G6K-2P 5DC Omron, G6K-2P 5DC Datasheet

RELAY, PCB, DPCO, 5VDC

G6K-2P 5DC

Manufacturer Part Number
G6K-2P 5DC
Description
RELAY, PCB, DPCO, 5VDC
Manufacturer
Omron
Datasheet

Specifications of G6K-2P 5DC

Coil Type
DC Coil, Monostable
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
5V
Coil Current
21.1mA
Coil Resistance
237ohm
Relay Mounting
PC Board
Contact Configuration
DPDT
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Surface Mounting Relay with the
World’s Smallest Mounting Area and a
Height of Only 5.2 mm
The above specifications are ensured as of August 1999.
Ordering Information
Model Number Legend
1.
2.
Note: 1. When ordering, add the rated coil voltage to the model number.
G6Kj-jj-j j VDC
DPDT
None: Single-side stable model
Subminiature model as small as 5.2 (H) x 6.5 (W) x
10 (L) mm is ideal for high-density mounting.
Low profile of 5.2 mm and weight of only 0.7 g
combine to improve mounting efficiency.
Models with inside-L surface mounting terminals
are available.
Consumes approximately 70% the power of a
conventional OMRON model and operates at a
current that is as low as 100 mW.
Surface mounting terminal models incorporate a
unique terminal structure with high infrared
irradiation efficiency which allows the terminal
temperature to rise easily when mounting the IRS,
thus ensuring excellent soldering.
Ensures a dielectric strength of 1,500 VAC and
conforms to FCC Part 68 (i.e., withstanding an
impulse withstand voltage of 1,500 V for 10 x
160 !s).
New-Y models offer an impulse withstand voltage
of 2,500 V for 2 x 10 !s (conforms to Bellcore
specifications) by optimizing the distance between
coil and contacts.
Conforms to UL1950 (File No. E41515)/CSA C22.2
No. 950 (File No. LR24825)
Relay function
U:
Contact form
2:
Surface Mounting Relay
2. When ordering tape packing, add “-TR” to the model number.
1
Single-winding latching model
DPDT
Example: G6K-2F 12 VDC
Example: G6K-2F-TR 12 VDC
Be sure since “-TR” is not part of the relay model number, it is not marked on the relay case.
2
3
Fully sealed
4
y sea ed
5
Classification
Through-hole terminal
Surface mounting
S
t
terminal
Tape packing
ace
i
Rated coil voltage
l
o
g
Inside-L
Outside-L
3.
4.
5.
G6K-2P
G6K-2G
G6K-2F
None: UL, CSA
Single-side
stable
Terminal shape
F:
G:
P:
Approved standards
Y:
Rated Coil Voltage
3, 4.5, 5, 12, 24 VDC
Outside-L surface mounting terminal
Inside-L surface mounting terminal
PCB terminal
Does not conform to Bellcore specifications
UL, CSA
Conforms to Bellcore specifications: 2,500 V for 2 x 10 !s
G6KU-2P-Y
G6KU-2G-Y
G6KU-2F-Y
Single-winding
latching
G6K-2P-Y
G6K-2G-Y
G6K-2F-Y
Single-side stable Bellcore:
2, 500 V for 2x10 !s
G6K
RC
1

Related parts for G6K-2P 5DC

G6K-2P 5DC Summary of contents

Page 1

... Note: 1. When ordering, add the rated coil voltage to the model number. Example: G6K-2F 12 VDC Rated coil voltage 2. When ordering tape packing, add “-TR” to the model number. Example: G6K-2F-TR 12 VDC Tape packing Be sure since “-TR” is not part of the relay model number not marked on the relay case. Model Number Legend ...

Page 2

... Note: 1. The rated current and coil resistance are measured at a coil temperature of 23#C with a tolerance of $10%. 2. The operating characteristics are measured at a coil temperature of 23#C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. Single-side Stable Models (Bellcore Version) G6K-2F-Y, G6K-2G-Y, G6K-2P-Y Rated voltage Rated current Coil resistance ...

Page 3

... Approx. 100 mW Resistive load 0 125 VAC VDC 1 A 125 VAC, 60 VDC 1 A Single-side stable models (double-pole) G6K-2F, G6K-2G, G6K-2P G6K-2F-Y, G6K-2G-Y, G6K-2P-Y 2,500 !s), 1,500 V (10 x 160 !s) 2 (approx. 100G) 2 (approx. 75G) 100,000 operations min. (with a rated load at 1,800 operations/hour) ...

Page 4

... Ambient temperature (#C) Ambient Temperature vs. Must Set or Must Reset Voltage G6KU-2G (F/P)-Y Max. estimated value Ambient temperature (#C) Electrical Life Expectancy (Contact Resistance) (see note) G6K-2G (F/P), G6K-2G (F/P)-Y NO Sample: G6K-2G contact Number of Relays Test conditions resistive load contact at 30 VDC with an operation rate of 50% ...

Page 5

... Sample: G6K-2G Must operate voltage Number of Relays: 10 Must release voltage External magnetic field (A/m) High-frequency Characteristics (Insertion Loss) G6K-2G (F/P), G6K-2G (F/P)-Y (Average value) Sample: G6K-2G Number of Relays: 10 Frequency (MHz) G6K Mutual Magnetic Interference G6K-2G (F/P), G6K-2G (F/P)-Y Must operate voltage ...

Page 6

... Note: Each value has a tolerance of $0.3 mm. G6K-2P Note: Each value has a tolerance of $0.3 mm. 6 Must Operate and Must Release Bounce Time Distribution (see note) G6K-2G (F/P) , G6K-2G (F/P)-Y Must operate bounce time Must release bounce time Sample: G6K-2G Number of Relays: 50 Time (ms) Mounting Dimensions (Top View) Tolerance: $0 ...

Page 7

... G6K-2G-Y Note: Each value has a tolerance of $0.3 mm. G6K-2P-Y Note: Each value has a tolerance of $0.3 mm. G6KU-2F-Y Note: Each value has a tolerance of $0.3 mm. G6KU-2G-Y Note: Each value has a tolerance of $0.3 mm. G6KU-2P-Y Note: Each value has a tolerance of $0.3 mm. Mounting Dimensions (Top View) Terminal Arrangement/ Internal Connections Tolerance: $0 ...

Page 8

... Industrial Association of Japan)) Reel type: RPM-16D (EIAJ) Relays per Reel: 900 1. Direction of Relay Insertion Top tape (cover tape) Carrier tape Emboss tape 2. Reel Dimensions 8 Stopper (green) 3. Carrier Tape Dimensions Pulling direction G6K-2F, G6K-2F-Y, G6KU-2F-Y Orientation mark Pulling direction G6K-2G, G6K-2G-Y, G6KU-2G-Y G6K ...

Page 9

... Land Visually check that the Relay is properly soldered. Approved Standards UL approval: UL1950 (File No. E41515) CSA approval: C22.2 No. 950 (File No. LR24825) Contact form Coil rating DPDT G6K-2G(F/P): G6K(U)-2G(F/P)- VDC Excessive amount of solder Contact rating VDC VDC 0 VDC 0 125 VAC G6K Number of test operations ...

Page 10

... G6K Precautions For general precautions, refer to the PCB Relays Catalog (X033). Familiarize yourself with the precautions and glossary before using the G6K. Correct Use Handling Leave the Relay unpacked until mounting it. Soldering Solder: JIS Z3282, H63A Soldering temperature: Approx. 250#C (260#C if the DWS method is used) Soldering time: Approx ...

Related keywords