E2E2-X5MB1M1 Omron, E2E2-X5MB1M1 Datasheet

E2E2-X5MB1 W/ M12 CONNECTOR

E2E2-X5MB1M1

Manufacturer Part Number
E2E2-X5MB1M1
Description
E2E2-X5MB1 W/ M12 CONNECTOR
Manufacturer
Omron
Datasheet

Specifications of E2E2-X5MB1M1

Rohs Compliant
YES
Sensor Input
Inductive
Sensing Range
5mm
Supply Voltage Range Dc
12V To 24V
A New Series of Easy-to-use
and Tough E2E/E2E2 Models
Long-size E2E2 Proximity Sen-
sor Conforms to CENELEC
• Ideal for a variety of applications.
• With a metal connector that can be tightened
• With an easy-to-see indicator, deeper mounting
• New 3-dia. size (sensing distance: 0.6 mm) added to
<READ AND UNDERSTAND THIS CATALOG>
Please read and understand this catalog before purchasing
the products. Please consult your OMRON representative if
you have any questions or comments.
Ordering Information
E2E
DC 2-wire/Pre-wired Models
Note 1. In addition to the above models, E2E-X@@15 models (e.g., E2E-X3D15-N), which are different in frequency from the above models, are
Yes
No
securely and a cable protector.
holes, and tightening flats for wrenches.
the lineup.
output function
Cylindrical Proximity Sensor
E2E/E2E2
Self-diagnostic
2. E2E models with a robotics cable are available as well. The model number of a model with a robotics cable has the suffix “-R”
3. Cables with a length of 5 m are also available. Specify the cable length at the end of the model number (e.g., E2E-X3D1-N 5M).
available.
(e.g., E2E-X3D1-R).
Shielded
Unshielded
Shielded
Unshielded
Size
M12
M18
M30
M12
M18
M30
M8
M12
M18
M30
M8
M12
M18
M30
3 mm
7 mm
10 mm
8 mm
14 mm
20 mm
2 mm
3 mm
7 mm
10 mm
4 mm
8 mm
14 mm
20 mm
Sensing distance
E2E-X3D1S (See note 1.)
E2E-X7D1S (See note 1.)
E2E-X10D1S (See note 1.)
E2E-X8MD1S (See note 1.)
E2E-X14MD1S (See note 1.)
E2E-X20MD1S (See note 1.)
E2E-X2D1-N (See notes 2 and 3.)
E2E-X3D1-N (See notes 1, 2 and 3.)
E2E-X7D1-N (See notes 1, 2 and 3.)
E2E-X10D1-N (See notes 1, 2 and 3.) E2E-X10D2-N
E2E-X4MD1 (See notes 2 and 3.)
E2E-X8MD1 (See notes 1, 2 and 3.)
E2E-X14MD1 (See notes 1, 2 and 3.)
E2E-X20MD1 (See notes 1, 2 and 3.
E2E/E2E2
NO
Cylindrical Proximity Sensor
Model
---
---
---
---
---
---
E2E-X2D2-N (See note 3.)
E2E-X3D2-N (See note 3.)
E2E-X7D2-N (See note 3.)
E2E-X4MD2
E2E-X8MD2
E2E-X14MD2
E2E-X20MD2
NC
1

Related parts for E2E2-X5MB1M1

E2E2-X5MB1M1 Summary of contents

Page 1

... Cylindrical Proximity Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Proximity Sen- sor Conforms to CENELEC • Ideal for a variety of applications. • With a metal connector that can be tightened securely and a cable protector. • With an easy-to-see indicator, deeper mounting holes, and tightening flats for wrenches. ...

Page 2

... The connector pin assignments of each new E2E DC 2-wire conforms to IEC947-5-2 Table III. The following E2E models with conventional connector pin assignments are available as well. Size Operation mode Shielded M12 NO NC M18 NO NC M30 NO NC E2E/E2E2 2 Cylindrical Proximity Sensor Size Sensing distance M12 3 mm E2E-X3D1S-M1 M18 7 mm E2E-X7D1S-M1 M30 10 mm E2E-X10D1S-M1 M12 8 mm ...

