XACA201 SQUARE D, XACA201 Datasheet

no-image

XACA201

Manufacturer Part Number
XACA201
Description
PENDANT STATION 600VAC 10A XAC +OPTIONS
Manufacturer
SQUARE D
Datasheet

Specifications of XACA201

Rohs Compliant
NO
Product data sheet
Characteristics
Complementary
Mar 30, 2012
Control station colour
Connections - terminals
Mechanical durability
Cable entry
Contact code designation
[Ithe] conventional enclosed thermal current
[Ui] rated insulation voltage
[Uimp] rated impulse withstand voltage
Contacts operation
Resistance across terminals
Operating force
Short circuit protection
Rated operational power in W
Terminals description ISO n°1
Terminal identifier
Product weight
XACA201
pendant station XAC-A pistol grip - 2 push
buttons
Main
Range of product
Product or component
type
Control station name
Control station type
Enclosure material
Control type
Electrical circuit type
Enclosure type
Control station applica-
tion
Control station compo-
sition
Control button type
Contact block name
Mechanical interlocking
Yellow
Screw clamp terminals, connection capacity: 2 x 1.5 mm² with or without cable
end
Screw clamp terminals, connection capacity: 1 x 2.5 mm² with or without cable
end
1000000 cycles
Rubber sleeve with stepped entry, cable outer diameter: 7...15 mm
Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
10 A
600 V (degree of pollution: 3) conforming to IEC 60947-1
6 kV conforming to IEC 60947-1
Slow-break
<= 25 mOhm
13...15 N
10 A fuse protection by cartridge fuse type gG
65 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V, load factor
= 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
48 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V, load factor
= 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
40 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 120 V, load factor
= 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
(13-14)NO
(11-12)NC
(13-14)NO
0.27 kg
Harmony XAC
Pendant control station
XACA pistol grip
Double insulated
Polypropylene
Intuitive
Control circuit
Complete ready for use
Control of single speed hoist motor
2 pushbuttons
Second pushbutton 1 NO lower, slow
First pushbutton 1 NO raise, slow
ZB2BE101 for each direction
With mechanical interlocking
1

Related parts for XACA201

XACA201 Summary of contents

Page 1

... Resistance across terminals Operating force Short circuit protection Rated operational power in W Terminals description ISO n°1 Terminal identifier Product weight Mar 30, 2012 XACA201 pendant station XAC-A pistol grip - 2 push buttons Main Range of product Harmony XAC Product or component Pendant control station type ...

Page 2

Environment Standards Product certifications Protective treatment Ambient air temperature for operation Ambient air temperature for storage Vibration resistance Shock resistance Class of protection against electric shock IP degree of protection IK degree of protection 2 CSA C22 EN/IEC ...

Page 3

... Product data sheet Dimensions Drawings Dimensions (1) Internal Ø XACA201 3 ...

Page 4

... Product data sheet Connections and Schema Control of Single-Speed Reversing Motor 4 XACA201 ...

Page 5

... Operating rate: 3600 operating cycles/hour. Load factor: 0.5. Millions of operating cycles, AC-15 utilization category Ithe Thermal current (A) Current DC Supply Operating rate: 3600 operating cycles/hour. Load factor: 0.5. Power broken in W for 1 million operating cycles, DC-13 utilization category Voltage V Inductive circuit W XACA201 120 40 5 ...

Related keywords