 03 111 2405

Manufacturer Part Number
21 03 111 2405
Description
CONNECTOR, FEMALE, M12, 4 POLE
Manufacturer
HARTING
Series
HARAXr
Datasheet

Specifications of 21 03 111 2405

Gender
Receptacle
Connector Mounting
Cable Mount
Connector Shell Size
M12
No. Of Contacts
4
Contact Termination
Crimp
Svhc
No SVHC (15-Dec-2010)
Connector Type
Circular Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Technical characteristics
HARAX® M8-S/M12-S
HARAX® M12 angled
HARAX® M12-L
Rated voltage
Rated current
Conductor cross section
Diameter of individual strands
Conductor insulation material
Conductor diameter
Cable diameter
Temperature limits
Temperature during connection
Degree of protection
Reconnection with the
same cable cross section
Working voltage
Working current
Wire gauge
Diameter of individual strands
Conductor insulation material
Conductor diameter
Cable diameter
Temperature limits
Temperature during connection
Degree of protection
Reconnection with the
same cable cross section
Rated voltage
Specifications IEC 60
Approvals
Show navigation
Adapter M8/M12
http://www.harkis.harting.com/WebHelp/GBHanGeraete/WebHelp/HARAX/AdapterM8_M12.htm (1 of 7)14/02/2006 10:31:51
352-4
IEC 60
9475-2
32 V
4A
0,14 mm² - 0,34 mm²
AWG 26 - 22
> 0.1 mm
PVC / PP
M8-S: 1.0 mm - 1.6 mm
M12-S: 1.0 - 1.6 mm
M8-S: 3.2 - 5.4 mm
M12-S: 4 mm - 5.1 mm
- 25 °C ... + 85 °C
- 5 °C ... + 50 °C
IP 67
10 times
32 V
4A
0,25 mm² - 0,5 mm²
AWG 24/7 - 22
> 0.1 mm
PVC
1.2 mm - 1.6 mm
4 mm - 5.1 mm
- 25 °C ... + 85 °C
- 5 °C ... + 50 °C
IP 67
10 times
50 V
HARAX® circular connector

Related parts for 21 03 111 2405

21 03 111 2405 Summary of contents

Page 1

... Conductor diameter Cable diameter Temperature limits Temperature during connection Degree of protection Reconnection with the same cable cross section HARAX® M12-L Rated voltage http://www.harkis.harting.com/WebHelp/GBHanGeraete/WebHelp/HARAX/AdapterM8_M12.htm (1 of 7)14/02/2006 10:31: 0,14 mm² - 0,34 mm² AWG > 0.1 mm PVC / PP M8-S: 1 1.6 mm M12-S: 1.0 - 1.6 mm M8-S: 3.2 - 5.4 mm M12- 5 ° ...

Page 2

... Conductor insulation material Conductor diameter Cable diameter Working temperature Temperature during connection Degree of protection Coding Number of terminations with same cable cross section Transmission characteristics acc. to http://www.harkis.harting.com/WebHelp/GBHanGeraete/WebHelp/HARAX/AdapterM8_M12.htm (2 of 7)14/02/2006 10:31: 0.34 mm² - 0.75 mm² AWG > 0.1 mm PVC 1 2 °C ... + 85 ° °C ... + 50 °C ...

Page 3

... The current carrying capacity is limited by maximum temperature of materials for insert and contacts including terminals. The current capacity- curve is valid for continuous, not interrupted current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature. Control and test procedures according to DIN IEC 60512-3. M8-S, 4 poles M12-S, 4 poles http://www.harkis.harting.com/WebHelp/GBHanGeraete/WebHelp/HARAX/AdapterM8_M12.htm (3 of 7)14/02/2006 10:31:51 ...

Page 4

... Adapter M8/M12 1 = wire gauge 0,25 mm² wire gauge 0,34 mm² M12, 4 poles, angled 1 = wire gauge 0,25 mm² wire gauge 0,5 mm² http://www.harkis.harting.com/WebHelp/GBHanGeraete/WebHelp/HARAX/AdapterM8_M12.htm (4 of 7)14/02/2006 10:31:51 ...

Page 5

... Adapter M8/M12 M12-L, 4 poles M12-L, shielded 1 = wire gauge 4 x 0,34 mm² wire gauge 4 x 0,75 mm² Assembly manual HARAX® http://www.harkis.harting.com/WebHelp/GBHanGeraete/WebHelp/HARAX/AdapterM8_M12.htm (5 of 7)14/02/2006 10:31:51 1. Strip cable 2. Assemble HARAX® elements 3. Cut off cable ends 4. Screw connector (1) Nut (2) Strain relief (3) Insert Screw the nut onto the insert until a stop is noticeable ...

Page 6

... Adapter M8/M12 Assembly instruction for shielded HARAX® M12-L http://www.harkis.harting.com/WebHelp/GBHanGeraete/WebHelp/HARAX/AdapterM8_M12.htm (6 of 7)14/02/2006 10:31:51 1. Strip cable 2. Assemble HARAX® elements, twist screening braid and push it into the sealing slot 3. Slide ring over the sealing cut off cable ends and the screening braid. ...

Page 7

... Adapter M8/M12 http://www.harkis.harting.com/WebHelp/GBHanGeraete/WebHelp/HARAX/AdapterM8_M12.htm (7 of 7)14/02/2006 10:31:51 ...

Related keywords