RPF2BP7 SQUARE D, RPF2BP7 Datasheet - Page 35

POWER RELAY, DPDT, 230VAC, 30A, DIN RAIL

RPF2BP7

Manufacturer Part Number
RPF2BP7
Description
POWER RELAY, DPDT, 230VAC, 30A, DIN RAIL
Manufacturer
SQUARE D
Datasheet

Specifications of RPF2BP7

Relay Type
Power
Coil Voltage Vac Nom
230V
Contact Current Max
30A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
28V
Coil Resistance
6500ohm
Contact Configuration
DPDT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
www.schneider-electric.us
Table 23.170:
© 2009 Schneider Electric
All Rights Reserved
Class/Type
8430 MPS
8430 MPD
Phase
Loss
Yes
Yes
Control and Measurement
Relays
Unbalance
Protects Against
Square D
8430 phase failure relays offer the reliability and accuracy of solid state circuitry with the isolation of hard output
contacts.
Phase Abnormality Definitions
Phase Loss: This condition occurs when one line of a 3 phase system is completely lost.
Phase Unbalance: This condition occurs when the voltage in one line of a 3 phase system drops below the voltage in
the remaining two lines.
Phase Reversal: This condition occurs when two of three lines in a 3 phase system are switched. This incorrect
connection will cause a motor to rotate in the reverse direction.
Undervoltage: This condition occurs when the voltage in all three lines of a 3 phase system drop simultaneously.
Phase
Note: For 8430 MPS Sockets, see page 23-13.
Table 23.171: Operating Data
Table 23.172: Contact Ratings
Table 23.173: How to Order
For Mounting Track for the 8430 MPS relays . . . . . . . . . . . . . . . . .page 23-23
Power Consumption
Ambient Temperature
Devices are auto reset, so 3 wire control should be used to accomplish safe operation of equipment.
Type
To Order Specify:
Yes
Yes
MPD
MPS
Class Number
Type Number
Voltage Code
3.39
MPS:
MPD:
86
3.35
85
Contacts
Reversal
Phase
SPDT
DPDT
Yes
Yes
2.75
70
®
3.98
101
Type MPS 240 V
Phase Failure Relays
Voltage
Under
Maximum
Control
Circuit
Voltage
Yes
Yes
File E78403 CCN NLDX provided the proper socket is used.
8430MPSV24 - 8501 NR51 or NR52 socket (see page 23-13).
8430MPSV29 - 8501 NR82 socket (see page 23-13).
File E78403 CCN NLDX
120
240
120
240
480
600
2.36
Class
Phase Failure and Undervoltage Relay
The Type MPS is a socket mounted, voltage sensing phase failure relay. The
undervoltage setting is adjustable from 75% to 100% of normal voltage. The
relay is UL Listed with the appropriate socket (see socket selection on
page 23-13). The 240 V rated, SPDT output contacts change state upon
phase failure, undervoltage, phase reversal or phase unbalance of 10% or
greater. Response time delay is 3 seconds.
Phase Failure and Undervoltage Relay
The Type MPD offers the same protection as the Type MPS plus the
following features: DPDT 600 V rated output contacts, locking potentiometer
undervoltage adjustment and an LED indicating “relay energized.” Can be
mounted directly to a panel or to 8501 XM track (see page 23-23).
60
8430
Type MPS
Type MPD
Catalog Number
Make
VA
1800
1800
3400
3600
3600
3600
Inductive
1.73
44
Type
MPS
Break
VA
180
180
340
360
360
360
CP1
Voltage
Code
Make & Break
Amperes
V24
Discount
Schedule
AC Ratings
3.78
104
4.09
96
Description
2.5
2.5
5
5
5
5
Resistive
3.50
89
4.37
111
+23
Type MPS 480 V
-5
Thermal
Continuous
Current
o
o
5.5 VA
C to 50
F to 122
7 VA
5
5
5
5
5
5
o
C
o
2.36
F
60
NLDX2 without using
1.73
44
File E78403 CCN
the sockets listed.
Class 8430 / Refer to Catalog 8430CT9701
Arrangement
Contact
SPDT
DPDT
4.57
116
Nominal
Voltage
240–60
480–60
120–60
240–60
480–60
600–60
File 060905 -174
Class 3211-03
Type MPD
Prov. for
(2) #8 Mtg. Screws
3.50
89
0.20
5
MPSV24
MPSV29
MPDV20
MPDV24
MPDV29
MPDV32
3.11
79
Type
Type MP
1.10
28
2.20
56
$ Price
329.00
732.00
23-35