H2C-SB 240AC Omron, H2C-SB 240AC Datasheet
H2C-SB 240AC
Specifications of H2C-SB 240AC
Related parts for H2C-SB 240AC
H2C-SB 240AC Summary of contents
Page 1
... Note: Specify both the model number and supply voltage when ordering. Accessories (Order Separately) Timer Track mounted socket H2C-8, H2C-8R P2CF-08, PF085A H2C, H2C-R PF113A Note: Track mounted socket can be used as a front connecting socket. Terminal Time-limit ...
Page 2
... Mechanical: 10,000,000 operations min. 500,000 operations min 250 VAC, resistive load at 1,800 operations/h) Electrical: See “Engineering Data” 20,000 hrs UL (File No. E52800) H2C series: approx. 180 g H2C-F series: approx. 270 g 7.5 min to 3 hrs 1. hrs min 0 hrs 5 to 120 min 0 hrs H2C ...
Page 3
... Note: For the types rated at 24 and 48 VAC, the timing operation indicator is not equipped. Load current (A) H2C-8R OFF-delay 8-pin Round Socket Set time Rt Rt: Resetting time H2C-(F)R Set time Rt Rt (see note) Rt: Resetting time H2C Power failure time (t) ...
Page 4
... H2C Dimensions Note: All units are in millimeters unless otherwise indicated. H2C/H2C-R/ H2C-8/H2C-8R H2C-F/H2C-FR Accessories (Order Separately) Track Mounted/Front Connecting Socket P2CF-08 Eight, M3.5 x 7.5 sem Two, 4.5 dia. holes Top View PF085A Eight, M3 sems Two, 4.5 dia. holes 4 For Flush Mounting 44 ...
Page 5
... Two, 3.5 dia socket mounting holes Terminal Arrangement (Bottom View) Terminal Arrangement (Bottom View) Mounting Holes Mounting Height of Timer with Socket Two 4.5 dia. holes Mounting Height of Timer with Socket Mounting Height of Timer with Socket Mounting Height of Timer with Socket H2C 5 ...
Page 6
... Mounting Track (Meets DIN EN50022) PFP-100N/PFP-50N (see note) Note: This dimension applied to PFP-50N. End Plate PFP-M H2C (with PF113A) (See note) Note: For a load current max., a spacer and an end plate are not required. For a load current one spacer or an end plate is required. ...
Page 7
... The protective cover shields the front panel, particular- ly the time setting section, from dust, dirt, and water, as well as prevents the set value from being altered due to accidental contact with the time setting knob. H2C-8R OFF-delay 8-pin Round Socket H2C-(F)R H2C 7 ...
Page 8
... A B Electrical Set The motor and clutch do not need to be reset simultaneously. Use the voltage applied to the clutch for resetting with the H2C-R. Do not allow power to be continuously applied to the motor and clutch for extended periods of time. Others Do not turn the operation time setting knob beyond the range of the scale ...