G6JU-2FL-Y-DC12 Omron, G6JU-2FL-Y-DC12 Datasheet

SIGNAL RELAY, DPDT, 12VDC, 1A, SMD

G6JU-2FL-Y-DC12

Manufacturer Part Number
G6JU-2FL-Y-DC12
Description
SIGNAL RELAY, DPDT, 12VDC, 1A, SMD
Manufacturer
Omron
Series
G6JYr
Datasheets

Specifications of G6JU-2FL-Y-DC12

Contact Configuration
DPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
12V
Coil Resistance
1329.2ohm
Coil Type
DC
Coil Current
9mA
Contact Form
2 Form C
Coil Voltage
12 VDC
Power Consumption
100 mW
Termination Style
Solder Pad
Maximum Switching Current
1 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Ultra-compact and Slim DPDT Relay
• Dimensions of 9H x 5.7W x 10.6L mm provide a mounting
• Dielectric strength of 1,500 VAC and an impulse withstand
• Conforms to FCC Part 68 requirments (1,500 V,10 x 160 μs).
• Single-winding latching models to save energy.
• UL recognized / CSA certified.
• RoHS Compliant.
Ordering Information
.
Model Number Legend:
Application Examples
Communications equipment, measurement devices, computer peripheral devices, office automation equipment, and audio-visual products.
Note 1: When ordering, add the rated coil voltage to the model number.
Note 2: When ordering tape packing, add “-TR” to the model number.
Terminal
PCB through-hole
SMT Gull-wing
SMT Shortened leads
1. Relay Function
2. Contact Form
3. Terminal Shape
area reduction of approx. 56% when compared with the
OMRON G6S.
voltage of 2,500 V for 2 x 10 μs
(conforms to Telcordia specifications (formerly Bellcore)).
G6J
Surface-mounting Relay
G6J-Y
None: Non-latching, standard
U:
P:
FL: SMT Gull-wing
FS: SMT shortened leads
2:
1
PCB through-hole terminals
Example: G6J-2P-Y DC12
Example: G6J-2P-Y-TR DC12
“-TR” is not part of the relay model number. Therefore it is not marked on the relay case.
Single-winding latching
-
DPDT
2 3
- Y -
Item
Contact form
DPDT
4
DC
Rated coil voltage
5
Rated coil voltage
Non-latching
G6J-2P-Y
G6J-2FL-Y
G6J-2FS-Y
4. Packaging
9. Rated Coil Voltage
TR:
None: Tube packaging
3, 4.5, 5, 12, 24
Surface-mounting Relay
Tape and reel packaging
Model
Single coil latching
G6JU-2P-Y
G6JU-2FL-Y
G6JU-2FS-Y
G6J-Y
57

Related parts for G6JU-2FL-Y-DC12

G6JU-2FL-Y-DC12 Summary of contents

Page 1

... Application Examples Communications equipment, measurement devices, computer peripheral devices, office automation equipment, and audio-visual products. Model Non-latching Single coil latching G6J-2P-Y G6JU-2P-Y G6J-2FL-Y G6JU-2FL-Y G6J-2FS-Y G6JU-2FS-Y 4. Packaging None: Tube packaging TR: Tape and reel packaging 9. Rated Coil Voltage 3, 4.5, 5, 12, 24 Surface-mounting Relay G6J-Y 57 ...

Page 2

... Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. G6JU-Y Single coil, Latching (G6JU-2P-Y, G6JU-2FL-Y, G6JU-2FS-Y) Rated voltage Rated current ...

Page 3

... The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those for checking the dielectric strength. 4. The above values are initial values. Standard non-latching relays G6J-2P-Y, G6J-2FS-Y, G6J-2FL max. (approx. 0.9 ms min. (at 100% rated coil voltage) 2 (approx. 100G) 2 (approx. 75G) Surface-mounting Relay Single coil latching relays G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y G6J-Y 59 ...

Page 4

... Unit: m Sample: G6J-2P-Y Z' Number of Relays Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. Contact Reliability Test (See note.) 1,000 Sample: G6J-2P-Y NO contact Number of Relays: 10 Test conditions: 10 μA resistive load ...

Page 5

... Frequency (MHz) Surface-mounting Relay Average value + +20 +10 0 −10 −20 Sample: G6J-2P-Y Must Operate voltage Number of Relays: 5 Must Release voltage −30 −1,200 −800 −400 0 400 800 1,200 External magnetic field (A/m) Average value 0 3.5 3 2.5 2-pole return loss 2 1-pole return loss 1 ...

Page 6

... Must Operate bounce time Must Operate bounce time 35 Must Release bounce time 35 Must Release bounce time Sample: G6J-2P-Y Sample: G6J-2P-Y Number of Relays: 30 Number of Relays 0.5 1 1 0.5 1 1.5 2 2.5 3 Time (ms) Time (ms) G6J-Y Vibration Resistance 5.0 4.0 3.0 2.0 1.0 Must Operate voltage 0 ...

Page 7

... Orientation mark holes 3.2 − (1.25) G6JU-2P-Y Orientation mark − − Terminal Arrangement/ Internal Connections (Top View) G6J-2FS-Y Orientation mark 2. − 4. G6JU-2FS-Y Orientation mark − − Terminal Arrangement/ Internal Connections (Top View) G6J-2FL-Y Orientation mark 3 − 5 G6JU-2FL-Y Orientation mark − − ...

Page 8

... Surface-mounting Relay Carrier Tape Dimensions G6J-2FS-Y, G6JU-2FS-Y 16± 0.1 2± 4± 0.1 0.1 Stopper (green) A 6.2± 8.3± 0.1 5° max. G6J-2FL-Y, G6JU-2FL-Y 16± 0.1 2± 4± 0.1 A 7.9± 0.1 5° max. Orientation mark Pulling direction dia. 13± 0.2 ± ...

Page 9

... Contact form Coil rating DPDT G6J-2P-Y, 2FS-Y, 2FL- VDC G6JU-2P-Y, 2FS-Y, 2FL- VDC • The thickness of cream solder to be applied should be between 150 and 200 μm on OMRON's recommended PCB pattern. • In order to perform correct soldering recommended that the correct soldering conditions be maintained as shown below on the left-hand side ...

Page 10

... Mounting Latching Relays The Latching Relays are reset before shipping. If excessive vibration or shock is imposed, however, the Latching Relays may be set acci- dentally. Be sure to apply a reset signal before use. Make sure that the vibration or shock that is generated by other devices on the same panel does not exceed the rated value of the Latching Relays ...

Page 11

... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...

Page 12

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...