C30CNE20A0 EATON CUTLER HAMMER, C30CNE20A0 Datasheet - Page 40

Lighting Contactor

C30CNE20A0

Manufacturer Part Number
C30CNE20A0
Description
Lighting Contactor
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of C30CNE20A0

No. Of Poles
2
Contact Configuration
DPST-NC
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
120V
Contact Current Max
30A
Mounting Type
DIN Rail
External Height
187.6mm
Continuous Load Current
30A
Operating Voltage
600VAC
Switching Current Ac1
30A
Switching Current Ac3
30A
Load Current Inductive
30A
Contactor Direction
Reversing
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
37
37-40
Table 37-67. T — Timers, Time Delay Relays, Terminal Blocks, Terminal
Points, Ring Lug Connections (Continued)
Table 37-68. U — Undervoltage Relay, Time Delay Undervoltage Relay
Modification
Undervoltage
Relays
Time Delay
Undervoltage
Relays
Under- and
Overvoltage
Relay
Modification
IT./EM,
continued
Not available for IT. Starters.
Lighting Contactors
UL Rated AC Contactors
Modification Codes
Catalog
Number
Suffix
U1
U2
U4
U5
U7
Catalog
Number
Suffix
T60
T61
T62
T63A
T63D
T64
T70
T71
T72
T73
T74
T75
T76
T77
Description
Undervoltage Relay, Non-adjustable
Undervoltage Relay, Adjustable
Time Delay Undervoltage Relay,
Non-adjustable
Time Delay Undervoltage Relay, Adjustable
Under- and Overvoltage Relay
Description
Reset Only (DeviceNet)
STOP with Reset (DeviceNet)
FORWARD/REVERSE/STOP with Reset
(DeviceNet)
FORWARD/REVERSE/STOP with Reset 120V
AC (DeviceNet)
FORWARD/REVERSE/STOP with Reset 24V
DC (DeviceNet)
ON/OFF
Reset Only
START/STOP with Reset
HAND/OFF/AUTO – START with Reset
FORWARD/REVERSE/STOP with Reset
HAND/OFF/AUTO – FORWARD/REVERSE
with Reset
ON/OFF with Reset
FAST/SLOW/STOP with Reset
HAND/OFF/AUTO – FAST/SLOW with Reset
For more information visit: www.eaton.com
Table 37-69. V — Voltmeter, Varmeter, Vacuum Starter
Table 37-70. W — Wattmeter, Watt-Hour Meter, Wiremarkers, Wiring
Diagram
Modification
Voltmeters
Varmeter
Vacuum
Starter
Modification
Wattmeter
Watt-Hour
Meter
Wiremarkers
WYE-Delta hp
Windows in
Enclosure
Wiring
Diagram
Type 1/12 only.
Not available for XT Starters.
Type 1/12 only.
Not available for XT Starters.
Number
Suffix
V1
V2
V3
V4
V5
V6
V7
V8
V9
V10
V11
V12
V13
Number
Suffix
W1
W3
W5
W7
W8
W9
W10
W11
W12
Catalog
Catalog
Description
1 Panel Type Voltmeter Wired L1 – L2
Panel Type Voltmeter and Selector Switch
Wired to Read Three Line Voltages
Miniature Voltmeter Wired L1 – L2
Miniature Voltmeter and Selector Switch
Wired to Read Three Line Voltages
Switchboard Type Voltmeter Wired L1 – L2
Switchboard Type Voltmeter and Selector
Switch Wired to Read Three Line Voltage
3 Panel Type Voltmeters Wired in Each Phase
3 Miniature Voltmeters Wired in Each Phase
3 Switchboard Type Voltmeters Wired in
Each Phase
Voltmeter — Order by Description
Varmeter
Varmeter — Order by Description
Vacuum Starter — 1500V Rating
Description
Wattmeter
Watt-Hour Meter
Watt-Hour Meter with Demand Attachment
Wiremarkers
Wiremarkers — Order per Customer
Diagram or Specifications
Wiremarkers — Order by Description
See P03300001E
Enclosure Windows (MVX)
Reduced Copy of Custom Wiring
Diagram Laminated on Inside of Door
CA08102001E
June 2008

Related parts for C30CNE20A0