Page 3

... E2E-X10F1 E2E-X10F2 Un- shielded Note 1. Models with a different frequency are also available. These models are E2E-X@Y@5 (e.g., E2E-X5Y15). 2. Cables with a length are also available. Specify the cable length at the end of the model number (e.g., E2E-X2Y1 5M). E2E/E2E2 Sensing Output distance configuration NPN NO E2E-X2ME1 (See note 2 ...

Page 4

... NPN NO NPN NC PNP NO PNP NC M8 Shielded M8 1.5 mm NPN NO NPN NC PNP NO PNP NC Un NPN NO shielded NPN NC PNP NO PNP NC E2E/E2E2 4 Cylindrical Proximity Sensor AC 2-wire/Connector Models Output Model E2E-X1R5E1-M1 Shielded M12 E2E-X1R5E2-M1 E2E-X1R5F1-M1 E2E-X1R5F2-M1 E2E-X2E1-M1 E2E-X2E2-M1 E2E-X2F1-M1 Un- E2E-X2F2-M1 shielded E2E-X5E1-M1 E2E-X5E2-M1 E2E-X5F1-M1 E2E-X5F2-M1 ...

Page 5

... Model E2E2-X3D1 E2E2-X3D2 E2E2-X7D1 E2E2-X7D2 E2E2-X10D1 E2E2-X10D2 E2E2-X8MD1 E2E2-X8MD2 E2E2-X14MD1 E2E2-X14MD2 E2E2-X20MD1 E2E2-X20MD2 Model E2E2-X2C1 E2E2-X2C2 E2E2-X2B1 E2E2-X2B2 E2E2-X5C1 E2E2-X5C2 E2E2-X5B1 E2E2-X5B2 E2E2-X10C1 E2E2-X10C2 E2E2-X10B1 E2E2-X10B2 E2E2-X5MC1 E2E2-X5MC2 E2E2-X5MB1 E2E2-X5MB2 E2E2-X10MC1 E2E2-X10MC2 E2E2-X10MB1 E2E2-X10MB2 E2E2-X18MC1 E2E2-X18MC2 E2E2-X18MB1 E2E2-X18MB2 Cylindrical Proximity Sensor 5 ...

Page 6

... Sensing distance Operation mode Model E2E2-X2C1-M1 E2E2-X2C2-M1 E2E2-X2B1-M1 E2E2-X2B2-M1 E2E2-X5C1-M1 E2E2-X5C2-M1 E2E2-X5B1-M1 E2E2-X5B2-M1 E2E2-X10C1-M1 E2E2-X10C2-M1 E2E2-X10B1-M1 E2E2-X10B2-M1 E2E2-X5MC1-M1 E2E2-X5MC2-M1 E2E2-X5MB1-M1 E2E2-X5MB2-M1 E2E2-X10MC1-M1 E2E2-X10MC2-M1 E2E2-X10MB1-M1 E2E2-X10MB2-M1 E2E2-X18MC1-M1 E2E2-X18MC2-M1 E2E2-X18MB1-M1 E2E2-X18MB2-M1 Model E2E2-X2Y1 E2E2-X2Y2 E2E2-X5Y1 E2E2-X5Y2 E2E2-X10Y1 E2E2-X10Y2 E2E2-X5MY1 E2E2-X5MY2 E2E2-X10MY1 E2E2-X10MY2 E2E2-X18MY1 E2E2-X18MY2 ...

Page 7

... AC 2-wire/Connector Models Size Shielded M12 2 mm M18 5 mm M30 10 mm Unshielded M12 5 mm M18 10 mm M30 18 mm Sensing distance Operation mode E2E/E2E2 Model E2E2-X2Y1-M4 E2E2-X2Y2-M4 E2E2-X5Y1-M4 E2E2-X5Y2-M4 E2E2-X10Y1-M4 E2E2-X10Y2-M4 E2E2-X5MY1-M4 E2E2-X5MY2-M4 E2E2-X10MY1-M4 E2E2-X10MY2-M4 E2E2-X18MY1-M4 E2E2-X18MY2-M4 Cylindrical Proximity Sensor 7 ...

Page 8

... The residual voltage of each E2E model with the model number suffix “-M1J-T” When connecting an E2E model with the suffix “- M1J-T” device, make sure that the device can withstand the residual voltage. 4. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM standard. E2E/E2E2 8 Cylindrical Proximity Sensor ...

