G6B-4BND DC24 Omron, G6B-4BND DC24 Datasheet - Page 2

POWER RELAY, 4PST-NO, 24VDC, 5A DIN RAIL

G6B-4BND DC24

Manufacturer Part Number
G6B-4BND DC24
Description
POWER RELAY, 4PST-NO, 24VDC, 5A DIN RAIL
Manufacturer
Omron
Datasheet

Specifications of G6B-4BND DC24

Relay Type
General Purpose
Coil Voltage Vdc Nom
24V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
2880ohm
Contact Configuration
4PST-NO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications
■ Ratings
Coil Ratings (per G6B Relay)
Note: 1. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±10%.
Contact Ratings
Note: This value fulfills the P reference value of opening/closing at a rate of 120 times per min (ambient operating environment and determination
■ Characteristics
Note: 1. The above values are initial values.
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Classification
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Error rate (reference value) (see note) 10 mA at 5 VDC
Contact resistance (see note 2)
Operate time
Release time
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
2. Operating characteristics were measured at a coil temperature of 23°C.
3. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is
4. Diodes to absorb coil surge are equivalent to S5688J (reverse voltage resistance: 600 V; forward current: 1 A).
5. The values in parentheses are for the G6B-4FB1ND and G6B-4FPND.
6. The rated current includes the LED current.
criteria according to JIS C5442).
2. Measurement condition: 1 A at 5 VDC
no continuous allowance.
G6B-4BND (standard), G6B-47BND (long-life)
Resistive load
(cosφ = 1)
5 A at 250 VAC,
5 A at 30 VDC
5 A
380 VAC, 125 VDC
5 A
1,250 VA, 150 W
5 VDC
35.5 mA (43.4)
125 Ω
80% max. of rated voltage
10% min. of rated voltage
130% of rated voltage
Approx. 200 mW
100 mΩ max.
10 ms max. (approx. 3 ms)
15 ms max. (approx. 4 ms)
1,000 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between coils of different polarity
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 100 m/s
Mechanical: 50,000,000 operations min. (at 18,000 operations/hr)
Electrical:
Operating: –25°C to 55°C (with no icing or condensation)
Storage:
Operating: 35% to 85%
Approx. 75 g
–25°C to 55°C (with no icing or condensation)
100,000 operations min. (at 1,800 operations/hr, rated load)
500,000 operations min. for long-life at 2 A
100,000 operations min for long-life at 5 A
2
(approx. 10G)
2
(approx. 100G)
Inductive load
(cosφ = 0.4, L/R = 7 ms)
2 A at 250 VAC,
2 A at 30 VDC
500 VA, 60 W
12 VDC
19.1 mA
720 Ω
G6B-48BND (high-reliability)
Resistive load
(cosφ = 1)
2 A at 250 VAC,
2 A at 30 VDC
2 A
2 A
500 VA, 60 W
1 mA at 1 VDC
24 VDC
10.7 mA (10.3)
2,880 Ω
Inductive load
(cosφ = 0.4, L/R = 7 ms)
0.5 A at 250 VAC,
0.5 A at 30 VDC
125 VA, 15 W
G6B-4@@ND
2

Related parts for G6B-4BND DC24