3RP15051AP30 SIEMENS, 3RP15051AP30 Datasheet - Page 27

TIMER, MULTIFUNCTION

3RP15051AP30

Manufacturer Part Number
3RP15051AP30
Description
TIMER, MULTIFUNCTION
Manufacturer
SIEMENS
Datasheet

Specifications of 3RP15051AP30

Contact Configuration
SPCO
Nom Input Voltage
240V
Delay Time Range
0.5s To 10s
Adjustment Type
Screwdriver Slot
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
240V
Coil Voltage Vdc Nom
24V
1) 1 CO contact each and 1 tripping delay time each for U
2) 1 CO contact each for phase sequence correction.
* You can order this quantity or a multiple thereof.
Hysteresis Under-
Auto-RESET
--
Auto-RESET, closed-circuit principle, unbalance threshold 10 %
--
Analog adjustable, Auto-RESET, closed-circuit principle,
unbalance threshold 20 %
5 % of set
value
Digitally adjustable, Auto-RESET or manual RESET,
open-circuit or closed-circuit principle, unbalance threshold 5 ... 20 %
Adjustable
1 ... 20 V
Digitally adjustable, Auto-RESET or manual RESET,
open-circuit or closed-circuit principle
Adjustable
1 ... 20 V
Digitally adjustable, Auto-RESET or manual RESET,
open-circuit or closed-circuit principle
Adjustable
1 ... 20 V
Digitally adjustable, Auto-RESET or manual RESET,
open-circuit or closed-circuit principle, unbalance threshold 5 ... 20 %
Adjustable
1 ... 20 V
Digitally adjustable, Auto-RESET or manual RESET,
open-circuit or closed-circuit principle, unbalance threshold 5 ... 20 %
Adjustable
1 ... 20 V
Monitoring of phase sequence
Monitoring of phase sequence, phase failure and phase unbalance
Monitoring of phase sequence, phase failure,
phase unbalance and undervoltage
Monitoring of phase sequence, phase failure, overvoltage and
undervoltage
Monitoring of phase sequence, phase and N conductor failure,
overvoltage and undervoltage
Automatic correction of the direction of rotation in case of wrong
phase sequence, phase failure, phase unbalance, overvoltage and
undervoltage
Automatic correction of the direction of rotation in case of wrong
phase sequence, phase and N conductor failure, phase unbalance,
overvoltage and undervoltage
voltage
detec-
tion
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Over-
voltage
detec-
tion
No
No
No
No
Yes
Yes
Yes
Yes
ON-delay Tripping
--
0 ... 20
--
--
--
--
--
--
3UG Monitoring Relays for Electrical and Additional Measurements
delay
--
--
0.1 ... 20
0.1 ... 20
0.1 ... 20
0.1 ... 20
0.1 ... 20
0.1 ... 20
1)
1)
Auxiliary
contacts
Version
CO
contact
1
2
1
2
1
2
1
2
2
2
2
2
2
2
1)
1)
2)
2)
min
and U
Rated control
supply voltage
U
V
AC 160 … 260 A
AC 320 … 500 A
AC 420 … 690 A
AC 160 … 690 A
AC 160 … 690 A
AC 160 … 690 A
AC 160 … 690 A
AC 160 … 690 A
AC 160 … 690 A
AC 160 … 690 A
s
max
.
DT
A
A
A
A
Spring-loaded terminal
Order No.
3UG45 11-2AN20
3UG45 11-2BN20
3UG45 11-2AP20
3UG45 11-2BP20
3UG45 11-2AQ20
3UG45 11-2BQ20
3UG45 12-2AR20
3UG45 12-2BR20
3UG45 13-2BR20
3UG46 14-2BR20
3UG46 15-2CR20
3UG46 16-2CR20
3UG46 17-2CR20
3UG46 18-2CR20
Monitoring Relays
Price
per PU
PU
(UNIT,
SET, M)
Siemens LV 1 · 2006
1
1
1
1
1
1
1
1
1
1
1
1
1
1
PS*
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
Line monitoring
PG
101
101
101
101
101
101
101
101
101
101
101
101
101
101
Weight
per PU
approx.
kg
7/43
0.147
0.147
0.147
0.147
0.147
0.147
0.147
0.147
0.147
0.147
0.140
0.147
0.147
0.147

Related parts for 3RP15051AP30