Page 9

... E2E-X2ME@/ E2E-X2E@/ E2E-X5ME ± 10 ± 4.0 mm Iron Iron 1.5 kHz 0.4 kHz 2 1,000 m/s 10 times each and Z directions Approx Approx Brass-nickel plated ) E2E/E2E2 M18 Shielded Unshielded Shielded E2E-X5E@/ E2E-X10ME@/ E2E-X10E ± 10 ± 10 ± 8.0 mm Iron Iron Iron 0.6 kHz ...

Page 10

... Note 1. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM standard. E2E/E2E2 10 Cylindrical Proximity Sensor 3 dia ...

Page 11

... C in the temperature range of –40 ° ° C ± 10% max. of sensing distance at 23 ° the temperature range of –25 ° ° 1,000 m/s 10 times each and Z directions Approx Approx Brass-nickel plated E2E/E2E2 M18 Shielded Unshielded Shielded E2E-X5Y@ E2E-X10MY@ E2E-X10Y ± ...

Page 12

... Power supply voltage waveform: Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset. 3. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM standard. E2E/E2E2 12 Cylindrical Proximity Sensor ...

Page 13

... Accessories Instruction manual Note 1. Use the E2E2 within the range in which the setting indicator (green LED) is lit (except D2 models). 2. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. ...

Page 14

... E2E2-X@C@/B@ DC 3-wire Models Size Type Shielded Item E2E2-X2C ± 10% Sensing distance Set distance 0 to 1.6 mm Differential travel 10% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.) Standard sensing Iron object 1 mm Response speed (See 1 ...

Page 15

... Instruction manual Note 1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is –25 ° ° When using an M18-or M30-sized E2E2 within an ambient temperature of 70 ° ° C, make sure that the E2E2 has a control output 200 mA maximum. ...

Page 16

... E2E-X3 E2E- −20 −15 −10 − Distance Y (mm) Unshielded Models E2E-X@MD E2E-X20M 15 E2E-X14M E2E-X8M 5 E2E-X4M 0 −30 −20 − Distance Y (mm) E2E/E2E2 16 Cylindrical Proximity Sensor E2E-X@E@/F@ E2E-X@ −15 −10 − Distance Y (mm) E2E-X@ME@/F@ E2E-X@MY E2E-X18M 15 E2E-X10M 10 E2E-X5M E2E-X2M 5 0 −30 −20 −10 ...

Page 17

... VAC 100 VAC 24 VDC 100 Load current (mA) 100 VAC Residual output voltage Proximity Sensor Residual load voltage Load current (mA) E2E/E2E2 E2E-X@T1 DC/AC Supply voltage (V) 200 VAC Residual output voltage Proximity Sensor 100 VAC Residual load voltage OFF Load current (mA) ...

Page 18

... Brass Aluminum Copper Side length of sensing object d (mm) E2E-X14MD Iron Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) E2E/E2E2 18 Cylindrical Proximity Sensor E2E-X3D@ E2E-X3T1 Iron Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) E2E-X4MD Iron ...

Page 19

... Stainless steel 0.5 (SUS304) Brass 0.4 Aluminum 0 Side length of sensing object d (mm) E2E/E2E2 E2E-X10E@F@ E2E-X10Y@ Iron Stainless steel (SUS304 Aluminum Side length of sensing object d (mm) E2E-X10ME@/F@ E2E-X10MY Stainless steel (SUS304 Aluminum Side length of sensing object d (mm) E2E-CR8 Iron ...

Page 20

... Distance Y (mm) Leakage Current (Typical) E2E2-X@D@ Supply voltage (V) E2E/E2E2 20 Cylindrical Proximity Sensor E2E2-X@C@/B@ E2E2-X@Y@ 3.0 2.5 Y 2.0 X E2E2-X2 1.5 1.0 0 -15 - Distance Y (mm) E2E2-X@MC@/B@ E2E2-X@MY Distance Y (mm) E2E2-X@Y@ Proximity Protective Sensor resistance (when OFF) AC power supply Supply voltage ( ...

