H3CR-A8E 100-240VAC/100-125VD Omron, H3CR-A8E 100-240VAC/100-125VD Datasheet - Page 42

Solid State Timer

H3CR-A8E 100-240VAC/100-125VD

Manufacturer Part Number
H3CR-A8E 100-240VAC/100-125VD
Description
Solid State Timer
Manufacturer
Omron

Specifications of H3CR-A8E 100-240VAC/100-125VD

Contact Configuration
SPDT
Nom Input Voltage
240VAC
Timing Adjustment
Knob
Relay Mounting
DIN Rail
H3CR
Operation
Note: The undermentioned is common for all H3CR models.
Setting of Selectors
The selectors can be turned clockwise and counterclockwise to se-
lect the desired time unit, time range, or operating mode.
Each selector has a snap mechanism that secures the selector at a
given position. Set the selector at a position at which it is secured.
Do not set it midway between two securing positions or a malfunc-
tion could result from improper setting.
Selection of Operating Mode
Turn the operating mode selector with a screwdriver until the de-
sired operating mode (H3CR-A/AP/AS: A, B, B2, C, D, or E,
H3CR-A8/A8S/A8E: A, B2, E or J, H3CR-A-300: G or J) appears in
the display window located above the selector.
Selection of Time Unit and Time Range
The desired time unit (sec, min, hrs, or 10h) is displayed in the win-
dow below the time setting knob by turning the time unit selector lo-
cated at the lower right corner of the front panel. A time range (1.2, 3,
12, or 30/2.4, 6, 24, or 60 for H3CR-Aj-301) is selected with the
time range selector at the lower left corner of the front panel, and the
selected time range appears (in the window at the lower right part)
within the plastic frame of the time setting knob.
44
Basic Setting
H3CR-A Multifunctional Timer
H3CR-A Multifunctional Timer
Operating mode
selector
Time setting
knob
Time range
selector
(i.e., H3CR-A)
Time unit display window
Time unit selector
Operating mode
display window
Groove for
screwdriver
Scale range
display window
A time range (0 to 1.2, 0 to 3, 0 to 12, or 0 to 30) is selected for ON-
and OFF-time using the time range selector at the lower left corner
of the front panel, and the selected time range appears within the
plastic frame of the time setting knob (= scale range display win-
dows).
For ON-time, the desired time unit (sec, 10 s, min, and hrs, or 10 s,
10 min, hrs, and 10 h) is indicated in the ON-time unit display win-
dow at the lower right corner of the front panel and can be changed
by turning the ON-time unit selector located below the ON-time unit
display window.
For OFF-time, the desired time unit (sec, 10 s, min, and hrs, or 10 s,
10 min, hrs, and 10 h) is indicated in the OFF-time unit display win-
dow at the upper right corner of the front panel and can be changed
by turning the OFF-time unit selector located below the OFF-time
unit display window.
H3CR-F Twin Timers
Time range
selector
ON-time unit
selector
OFF-time unit
selector
H3CR

Related parts for H3CR-A8E 100-240VAC/100-125VD