G6EK-134P-US 5DC Omron, G6EK-134P-US 5DC Datasheet

RELAY, PCB, SPCO, 5VDC, LATCHING

G6EK-134P-US 5DC

Manufacturer Part Number
G6EK-134P-US 5DC
Description
RELAY, PCB, SPCO, 5VDC, LATCHING
Manufacturer
Omron
Datasheet

Specifications of G6EK-134P-US 5DC

Contact Current Max
3A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
5V
Coil Resistance
125ohm
Coil Power
RoHS Compliant
Coil Type
DC Coil, Sensitive
Coil Current
40mA
Contact Configuration
SPDT
Rohs Compliant
Yes
Subminiature, Sensitive SPDT Signal
Switching Relay
Ordering Information
Model Number Legend
2. Contact Form
Note: When ordering, add the rated coil voltage to the model number.
1. Relay Function
SPDT
G6E
RoHS Compliant
High sensitivity: 98-mW pickup coil power.
Impulse withstand voltage meets FCC Part 68
requirements.
Fully sealed construction.
Unique moving loop armature reduces relay size,
magnetic interference, and contact bounce time.
Single- and double-winding latching types also
available.
1:
None: Single-side stable
U:
K:
PCB Relay
Example: G6E-134P-US 12 VDC
Contact form
1
Double-winding latching
Single-winding latching
SPDT
-
2 3 4 5 6
Bifurcated
crossbar
Refer to pages 16 to 17 for details.
Straight terminal
Self-clinching termi-
nal
-
Terminal
7
-
4. Enclosure Ratings
5. Terminals
6. Special Function
3. Contact Type
Rated coil voltage
8 9
3: Bifurcated crossbar
9: Bifurcated crossbar
4: Fully sealed
P: Straight PCB
C: Curved tail
L: Low sensitivity coil (400 mW)
AgNi (Au-Alloy) contact
Ag (Au-Alloy) contact
VDC
G6E-134P-US
G6E-134C-US
Single-side stable
7. Approved Standards
8. Special Function
9. Rated Coil Voltage
G6EU-134P-US
G6EU-134C-US
Single-winding latching Double-winding latching
US: UL, CSA certified
U:
3, 5, 6, 9, 12, 24, 48 VDC
For ultrasonically cleanable
G6EK-134P-US
G6EK-134C-US
G6E
R
C
57

Related parts for G6EK-134P-US 5DC

G6EK-134P-US 5DC Summary of contents

Page 1

... Special Function 9: Bifurcated crossbar AgNi (Au-Alloy) contact 9. Rated Coil Voltage 4. Enclosure Ratings 4: Fully sealed 5. Terminals P: Straight PCB C: Curved tail 6. Special Function L: Low sensitivity coil (400 mW) G6E Single-winding latching Double-winding latching G6EU-134P-US G6EK-134P-US G6EU-134C-US G6EK-134C-US US: UL, CSA certified U: For ultrasonically cleanable 12, 24, 48 VDC ...

Page 2

G6E Specifications Coil Ratings ■ Single-side Stable, Bifurcated Crossbar Contact Type Rated voltage 3 VDC Rated current 66 Ω Coil resistance Coil inductance Armature OFF 0.08 (H) (ref. value) Armature ON 0.06 Must operate voltage 70% max. of ...

Page 3

G6E Characteristics ■ Ω max. Contact resistance (See note 1.) Operate (set) time (See note 2 max. (approx. 2.9 ms; 48 VDC type: approx. 2.4 ms) Release (reset) time (See note 2 max. (approx. ...

Page 4

... Switching current (A) Note: The maximum coil voltage refers to the G6E Ambient Temperature vs. Maximum Coil Voltage G6E-134P-US G6EK-134P-US G6EU-134P-US G6E-134P-US Only at 48VDC Ambient temperature (°) maxi-mum value in a varying range of operating power voltage, not a continuous voltage. ...

Page 5

G6E Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Orientation marks are indicated as follows: G6E-134P-US G6E-194P-US 16 max. (15.9) * 0.6 1.6 5.08 G6E-134C-US G6E-194C-US 16 max. (15.9) * 3.16 2.86 0.6 1.6 5.08 G6EU-134P-US ...

Page 6

... G6E G6EK-134P-US G6EK-194P-US 16 max. (15.9) * 0.6 1.6 5.08 G6EK-134C-US G6EK-194C-US 16 max. (15.9) * 2.86 3.16 0.6 1.6 5.08 Precautions Refer to page 25 for information on general precautions. Be sure to read these precautions before using the Relay. Precautions for Correct Use ■ Long-term Continuously ON Contacts Using the Relay in a circuit where the Relay will be ON continu- ...