Page 21

... Residual load voltage OFF Load current (mA) E2E2-X7D@ Iron Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) E2E/E2E2 200 VAC Residual output voltage Proximity Sensor 200 VAC Residual load voltage OFF Load current (mA) E2E2-X10D@ Iron Stainless steel (SUS304) Brass ...

Page 22

... Brass Aluminum Side length of sensing object d (mm) E2E2-X10MC@/B@ E2E2-X10MY@ Iron Stainless steel (SUS304) Brass t-=1 mm Aluminum Side length of sensing object d (mm) E2E2-X20MD@ Iron Stainless steel (SUS304) Brass Aluminum Copper t=1 mm Side length of sensing object d (mm) E2E2-X10C@/B@ E2E2-X10Y@ Iron Stainless steel (SUS304) ...

Page 23

... Constant current output is 1 mA. ** When connecting circuit. *** Pin contact, and pin contact. E2E-C/X@B@ PNP Open-collector Output Load Proximity sensor main circuit E2E-CR6@ has no 100-Ω resistance. E2E/E2E2 E2E-X@D1S With Diagnostic Output 4 Brown Load (0 V) Load Proximity sensor Orange (diagnostic main output) ...

Page 24

... Load Proximity sensor main circuit Blue 3 E2E/E2E2 24 Cylindrical Proximity Sensor E2E-X@T1 AC/DC 2-wire Models Brown 3 (or 1) Load Blue 4 (or 2) E2E2-X@B@ DC 3-wire Models + V Proximity sensor main circuit 100 Ω Pin contact, and pin contact. Brown 24 to 240 VDC Load 48 to 240 VAC ...

Page 25

... Control output Diagnostic output (see note) E2E-X@F@ PNP Output Operation indicator (red) Control output between black and blue lines Output voltage between black and blue lines E2E/E2E2 Sensing area Proximity Sensor ON Operation indicator (red) OFF ON Control output OFF Sensing ...

Page 26

... Sensing object E2E2-X@C@/B@ DC 3-wire Models NPN/PNP Open-collector Output Yes Sensing object No ON Operation OFF indicator (red) ON Control output OFF E2E2-X@Y@ AC 2-wire Models Yes Sensing object No ON Operation OFF indicator (red) ON Control output OFF E2E/E2E2 26 Cylindrical Proximity Sensor NC Models Non-sensing area ...

Page 27

... E2E-X@E@ DC 3-wire Models Brown Black Blue 24 VDC E2E-X@E@ DC 3-wire Models Brown Black 24 VDC Blue E2E/E2E2 E2E-X@D1-M1J-T DC 2-wire Models (No Polarity) E2E-X@Y@ AC 2-wire Models E2E-X@T1 AC/DC 2-wire Models Brown Load Power supply Blue Note: There is no need to be ...

Page 28

... E2E2-X@Y@ AC 2-wire Models Brown Load Power supply Blue Note: The load can be connected as shown in the above diagrams. Connected to PC E2E2-X@D@ DC 2-wire Models Brown Blue 24 VDC E2E/E2E2 28 Cylindrical Proximity Sensor Brown Power supply Blue Load E2E2-X@C@ DC 3-wire Models Brown Black Blue 24 VDC ...

Page 29

... Note: Terminals 3 and 4 are not used. Load Note: Terminal 1 is not used. (Self-diagnostic output) Load Load Load Note: Terminals 2 and 3 are not used. Load Note: Terminals 3 and 4 are not used. E2E/E2E2 Pin arrangement Load or Load Load Load Load Note: Terminals 1 is not used. Load ...

Page 30

... E2E-X@E/F@-M@ DC 3-wire Models Connector Operation mode M12 E2E/E2E2 30 Cylindrical Proximity Sensor Applicable models E2E-X@E1-M1 Load E2E-X@F1-M1 Load E2E-X@E2-M1 Load E2E-X@F2-M1 Load E2E-X@E1-M3 Load E2E-X@F1-M3 Load E2E-X@E2-M3 Load E2E-X@F2-M3 Load Pin arrangement Note: Terminal 2 is not used. Note: Terminal 2 is not used. ...

