C30CNM20A02A0 EATON CUTLER HAMMER, C30CNM20A02A0 Datasheet

2-Wire Lighting Contactor

C30CNM20A02A0

Manufacturer Part Number
C30CNM20A02A0
Description
2-Wire Lighting Contactor
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of C30CNM20A02A0

No. Of Poles
2
Contact Configuration
DPST-NC
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
120V
Contact Current Max
30A
Mounting Type
DIN Rail
External Height
187.6mm
Continuous Load Current
30A
Operating Voltage
600VAC
Switching Current Ac1
30A
Switching Current Ac3
30A
Load Current Inductive
30A
Contactor Direction
Reversing
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
June 2008
CA08102001E
Contents
Description
Open Control
UL Rated AC — Enclosed
For more information visit: www.eaton.com
CN35 Electrically Held . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37-2
C30CN Mechanically Held . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37-8
A202 Magnetically Latched . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37-17
Product Family Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37-20
Non-combination C30CN Electrically and Mechanically Held . . . . . . . . . 37-23
Non-combination CN35 Electrically Held . . . . . . . . . . . . . . . . . . . . . . . . . . 37-24
Non-combination A202 Magnetically Latched. . . . . . . . . . . . . . . . . . . . . . 37-26
Combination Electrically Held and Magnetically Latched . . . . . . . . . . . . 37-28
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37-29
Modification Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37-33
Lighting Contactors
Mechanically Held, Magnetically Latched and
Electrically Held Lighting Contactors
Page
37-1
37

Related parts for C30CNM20A02A0

C30CNM20A02A0 Summary of contents

Page 1

... Non-combination C30CN Electrically and Mechanically Held . . . . . . . . . 37-23 Non-combination CN35 Electrically Held . . . . . . . . . . . . . . . . . . . . . . . . . . 37-24 Non-combination A202 Magnetically Latched 37-26 Combination Electrically Held and Magnetically Latched . . . . . . . . . . . . 37-28 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37-29 Modification Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37-33 Mechanically Held, Magnetically Latched and Electrically Held Lighting Contactors For more information visit: www.eaton.com 37-1 Page 37 ...

Page 2

... CN35TN (2-, 3-Pole) 100 – 300A Contactors Cat. No. C320AS1 This device mounts on top of any side mounted auxiliary contact on lighting contactors 100 – 300A. It connects across coil terminals on any 120V con- tactor magnet coil. Limits high voltage transients pro- duced in the circuit when power is removed from the coil. Table 37-2. Kits for 100 – ...

Page 3

... For Reference Only — not part of Catalog Number. See below left. Cannot be added to contactors or starters mounted in Box 1 (NEMA Type 1). Table 37-4. Auxiliary Contacts — 100 – 400A Contactors Circuit Contact 100A Contactors Configuration Catalog Code Number Base Auxiliary Contacts — ...

Page 4

... Available positions on contactors or starters other than what is factory installed. When a pneumatic timer is mounted on contactor, only side mounted auxiliary contact positions are available. The solid-state timer, when added, takes up side mounted auxiliary contact position. For 100 – 400A contactors, a base auxiliary contact must be added in position L1 before additional contacts can be mounted ...

Page 5

... Seconds 30 – 300 Seconds 5 – 30 Minutes Add operating voltage Suffix to Catalog Number 120V 240V 208V Rated .5 ampere pilot duty — not to be used on larger contactors. Terminal connections are quick connects only. Two per side. 20A, 30A Price 60A Price 100A U ...

Page 6

... Lighting Contactors 37-6 Open Control CN35 Electrically Held Dimensions Table 37-11. Approximate Dimensions and Shipping Weights Ampere Number Dimensions in Inches (mm) Rating of Wide Poles A Open Type 10 2 – 4 2.00 (50.8) 20 – – 3 2.00 (50.8) 20 – – 6 4.20 (106.7) 20 – 10.50 (266.7) 20 – ...

Page 7

... D 240/50 K For 10, 20 and 30A sizes only. For 10, 20 and 30A sizes only. Sizes 60 – 400A are 24V/60 Hz only. For DC Magnet Coils, see NEMA Contactors & Starters, Pages 33-88 – 33-89. For more information visit: www.eaton.com 37-7 Open Type Catalog Price Number U ...

