H3DS-ML Omron, H3DS-ML Datasheet

TIMER, 8 MODE

H3DS-ML

Manufacturer Part Number
H3DS-ML
Description
TIMER, 8 MODE
Manufacturer
Omron
Datasheet

Specifications of H3DS-ML

Contact Configuration
SPDT
Nom Input Voltage
230V
Delay Time Range
0.1s To 120h
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Coil Voltage Vac Nom
230V
Coil Voltage Vdc Nom
24V
Contact Current Ac Max
5A
Timing Adjustment
Screwdriver Slot
DIN Track Mounted, Standard 17.5-mm Width Timer Range
Ordering Information
Note: The operating modes are as follows:
4
24 to 230 VAC (50/60Hz)/
24 to 48 VDC
A wide AC/DC power supply range (24 to 230 VAC/
24 to 48 VDC) reduces the number of timer models
kept in stock.
Eight operating modes (H3DS-M) and four
operating modes (H3DS-S) cover a wide range of
applications.
A wide time setting range of 0.10 s to 120 h.
Two LEDs indicate power and relay status
respectively.
Smart Dial/Selector-locking Mechanism: Prevents
the dials and selectors on the Timer’s front panel
from being inadvertently operated or being
operated without authorization. The lock can only
be unlocked and locked with an optional pen-type
Lock Key.
Screwless spring terminal type available.
Sticker provided for easy timer identification and
management.
Terminal clamp left open when delivered (screw
terminal type).
Finger
VDE0106/P100.
Enables easy sequence checks through instanta-
neous outputs for a zero set value at any time
range.
Conforms
(VDE0110) 4 kV/2.
Conforms to EMC standards (EN50081-1 and
EN50082-2).
Solid-state Multi-functional Timer
Supply voltage
Supp y o age
protection
A: ON-delay
B: Flicker OFF start
B2: Flicker ON start
C: Signal ON/OFF-delay
D: SIgnal OFF-delay
E: Interval
G: Signal ON/OFF-delay
J: One shot
to
EN61812-1
terminal
Contact output:
SPDT
(time-limit output
SPDT)
Control output
Co
)
o ou pu
and
block
IEC60664-1
to
Voltage input
No-input available
meet
Input type
pu
ype
Eight multi-modes: A,
B, B2, C, D, E, G, J
Four multi-modes: A,
B2, E, J
Single mode: A
Operating mode
Ope a
(
(see note)
g
t )
ode
H3DS-ML
H3DS-SL
H3DS-AL
terminal type
Screw
H3DS
R C
Model
H3DS-MLC
H3DS-SLC
H3DS-ALC
terminal type
Screwless
spring

Related parts for H3DS-ML

H3DS-ML Summary of contents

Page 1

... J: One shot 4 block to meet and IEC60664-1 Input type pu ype Voltage input Eight multi-modes B2 No-input available Four multi-modes Single mode: A H3DS R C Model Ope a Operating mode g ode (see note Screw Screwless terminal type terminal type H3DS-ML H3DS-MLC H3DS-SL H3DS-SLC H3DS-AL H3DS-ALC spring ...

Page 2

... Accessories (Order Separately) Lock Key Mounting Track End Plate Spacer Specifications General Item H3DS-MLj Operating mode A: ON-delay (Signal or Power) B: Flicker OFF start (Signal or Power) B2: Flicker ON start (Signal or Power) C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval (Signal or Power) G: Signal ON/OFF-delay J: One-shot (Signal or Power) Input type ...

Page 3

... Timer with a solid-state output such as a sensor. 3. The power consumption is for mode A after the Timer counts the time-up time and for the AC input at 50 Hz. The power consumption of the H3DS-ML includes the input circuit with the B1 and A1 terminals short-circuited. 6 ...

Page 4

... ENV50204: Immunity Conducted Disturbance: ENV50141: Immunity Burst: EN61000-4-4:2 kV power line (level 3) Light gray (5Y7/1) IP30 (Terminal block: IP20) 100 g H3DS 8 kV air discharge (level 3) 10 V/m (80 MHz to 1 GHz) (level 3) 10 V/m (900 5 MHz) (level (0. MHz) (level I/O signal line (level 4) 7 ...

Page 5

... Operating mode display window and selector (select the mode from and J for the H3DS-ML, from A, B2, E, and J for the H3DS-SL) H3DS-ALj Output indicator (orange) (Lit while Timer output is ON.) Set time window ...

Page 6

... J. Turn the operating mode selector with a screwdriver until the desired operating mode appears in the operating mode display win- dow. H3DS-ML (8 modes B2 (In order of appearance) H3DS-SL (4 modes B2 (In order of appearance) Note: Letters that appear more than once indicate exactly the same operating mode. ...

Page 7

... Output relay and 16 Output relay: NO (output indicator) 15 and 18 Power indicator Note: The start input of the H3DS-MLj model is activated by applying a voltage to B1 and A2 terminals. The voltage can be applied by turning on the contact between B1 and A1 (Refer to T erminal Arrangement ). 10 Timing chart t t– t– ...

Page 8

... Output relay 0.6 s (output indicator) (fixed) 15 and 18 Power indicator Note: The start input of the H3DS-MLj model is activated by applying a voltage to B1 and A2 terminals. The voltage can be applied by turning on the contact between B1 and A1 (Refer to T erminal Arrangement ). Timing chart t–a t–a t t–a ...

Page 9

... H3DS Dimensions Note: All units are in millimeters unless otherwise indicated. H3DS-MLj/-SLj/-ALj Installation Terminal Arrangement H3DS-MLj (see note 1) Note supply voltage does not require the designation of polarity. 2. The contact symbol for the H3DS is indicated with contact for conventional timers. 12 Surface color: Light gray 5Y7/1 (OMRON) ...

Page 10

... H3DS Input Connections The inputs of the H3DS-MLj are voltage (voltage imposition or open) inputs. No-contact Input (Connection to PNP output sensor.) Sensor Timer (+) Start 24 VDC (– Operates with PNP transistor ON Voltage Input Signal Levels 1. Transistor ON Residual voltage max. (Voltage between terminals B No-contact input the rated “ ...

Page 11

... Note: The values shown in parentheses are for the PFP-50N. End Plate PFP pan head screw 14 PFP-100N2 7.3 0.15 4.5 27 0. (5) (see note) Spacer PFP-S 10 6.2 1.8 1 35.5 35.3 1.8 1.3 4.8 H3DS 0 1,000 34.8 44.3 16.5 29.2 1.5 ...

Page 12

... Timer may not be reset or a timer error could result. For the power supply of an input device of the H3DS-MLj, use an isolating transformer, of which the primary and secondary windings are mutually isolated and the secondary winding is not grounded. ...

Page 13

... H3DS-MLj Correct A2 Short-circuit current A1 B1 H3DS-MLj A2 The H3DS Series is provided with a transformerless power supply system. Input Wires The input wires must be as short as possible. If the floating capacity of wires exceeds 2,000 pF (approx for cables with 120 pF/m), the operation will be affected. Pay particular attention when using shielded cables ...

Related keywords