Page 31

... Refer to the following to mount the E2E-CR6, -CR8 and E2E-C1 non-screw models. Tighten the screw to a torque of 0.2 N·m maximum to secure the E2E-CR6, -CR8 and a torque of 0.4 N·m maximum to secure the E2E-C1. Part B Part A Part B Torque 12 N·m E2E/E2E2 Pin arrangement Load DC 4 ...

Page 32

... Model E2E-X@D@ Shielded DC 2-wire E2E-X@T1 AC/DC 2-wire E2E2-X@D@ DC 2-wire Unshielded E2E-X@E@ Shielded E2E-X@F@ DC 3-wire E2E-X@Y@ AC 2-wire E2E2-X@B@ E2E2-X@C@ Unshielded DC 3-wire E2E2-X@Y@ AC 2-wire Model E2E-X@C@ Shielded E2E-X@B@ E2E-C@C@ E2E-C@B@ DC 3-wire E2E/E2E2 32 Cylindrical Proximity Sensor d dia. Item 4 ...

Page 33

... E2E-X10Y@ E2E-X10T1 Unshielded E2E-X20MD@ E2E-X18ME@/F@ E2E-X18MY@ E2E2 Model M12 Shielded E2E2-X3D@ E2E2-X2C@/B@ E2E2-X2Y@ Unshielded E2E2-X8MD@ E2E2-X5MC@/B@ E2E2-X5MY@ M18 Shielded E2E2-X7D@ E2E2-X5C@/B@ E2E2-X5Y@ Unshielded E2E2-X14MD@ E2E2-X10MC@/B@ E2E2-X10MY@ M30 Shielded E2E2-X10D@ E2E2-X10C@/B@ E2E2-X10Y@ Unshielded E2E2-X20MD@ E2E2-X18MC@/B@ E2E2-X18MY@ Model No. Model No. E2E/E2E2 Cylindrical Proximity Sensor 33 ...

Page 34

... E2E-X@T1 Unshielded AC/DC 2-wire E2E2-X@D@ DC 2-wire E2E-X@E@ Shielded E2E-X@F@ DC 3-wire Unshielded E2E-X@Y@ AC 2-wire E2E2-X@B@ E2E2-X@C@ DC 3-wire E2E2-X@Y@ AC 2-wire Model E2E-X@B@ Shielded E2E-X@C@ E2E-C@B@ E2E-C@C@ DC 3-wire Note: Values in parentheses apply to Sensors operating at different frequencies. E2E/E2E2 34 Cylindrical Proximity Sensor B A Item Item 3 dia. ...

Page 35

... Load Brown Incorrect Sensor Blue DC 2-wire Models The following diagram shows that the load is short-circuited while the polarity of the supply voltage imposed on the E2E/E2E2 is wrong, in which case the E2E/E2E2 may explode or burn. Load Brown (Load short-circuit) Incorrect Sensor Blue Brown Load ...

Page 36

... R ≤ V /(10 – Ω > (mW) S E2E/E2E2 36 Cylindrical Proximity Sensor Environment Water Resistivity Do not use the Proximity Sensor underwater, outdoors the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained ...

Page 37

... V L Sensors) (V) Therefore voltage, the load will not operate. Correct A maximum of three Proximity Sensors can be connected in series provided that the supply voltage Load is 100 V minimum. Load V s × 100 V E2E/E2E2 Cylindrical Proximity Sensor (20.4 V) – 17 (0.8 mA): OK leak (3 k Ω – V)]/R ...

Page 38

... Model Connection type AC 2-wire OR (parallel connection 3-wire AND (serial connection) E2E/E2E2 38 Cylindrical Proximity Sensor Method In principle, more than two Proximity Sensors cannot Incorrect be connected in parallel. Load Provided that Proximity Sensor A does not operate B with Proximity Sensor B simultaneously and there is no need to keep the load operating continuously, the Proximity Sensors can be connected in parallel ...

