3RP15051AP30 SIEMENS, 3RP15051AP30 Datasheet - Page 51

TIMER, MULTIFUNCTION

3RP15051AP30

Manufacturer Part Number
3RP15051AP30
Description
TIMER, MULTIFUNCTION
Manufacturer
SIEMENS
Datasheet

Specifications of 3RP15051AP30

Contact Configuration
SPCO
Nom Input Voltage
240V
Delay Time Range
0.5s To 10s
Adjustment Type
Screwdriver Slot
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
240V
Coil Voltage Vdc Nom
24V
Application
Classification of a machine in categories acc. to EN 954-1
The 98/37/EG machinery directive stipulates that every machine
must comply with the applicable guidelines and standards.
Measures must be taken to keep the risk to persons as small as
possible.
The first step is for the project engineer to perform a risk
evaluation according to EN 1050 "Guidelines for risk
assessment". The ambient conditions of the machine have to be
considered, for example. Then any overall risk must be
evaluated. Risk evaluation must be performed in such a manner
that the procedure and conclusions can be retraced.
Possible selection of the categories acc. to EN 954-1
Summary of the requirements for categories acc. to EN 954-1
Starting point for risk assessment
of the safety related part of the control
Selection of the category
B, 1 to 4: Categories for parts of controllers with relevance for safety
Category
(not to be applied
in any specific
hierarchy)
B
1
2
3
4
Preferred categories for reference points
Possible categories which demand additional measures
Measures that may be excessive with respect to the particular risk
S1
S2
F1
F2
P1
P2
P1
P2
Summary of requirements
The safety related parts of controllers and/or their protective
devices as well as their components must be designed,
constructed, selected, assembled and combined in
accordance with the applicable standards in such a way that
they can resist the expected external influences.
The requirements of B must be met.
Well-proven components and well-proven safety principles
must be implemented.
The requirements of B must be met and well-proven safety
principles must be implemented.
The safety functions must be tested at regular intervals by the
machine control.
The requirements of B must be met and well-proven safety
principles must be implemented.
Parts with relevance for safety must be implemented such that
a single fault in any of these components does not result in loss
of the safety function, and whenever reasonably possible, the
individual fault is detected.
The requirements of B must be met and well-proven safety
principles must be implemented.
Parts with relevance for safety must be implemented such that
a single fault in any of these components does not result in loss
of the safety function, and the individual fault is detected
during or before the next activation of the safety function or, if
this is not possible, an accumulation of faults will not result in
loss of the safety function.
B
1
Category
2
3
4
S Severity of the injury
S1 Minor (usually reversible)
S2 Serious (normally
injury
irreversible) injury including
death
The dangers and possible technical measures for reducing risk
must also be specified.
After risk assessment, the category according to which the
safety circuits will be designed and implemented is specified
with the aid of EN 954-1.
This category defines the technical requirements for the
configuration of the safety equipment. There are five categories
(B, 1, 2, 3 and 4), whereby B (for Basic category) is the category
of the lowest risk and the one which defines the minimum
demands made on the control system.
F Frequency and/or duration of
System response
The occurrence of a fault can result
in loss of the safety function.
The occurrence of a fault can result
in loss of the safety function but the
probability of it occurring is less
than for Category B.
The occurrence of a fault can result
in loss of the safety function
between tests.
The loss of the safety function will
be detected by the test.
When the single fault occurs, the
safety function is always
maintained.
Some but not all faults are detected.
An accumulation of undetected
faults may lead to loss of the safety
function.
When faults occur, the safety
function is always maintained.
The faults are detected early to
prevent loss of the safety function.
the exposure to danger
F1 From rarely to often and/or
F2 From frequently to
short duration of exposure
constantly and/or long
duration of exposure
3TK28 Safety Relays
Siemens LV 1 · 2006
P Possibility to avoid the danger
P1 Possible under certain
P2 Hardly possible
Principles for achieving
safety
Mainly characterized by the
selection of components
Mainly characterized by the
structure
conditions
General data
7/67

Related parts for 3RP15051AP30