3RP15051AP30 SIEMENS, 3RP15051AP30 Datasheet - Page 49

TIMER, MULTIFUNCTION

3RP15051AP30

Manufacturer Part Number
3RP15051AP30
Description
TIMER, MULTIFUNCTION
Manufacturer
SIEMENS
Datasheet

Specifications of 3RP15051AP30

Contact Configuration
SPCO
Nom Input Voltage
240V
Delay Time Range
0.5s To 10s
Adjustment Type
Screwdriver Slot
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
240V
Coil Voltage Vdc Nom
24V
Thermistor motor protection relays for PTC thermistors
(Type A PTCs)
• Monostable version with closed-circuit principle, triggers in
1) The unit can be reset with the RESET button or by disconnecting the
2) For more information on protection against voltage failure,
* You can order this quantity or a multiple thereof.
3RN10 12-2CK00
Compact signal evaluation units, width 22.5 mm, 1 LED
Standard evaluation units, width 22.5 mm, 2 LEDs
Evaluation units for 2 sensor circuits, warning and switching off,
width 22.5 mm, 3 LEDs
Evaluation units for 6 sensor circuits, multiple motor protection,
width 45 mm, 8 LEDs
Bistable evaluation units, width 22.5 mm
the event of control supply voltage failure
control supply voltage.
see Catalog LV 1 T.
RESET
Terminal A1 is jumpered with the
root of the changeover contact
Auto
Auto
Manual/remote
Short-circuit detection for sensor circuit
Manual/remote
Non-volatile
Manual/Auto/
Remote
Non-volatile
Manual/Auto/
Remote
Non-volatile
indication in sensor circuit; wide-range voltage with screw
connection with safe isolation
Manual/Auto/
Remote
Test/RESET button, non-volatile
Manual/Auto/
Remote
Test/RESET button, non-volatile
Manual/Auto/
Remote
Test/ RESET button, non-volatile
Short-circuit and open-circuit detection and indication in
sensor circuit
Manual/Auto/
Remote
2)
2)
2)
, short-circuit detection in sensor circuit
; short-circuit and open-circuit detection and
1)
1)
Contacts
1 CO
1 NO + 1 NC
2 CO
2 CO,
gold-plated
1 NO + 1 NC
2 CO
2 CO,
gold-plated
1 NO + 1 NC
2 CO
2 CO,
gold-plated
2 CO
2 CO,
gold-plated
1 NO + 1 CO
1 NO + 1 NC
2 CO
2)
2)
2)
Rated control supply
voltage U
V
AC/DC 24
AC 110
AC 230
AC/DC 24
AC 110
AC 230
AC/DC 24 … 240
AC/DC 24
AC 110 …
AC 230
AC/DC 24
AC/DC 24
AC 110 / 230
AC/DC 24
AC 110
AC 230
AC/DC 24
AC/DC 24
AC 110 / 230
AC/DC 24
AC 110
AC 230
AC/DC 24
AC/DC 24
AC/DC 24 … 240
AC/DC 24 … 240
AC/DC 24 … 240
AC/DC 24 … 240
AC/DC 24 … 240
s
50/60 Hz
• PTB01 ATEX approval, see Catalog LV 1 T.
• 3RN10 13-.BW01: bistable version, does not trigger in the
• All units except for 24 V AC/DC feature electrical isolation
DT
A
B
B
A
B
A
A
C
C
C
C
}
A
C
C
B
C
A
B
C
C
C
C
A
}
C
B
B
B
event of control supply voltage failure
Spring-loaded terminal
Order No.
3RN10 00-2AB00
3RN10 00-2AG00
3RN10 00-2AM00
3RN10 10-2CB00
3RN10 10-2CG00
3RN10 10-2CM00
3RN10 10-2CW00
3RN10 10-2BB00
3RN10 10-2BG00
3RN10 10-2BM00
3RN10 10-2GB00
3RN10 11-2CB00
3RN10 11-2CK00
3RN10 11-2BB00
3RN10 11-2BG00
3RN10 11-2BM00
3RN10 11-2GB00
3RN10 12-2CB00
3RN10 12-2CK00
3RN10 12-2BB00
3RN10 12-2BG00
3RN10 12-2BM00
3RN10 12-2GB00
3RN10 13-2BB00
3RN10 13-2BW00
3RN10 13-2GW00
3RN10 22-2DW00
3RN10 62-2CW00
3RN10 13-2BW01
3RN1 Thermistor Motor Protection
Monitoring Relays
Price
per PU
PU
(UNIT,
SET, M)
Siemens LV 1 · 2006
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
PS*
For PTC sensors
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
PG
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
Weight
per PU
approx.
kg
7/65
0.104
0.153
0.153
0.116
0.153
0.159
0.127
0.137
0.139
0.190
0.139
0.125
0.164
0.138
0.190
0.192
0.154
0.125
0.161
0.130
0.130
0.181
0.140
0.140
0.151
0.143
0.147
0.251
0.139