Page 39

... E2E-X10ME@-M1/ 25 F@-M1 27 E2E-X18ME@-M1/ 27 F@-M1 --- E2E-CR8@@-M5 36 --- E2E-X1@@- E2E-X1R5E@-M3/ 28 F@-M3 29 E2E-X2ME@-M3 29 /F@-M3 30 --- --- --- --- 30 --- --- 32 34 E2E/E2E2 AC 2-wire Figure Model No. Figure Model No. No. No. --- --- --- E2E-X1R5Y@ 7 E2E-X2Y@ 11 E2E-X3T1 E2E-X5Y@ 12 E2E-X7T1 E2E-X10Y@ 16 E2E-X10T1 15 E2E-X2MY@ 8 --- E2E-X5MY@ 12 E2E-X10MY@ 15 E2E-X18MY@ 17 --- --- --- E2E-X2Y@-M1 22 E2E-X5Y@-M1 24 ...

Page 40

... Models)/3 conductors (E Models) setting indicator (green); (Conductor cross section: 0 Models: diameter: 1.27 mm), Operation indicator (red) Standard length The cable can be extended (separate metal conduit 200 m (control output 100 m (diagnostic output). E2E/E2E2 40 Cylindrical Proximity Sensor Fig. 3: E2E-C1@@ 5.4 dia. Fig. 4: E2E-X1@@ 9.7 dia × ...

Page 41

... Models)/3 conductors (E Models) 2 (Conductor cross section: 0 Insulator diameter: 1.74 mm), Standard length The cable can be extended (separate metal conduit 200 m (control output 100 m (diagnostic output). E2E/E2E2 dia. Operation indicator (red) M12 × 1 Two 4-dia. vinyl-insulated round cable ...

Page 42

... M30 × 1.5 Two clamping nuts Toothed washer Note: D Models: Operation indicator (red), setting indicator (green Model: Operation indicator (red) E2E/E2E2 42 Cylindrical Proximity Sensor M12 Connector Models (Unshielded) Fig. 19: E2E-X4MD@-M1(G) E2E-X2ME@-M1/F@-M1 15 dia. M12 × Note: D Models: Operation indicator (red), setting indicator (green Model: Operation indicator (red) Fig ...

Page 43

... Operation indicator (red), M12 × 1 setting indicator (green) Two clamping nuts Toothed washer Operation indicator (red), M18 × 1 setting indicator (green) Two clamping nuts Toothed washer E2E/E2E2 19.0 M8, 3-pin connector M8 × 1 Two clamping nuts Two toothed washers Operating indicator M5 × 0 × 1 ...

Page 44

... Fig. 34: E2E-X10D1-M1GJ E2E-X10D1-M1J-T 42 dia. 36 Fig. 35: E2E-X20MD1-M1GJ 42 dia. 36 Mounting Holes F Dimensions 3 dia. 4 dia. F (mm) +0.3 +0.5 3.3 / dia. 4 E2E/E2E2 44 Cylindrical Proximity Sensor 14.8 dia. Operation indicator (red), M18 × 1 setting indicator (green) Two clamping nuts Toothed washer Operation indicator (red), setting indicator (green) M30 × ...

Page 45

... M30 × 1.5 Two clamping nuts Toothed washer Note: D Models: Operation indicator (red), setting indicator (green Model: Operation indicator (red) E2E2-X8MD@ E2E2-X5M dia dia. Note: D Models: Operation indicator (red Insulator diameter: 1.3 mm), setting indicator (green Model: Operation indicator (red) ...

Page 46

... Two clamping nuts Toothed washer E2E/E2E2 46 Cylindrical Proximity Sensor Connector Models (Unshielded) E2E2-X5MC@-M1/B@-M1 21 dia. 17 M12 x 1 Operation indicator (red) E2E2-X5MY@-M4 21 dia. 17 1/2-20unf Operation indicator (red) E2E2-X10MC@-M1/B@-M1 29 dia 10 24 M12 x 1 Operation indicator (red) E2E2-X10MY@-M4 29 dia ...

Page 47

... E2E2-X18MC@-M1/B@-M1 42 dia M12 x 1 Operation indicator (red) E2E2-X18MY@-M4 42 dia 1/2-20unf Operation indicator (red) M30 + 0.5 dia. 30.5 dia. 0 E2E/E2E2 M12 x 1 26.8 dia. Operation indicator (red) M30 x 1.5 Two clamping nuts Toothed washer 1/2-20unf 26.8 dia. Operation indicator (red) M30 x 1 ...

Page 48

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords