LC1D38B7 TELEMECANIQUE, LC1D38B7 Datasheet

CONTACTOR, 18.5KW, 24VAC

LC1D38B7

Manufacturer Part Number
LC1D38B7
Description
CONTACTOR, 18.5KW, 24VAC
Manufacturer
TELEMECANIQUE
Datasheet

Specifications of LC1D38B7

Operating Voltage
24VAC
Switching Power Ac3
18.5kW
Switching Current Ac1
50A
Switching Current Ac3
38A
No. Of Poles
3
Contacts
1NO / 1NC
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
24V
Contact Configuration
1NO / 1NC
2.3
2
Dimensions
LC1-D09 … D18 (3-pole)
LC1-
b without add-on blocks
b1 with LAD-4BB
c without cover or add-on blocks
c1 with LAD-N or C (2 or 4 contacts)
c2 with LA6-DK10, LAD-6K10
c3 with LAD-T, R, S
(1) Including LAD-4BB
LC1-D40 … D65 (3-pole)
LC1-D65004, D40008 and D65008 (4-pole)
LC1-
a
b1 with LA4-Dp2
c without cover or add-on blocks
c1 with LAD-N (1 contact)
c2 with LA6-DK
c3 with LAD-T, R, S
LC1-D115 and D150 (3-pole)
LC1-D115004 (4-pole)
LC1-
a
b1 with LA4-DA2
c without cover or add-on blocks
c1 with LAD-N or C (2 or 4 contacts)
c2 with LA6-DK20
c3 with LAD-T, R, S
Selection:
pages 1/12 to 1/35
2/94
10
with LA4-Dp2
with LA4-DF, DT
with LA4-DR, DW, DL
with cover, without add-on blocks
with LAD-T, R, S and sealing cover
12
with LA4-DB3
with LA4-DF, DT
with LA4-DM, DR, DW, DL
with cover, without add-on blocks
with LAD-N or C (2 or 4 contacts)
with LAD-T, R, S and sealing cover
with LA4-DF, DT
with LA4-DM, DR, DL
with LA4-DW
with cover, without add-on blocks
with LAD-T, R, S and sealing cover
Minimum electrical
clearance
Minimum electrical
clearance
c1
c2
c3
c1
c2
c3
c
c
Characteristics:
pages 2/62 to 2/67
(LAD-8)
(LAD-8)
12,5
12,5
D09…
D18
77
94
110 (1)
119 (1)
126 (1)
84
86
117
129
137
141
D40…D65
75
135
142
150
114
119
139
147
159
167
171
D115 D115004 D115006 D150006 D1150046
D150
120 150
174 174
185 185
188 188
188 188
132 132
136 –
150 150
155 155
168 168
172 172
32
LA4
44
45
a
LA4
44
D093…
D183
99
107
123 (1)
132 (1)
139 (1)
84
86
117
129
137
141
TeSys contactors
Model d contactors
Control circuit: a.c.
References:
pages 2/74 to 2/77
12,5
(LAD-8)
120
174
185
188
188
115
150
155
168
172
D40008
85
135
142
150
125
139
147
159
167
171
D099…
D189
80
95.5
111.5 (1)
120.5 (1)
127.5 (1)
84
86
129
137
141
117
120
174
185
188
115
150
155
168
172
LC1-D80 and D95 (3-pole)
LC1-D80004 and D80008 (4-pole)
LC1-D25 … D38 (3-pole)
LC1-DT20 … DT60 (4-pole)
10
12
D80
D65004
85
135
135
142
150
125
130
150
158
170
178
182
155
174
185
188
188
115
150
155
168
172
D25…
D38
85
98
114 (1)
123 (1)
130 (1)
90
92
123
135
143
147
Minimum electrical
clearance
Minimum electrical
Minimum electrical
clearance
clearance
c1
c2
c3
c1
c2
c3
Schemes:
pages 2/98 and 2/99
c
c
D253
& D323
99
107
123 (1)
132 (1)
139 (1)
90
92
123
135
143
147
D95
D65008
85
135
142
150
125
130
150
158
170
178
182
10
Minimum electrical
clearance
DT20
& DT25
85
98
114
129
190
90
92
123
135
143
147
c1
c2
c3
c
(LAD-8)
(LAD-8)
D80004
96
135
142
150
125
150
158
170
178
182
DT203
& DT253
99
90
92
123
135
143
147
12,5
12,5
32
LAD-8
LA4
44
45
Schneider Electric
DT32…
DT60
91
98
100
131
143
151
155
a
LA4
44
D80008
96
135
142
150
140
150
158
170
178
182
LA4
12,5
(LAD-8)
a
DT323
& DT603
105
98
100
131
143
151
155

Related parts for LC1D38B7

LC1D38B7 Summary of contents

Page 1

Dimensions LC1-D09 … D18 (3-pole) Minimum electrical clearance LC1- b without add-on blocks b1 with LAD-4BB with LA4-Dp2 with LA4-DF, DT with LA4-DR, DW without cover or add-on blocks with cover, without ...

Page 2

Dimensions LC1-D09…D18 (3-pole) Minimum electrical clearance LC1 without cover or add-on blocks with cover, without add-on blocks c1 with LAD contacts) c2 with LA6-DK10 c3 with LAD-T, R, ...

Page 3

Mounting On mounting rail AM1-DP200, DR200 or AM1-DE200 (width 35 mm) LC1-D09…D38, DT20…DT60 2 c LC1- D09…D18 D25…D38 DT20 (AM1-DP200 or DR200) ( (AM1-DE200) (1) 96 d.c. control circuit 2 (AM1-DP200 or ...

Page 4

Mounting LC1-D09 to D38 and LC1-DT20…DT60 On 2 mounting rails DZ5-MB DZ5-ME8 c 15 LC1-D09…D38 and LC1-DT20…DT60 On pre-slotted mounting plate AM1-PA, PB AF1-EA4 G Control circuit: a.c. LC1- D09…D18 D25…D38 c with cover ...

Page 5

Schemes 3-pole contactors (References: pages 2/74 to 2/77) LC1-D09 to D150 2 4-pole contactors (References: pages 2/76 and 2/77) LC1 and LP1- D12004 to D80004 LC1-D115004 Front mounting add-on contact blocks Instantaneous auxiliary contacts (References: page 2/85) 2.3 1 N/O ...

Page 6

Schemes Front mounting add-on contact blocks Dust and damp protected instantaneous auxiliary contacts 2 N/O (24- N/C (24-50 V) LA1-DX20 LA1-DX02 Front mounting add-on contact blocks Time-delay auxiliary contacts (References: page 2/86) On-delay 1 N N/C ...

Page 7

Dimensions LC2-D09 to D38 2 x LC1-D09 to D38 LC2 LC1 (1) D09 to D18 D093 to D183 D09 to D18 c ...

Page 8

Schemes Reversing contactors for motor control, horizontally mounted LC2-D09…D150 Changeover contactor pairs, horizontally mounted LC2-DT20…DT60 Electrical interlocking of reversing contactors fitted with: mechanical interlock with integral electrical contacts LA9-Dppp02 01 – KM1 – KM2 02 – KM1 Low speed - ...

Related keywords