Page 8

... Lighting Contactors 37-8 Open Control C30CN Mechanically Held Contents Description Open Control Product Description . . . . . . 37-8 Application Description . . . 37-8 Features . . . . . . . . . . . . . . . . 37-8 Operation . . . . . . . . . . . . . . 37-9 Instructional Leaflets . . . . . 37-9 Standards and Certifications . . . . . . . . . . 37-9 Technical Data and 37 Specifications . . . . . . . . . . 37-9 Components . . . . . . . . . . . . 37-10 Replacement Parts . . . . . . . 37-11 Wiring Diagrams ...

Page 9

... C30CN Lighting Contactor Series 50766 Coil Kit for C30CN Lighting Contactors 50767 Power Pole Kit for C30CN Lighting Contactors 50768 Control Module Kit for C30CN Lighting Contactors Standards and Certifications ■ UL Listed File E1491, UL Category Code/Guide NLDX/NLDX7 ■ cUL ■ CE CA08102001E ...

Page 10

... Single-Pole C320PRP1 Double-Pole C320PRP2 Mechanically Held Module Kits These kits are for converting electrically held contactors to mechanically held units. Kits include control module, latch, latch cover and auxiliary Electrically Held contacts plus installation instructions. Conversion kits are Base Contactor suitable for coil voltages of 277V and below. ...

Page 11

... Table 37-25. Auxiliary Contacts Auxiliary Block Catalog Number Single-Pole C320AMH1 Double-Pole C320AMH2 CA08102001E Lighting Contactors Open Control C30CN Mechanically Held Replacement Parts Magnet Coils for the Base Contactor Table 37-26. Magnetic Coils Coil Voltage 115 – 120V 60 Hz/110V 50 Hz 230 – 240V 60 Hz/220V 50 Hz 460 – ...

Page 12

... Lighting Contactors 37-12 Open Control C30CN Mechanically Held Wiring Diagrams C30CNE Electrically Held Line View Coil Optional Auxiliary Contacts Coil Voltage CONTROL Refer to View “B” for Control Connections Figure 37-5. C30CNE Wiring Diagrams Optional Pilot Devices for Electrically Held Contactor ...

Page 13

... Aux. Aux. Contacts Coil Contact O Voltage C 3-WIRE CONTROL Refer to View “C” for Control Connections Figure 37-6. C30CNM Wiring Diagrams CA08102001E Lighting Contactors Open Control C30CN Mechanically Held View B Optional Pilot Devices for 2-Wire Control SS Electronic-Module OFF ON P1 (AUTO) Control OFF ON ...

Page 14

... Mounting Holes #10 Screws .35 (9.0) 3.86 (98.0) Figure 37-7. Approximate Dimensions in Inches (mm) Catalog Number Selection Table 37-27. Type C30CN Lighting Contactors — Catalog Numbering System Product C30CN = Open 30A Lighting Contactor E = Electrically Held M = Mechanically Held Base Coil Voltage A = 115 – 120V 60 Hz/110V 230 – ...

Page 15

... Tables 37-29, 37-30 and 37-31 respectively. Table 37-28. 2-Wire Mechanically Held Lighting Contactors — Standard Assembled Forms Product Selection No Catalog Poles Number C30CNM02A02A0 1 1 C30CNM11A02A0 2 0 C30CNM20A02A0 C30CNM03A02A0 1 2 C30CNM12A02A0 2 1 C30CNM21A02A0 3 0 C30CNM30A02A0 ...

Page 16

... Mechanically Held Lighting Contactors — Standard Assembled Forms The Standard Assembled Forms in Table 37-32 are 3-wire open mechanically held 30 amp lighting contactors with 120V 60 Hz/ 110V 50 Hz base coil voltage, 120V control module voltage, and no additional auxiliary contacts. To change the base coil volt- age, auxiliary contact options or control module voltage, refer to Tables 37-33, 37-34 and 37-35 respectively. Table 37-32. 3-Wire Mechanically Held Lighting Contactors — ...

Page 17

... The Magnetically Latched Lighting Contactors are designed to withstand the large initial inrush currents of tungsten lamp loads without contact welding. ■ The A202 Contactors are fully rated devices that do not require de-rating similar to standard motor control contactors. Wiring Diagrams The standard wiring of an A202 con- ...

Page 18

... Lighting Contactors 37-18 Open Control A202 Magnetically Latched Renewal Parts Table 37-36. AC Coil Renewal Parts for A202 — Magnetically Latched Voltage Hz 2-, 3-, 4-Pole Part Number 30 Ampere 110/120 50/60 7874A93G01 208/240 7874A93G02 277 7874A93G03 440/480 7874A93G04 575 7874A93G05 60 Ampere 2-, 3-Pole 110/120 50/60 ...

Page 19

... Lighting contactors are not available with DC coils. Contactors rated 300A and 400A are mechanically latched. Underscore (_) indicates missing Code letter for Magnet Coil Selection — see Magnet Coil Selection Table. Table 37-41. Magnet Coil Selection Coil Voltage 120V ...

Page 20

... Accessories Page Auxiliary Contacts C30CN Electrically Held Contactors — The base C30CN product line can accept up to four auxiliary contacts (2NO/2NC), which are mounted on the top of the unit. The auxiliary contacts, rated A600, are also suitable for use on low-level circuits down to 12V, 5 mA. ...

Page 21

... Type 12 — Dust-Tight 9 = Type 4X — Watertight (316-Grade Stainless Steel) For normally closed poles see Page 37-36. C30CN available in 30A only. Enclosures Lighting contactors are available open or mounted in Type 1, 3R 7/9 enclosures. Type 1 is for indoor, general purpose for personal protection. Knock-outs are provided in the top and bottom for conduit entry ...

Page 22

... Lighting Contactors 37-22 UL Rated AC Contactors Product Family Overview Cover Control Table 37-44. Cover Mounted Pilot Devices Description ON/OFF Pushbuttons with Red RUN Pilot Light with Red RUN/GREEN off lights ON/OFF Pushbuttons with Red RUN Pilot Light with Red RUN/GREEN off lights ...

Page 23

... H 277/60 or 240/50 Note: To get the C30CN Lighting Contactor with normally closed power poles, see Page 37-36, section L, for Modification Codes. CA08102001E Lighting Contactors UL Rated AC Contactors Non-combination C30CN Electrically and Mechanically Held Type 4X Type 7/9 Price Catalog Price Catalog U ...

Page 24

... Lighting Contactors 37-24 UL Rated AC Contactors Non-combination CN35 Electrically Held Product Selection Table 37-47. Class ECL03 — Non-combination Electrically Held Lighting Contactor No. of Frame Type 1 Poles Size General Purpose Catalog Price Number U.S. $ Maximum Ampere Rating — ECL03A1_2A 3 ECL03A1_3A 4 ECL03A1_4A 5 ECL03A1_5A 6 ECL03A1_6A ...

Page 25

... Ampere ratings are based on a maximum load voltage of 480V for tungsten lamp applications and 600V for ballast or mercury vapor type applications. UL ballast and resistive ratings only. CA08102001E Lighting Contactors UL Rated AC Contactors Non-combination CN35 Electrically Held Type 4X Type 7/9 Watertight & Dust-Tight Hazardous Stainless Steel ...

Page 26

... Lighting Contactors 37-26 UL Rated AC Contactors Non-combination A202 Magnetically Latched Operation A permanent magnet is built into the contactor structure that will maintain the contactor in its energized state indefinitely without using control power. When energized current is applied to the latch coil, producing a Product Selection Table 37-48. Class ECL04 — ...

Page 27

... ECL04H2_6A Ampere ratings are based on a maximum load voltage of 480V for tungsten lamp applications and 600V for ballast or mercury vapor type applications. CA08102001E Lighting Contactors UL Rated AC Contactors Non-combination A202 Magnetically Latched Type 4X Type 7/9 Watertight & Dust-Tight Hazardous Stainless Steel Location ...

Page 28

... Lighting Contactors 37-28 UL Rated AC Contactors Combination Electrically Held and Magnetically Latched Product Selection Table 37-49. Class ECL12 & ECL13 — Combination Lighting Contactor — Fusible Disconnect Max. No. of Fuse Clips Type 1 Amp Poles Amps/ General Rating Volts Purpose Catalog Number Electrically Held — Class ECL12 ...

Page 29

... Remove wire “C” when it is supplied. Connect separate control lines to #1 terminal on the remote pilot device, and to the #96 terminal on the overload relay. Figure 37-11. Typical Wiring Diagram — C30CN CA08102001E Lighting Contactors UL Rated AC Contactors Wiring Diagrams Remote Control 2 Wire Control Not for use with auto reset OL relays. To Coil ...

Page 30

... K1 2 Red K1 3 Red *NOTE – 1 Contactor White B – 2 Contactors *C C – 3 Contactors Suitable for use on POWER TERMINATIONS a circuit capable of Use 60/75° C AI/Cu Conductors Only producing not more Contactor Wire Range than 5,000 (33 – 100A) Size or 10,000 (200A) RMS 30 Amp 14 – ...

Page 31

... Not for use with Stop auto reset OL relays. 1 2-Wire Control 3-Wire Control Remote Control Figure 37-13. Electrically Held Combination Contactors — CN35 CA08102001E Lighting Contactors UL Rated AC Contactors Wiring Diagrams Local Control (Flange-Mounting 2/13 If Used) See Figures 3/14 A,B, and F ...

Page 32

... Red 1 START/STOP Selector Switch Figure B 3 Black/White X1 Connect to Terminals ”3“ and ”L2“ Black/White Pilot Light (ON) Figure C Local Control Figure 37-14. Magnetically Latched Combination Contactors L2 L3 CPT Fusible Control Transformer (If Used) See Figure ”C“ Local Control + (Flange- Mounting If Used) – ...

Page 33

... Accelerating A46 Relay A47 Oversize enclosure will be provided for IT. Starters. Top mounted auxiliary contacts cannot be added to contactors in Box 1 (Type 1). Not available for IT. Starters. Available on XT Starters for 40A and greater only. Table 37-53. B — Breaker Modifications, Backspin Timer, Undervoltage Release, Bell Alarm, Bus Choke Modifi ...

Page 34

... Table 37-54. C — Control Power Transformer, IT. Power Supplies, Control Relays, Cover Control (not elsewhere defined), Current Transformers, Compelling Relay, Control Wiring, Control Circuit Breaker, Separate Control, Customer-Supplied Components, Custom for Advantage, Contactors, Counter, E-Stop Relay, DC/AC Interface, Separate Source Disconnect, Bypass Contactors (Continued) Modification Catalog Number Suffi ...

Page 35

... Green — OFF for each starter D27 Green — Push-to-Test OFF for ea. starter Not available for IT Starters. CA08102001E Lighting Contactors UL Rated AC Contactors Modification Codes Table 37-56. E — Enclosure Modifications, Elapsed Time Meter, Duplex Outlet, Enclosure for Starter, Enclosure Clear Cover, Enclosure Material Modification ...

Page 36

... Lighting Contactors 37-36 UL Rated AC Contactors Modification Codes Table 37-58. G — Ground Fault Relay, Grounding Modification Catalog Description Number Suffix Ground Fault G1 Ground Fault Relay (Wired) Relay G3 Ground Fault Relay (Unwired) Grounding G5 Special Grounding — Order by Description G6 Ground Fault Protection Omitted ...

Page 37

... P29 Pilot Light — Red STOP Not available for IT. Starters. CA08102001E Lighting Contactors UL Rated AC Contactors Modification Codes Table 37-63. P — Pilot Lights, Pushbuttons, Phase Relays, Potential Transformers, Power Factor Correction Capacitors, Program Timer, Percentage Timer, Photocell (Continued) Modification Catalog Number Suffi ...

Page 38

... Lighting Contactors 37-38 UL Rated AC Contactors Modification Codes Table 37-64. Q — IQ Products, DN50 Modification Catalog Description Number Suffix IQ Products Q1 IQ 500 Q3 IQ 1000 Q5 IQ 4000 Q8 With Wponi (Advantage) Q9 With WCTLponi (Advantage) IQ Data Q12 IQ Data Metering Module Metering Q14 IQ 220 with Cable ...

Page 39

... When using 3-position selector switch with magnetic lighting contactor, mod C20 must also be used (ECL04, ECL13, ECL15). Not available for IT. Starters. CA08102001E Lighting Contactors UL Rated AC Contactors Modification Codes Table 37-67. T — Timers, Time Delay Relays, Terminal Blocks, Terminal Points, Ring Lug Connections Modification ...

Page 40

... Lighting Contactors 37-40 UL Rated AC Contactors Modification Codes Table 37-67. T — Timers, Time Delay Relays, Terminal Blocks, Terminal Points, Ring Lug Connections (Continued) Modification Catalog Description Number Suffix IT./EM, T60 Reset Only (DeviceNet) continued T61 STOP with Reset (DeviceNet) ...