LM2596T-5.0 National Semiconductor, LM2596T-5.0 Datasheet - Page 13

DC/DC Converter IC

LM2596T-5.0

Manufacturer Part Number
LM2596T-5.0
Description
DC/DC Converter IC
Manufacturer
National Semiconductor
Datasheet

Specifications of LM2596T-5.0

Input Voltage
40V
Output Current
3A
Output Voltage
5V
No. Of Pins
5
Termination Type
Through Hole
Mounting Type
Through Hole
Voltage Regulator Type
Buck Switching
Output Current Max
3A
Dc
03+
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM2596T-5.0
Manufacturer:
NS
Quantity:
5 510
Part Number:
LM2596T-5.0
Manufacturer:
TI
Quantity:
8 946
Part Number:
LM2596T-5.0
Manufacturer:
ALTERA
0
Part Number:
LM2596T-5.0
Manufacturer:
TI/NS
Quantity:
12 000
Part Number:
LM2596T-5.0
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM2596T-5.0
Manufacturer:
NS
Quantity:
19 437
Part Number:
LM2596T-5.0
Manufacturer:
NSC
Quantity:
14 225
Company:
Part Number:
LM2596T-5.0
Quantity:
15 000
Part Number:
LM2596T-5.0/NOPB
Manufacturer:
NS44
Quantity:
315
Part Number:
LM2596T-5.0/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
LM2596T-5.0/NOPB
0
Company:
Part Number:
LM2596T-5.0/NOPB
Quantity:
1 080
Given:
V
V
I
F = Switching Frequency (Fixed at a nominal 150 kHz).
1. Programming Output Voltage (Selecting R
shown in Figure 1 )
Use the following formula to select the appropriate resistor
values.
Select a value for R
resistor values minimize noise pickup in the sensitive feed-
back pin. (For the lowest temperature coefficient and the best
stability with time, use 1% metal film resistors.)
2. Inductor Selection (L1)
A. Calculate the inductor Volt • microsecond constant E • T (V
where V
and V
B. Use the E • T value from the previous formula and match it
with the E • T number on the vertical axis of the Inductor Value
Selection Guide shown in Figure 7 .
C. on the horizontal axis, select the maximum load current.
D. Identify the inductance region intersected by the E • T value
and the Maximum Load Current value. Each region is identi-
fied by an inductance value and an inductor code (LXX).
E. Select an appropriate inductor from the four manufacturer’s
part numbers listed in Figure 8 .
• µs), from the following formula:
LM2596 Series Buck Regulator Design Procedure (Adjustable Output)
LOAD
OUT
IN
(max) = Maximum Input Voltage
PROCEDURE (Adjustable Output Voltage Version)
(max) = Maximum Load Current
D
= Regulated Output Voltage
= diode forward voltage drop = 0.5V
SAT
= internal switch saturation voltage = 1.16V
1
between 240
and 1.5 k . The lower
1
and R
2
, as
13
Given:
V
V
I
F = Switching Frequency (Fixed at a nominal 150 kHz).
1. Programming Output Voltage (Selecting R
shown in Figure 1 )
Select R
R
R
2. Inductor Selection (L1)
A. Calculate the inductor Volt • microsecond constant
(E • T),
B. E • T = 34.2 (V • µs)
C. I
D. From the inductor value selection guide shown in Figure 7 ,
the inductance region intersected by the 34 (V • µs) horizontal
line and the 3A vertical line is 47 µH, and the inductor code is
L39.
E. From the table in Figure 8 , locate line L39, and select an
inductor part number from the list of manufacturers part num-
bers.
LOAD
OUT
IN
2
2
(max) = 28V
= 1k (16.26 − 1) = 15.26k, closest 1% value is 15.4 k .
= 15.4 k .
LOAD
EXAMPLE (Adjustable Output Voltage Version)
(max) = 3A
= 20V
(max) = 3A
1
to be 1 k , 1%. Solve for R
2
.
1
www.national.com
and R
2
, as

Related parts for LM2596T-5.0