PIC18LF2410-I/ML Microchip Technology, PIC18LF2410-I/ML Datasheet - Page 186

IC,MICROCONTROLLER,8-BIT,PIC CPU,CMOS,LLCC,28PIN,PLASTIC

PIC18LF2410-I/ML

Manufacturer Part Number
PIC18LF2410-I/ML
Description
IC,MICROCONTROLLER,8-BIT,PIC CPU,CMOS,LLCC,28PIN,PLASTIC
Manufacturer
Microchip Technology
Series
PIC® 18Fr

Specifications of PIC18LF2410-I/ML

Rohs Compliant
YES
Core Processor
PIC
Core Size
8-Bit
Speed
40MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, HLVD, POR, PWM, WDT
Number Of I /o
25
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 5.5 V
Data Converters
A/D 10x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
28-VQFN Exposed Pad, 28-HVQFN, 28-SQFN, 28-DHVQFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18LF2410-I/ML
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
PIC18F2X1X/4X1X
16.4.17.1
During a Start condition, a bus collision occurs if:
a)
b)
During a Start condition, both the SDA and the SCL
pins are monitored.
If the SDA pin is already low, or the SCL pin is already
low, then all of the following occur:
• the Start condition is aborted,
• the BCLIF flag is set and
• the MSSP module is reset to its Idle state
The Start condition begins with the SDA and SCL pins
deasserted. When the SDA pin is sampled high, the
Baud Rate Generator is loaded from SSPADD<6:0>
and counts down to 0. If the SCL pin is sampled low
while SDA is high, a bus collision occurs because it is
assumed that another master is attempting to drive a
data ‘1’ during the Start condition.
FIGURE 16-26:
DS39636D-page 188
(Figure 16-26).
SDA or SCL are sampled low at the beginning of
the Start condition (Figure 16-26).
SCL is sampled low before SDA is asserted low
(Figure 16-27).
SDA
SCL
SEN
BCLIF
S
SSPIF
Bus Collision During a Start
Condition
BUS COLLISION DURING START CONDITION (SDA ONLY)
condition if SDA = 1, SCL = 1
Set SEN, enable Start
SDA sampled low before
Start condition. Set BCLIF.
S bit and SSPIF set because
SDA = 0, SCL = 1.
SDA goes low before the SEN bit is set.
Set BCLIF,
S bit and SSPIF set because
SDA = 0, SCL = 1.
SSPIF and BCLIF are
cleared in software
If the SDA pin is sampled low during this count, the
BRG is reset and the SDA line is asserted early
(Figure 16-28). If, however, a ‘1’ is sampled on the SDA
pin, the SDA pin is asserted low at the end of the BRG
count. The Baud Rate Generator is then reloaded and
counts down to 0; if the SCL pin is sampled as ‘0’
during this time, a bus collision does not occur. At the
end of the BRG count, the SCL pin is asserted low.
Note:
SEN cleared automatically because of bus collision.
SSP module reset into Idle state.
The reason that bus collision is not a factor
during a Start condition is that no two bus
masters can assert a Start condition at the
exact same time. Therefore, one master
will always assert SDA before the other.
This condition does not cause a bus
collision because the two masters must be
allowed to arbitrate the first address
following the Start condition. If the address
is the same, arbitration must be allowed to
continue into the data portion, Repeated
Start or Stop conditions.
SSPIF and BCLIF are
cleared in software
© 2009 Microchip Technology Inc.

Related parts for PIC18LF2410-I/ML