SI-MAG1MM BANNER ENGINEERING, SI-MAG1MM Datasheet

Photoelectric Sensor

SI-MAG1MM

Manufacturer Part Number
SI-MAG1MM
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Reedr
Datasheet

Specifications of SI-MAG1MM

Sensor Housing
Rectangular
Sensor Input
Optical
Sensing Range Max
3mm
Switch Terminals
Cable
Features
Coded Magnet, Switching Distance 3-14mm
10-ft Cable
Supply Current
Sensor Output
NO/NC
Brand/series
SI-MAG
Function
Proximity
Ip Rating
IP67
Primary Type
Proximity
Range, Measurement
14 mm
Technology
Reed
Termination
Cable
Voltage, Switching
30 VDC
Lead Free Status / Rohs Status
RoHS Exempt Product
*NOTES:
Printed in USA
Cable Opposite
SI-MAG1SM
SI-MAG1SMCO
SI-MAG2SM
SI-MAG3SM
• 9 m (30') cables are available for magnet sensors by adding suffix “W/30” to the model number of the cabled version
(e.g., SI-MAG1SM w/30).
Sensor*
Magnet
SI-MAG1MM
SI-MAG1MMHF
SI-MAG2MM
SI-MAG3MM
®
Magnetic Style Safety Switch Models
Machine Safety Switches
Magnet Style
Magnet
Coded
10/02
• Non-contact safety switches are the best choice for
• Tolerant of dirt buildup, sensing distance, and alignment
• System consists of three components:
• Magnet contains several differently-polarized magnets, and
• Easy installation; can be concealed for added defeat resistance
• Sensor reed switches provide diverse input to the controller
washdown applications; the switch components are sealed
and rated NEMA 4X, IEC IP67
sensor contains pole-stable reed contacts to minimize any
possibility of defeat
module
SI-MAG Series Magnetic Style Switch Features
SI-MAG1C
- Coded magnet
- Reed switch sensor
- Controller module
Controller
Sensor
Cable
(10 ft)
3 m
Min. ON
(0.12")
(0.31")
(0.16")
(0.12")
Switching Distance
3 mm
8 mm
4 mm
3 mm
P/N 49376 rev. B
Max OFF
14 mm
16 mm
(0.28" )
(0.55")
(0.63")
(0.32")
8 mm
7 mm

Related parts for SI-MAG1MM

SI-MAG1MM Summary of contents

Page 1

... Easy installation; can be concealed for added defeat resistance • Sensor reed switches provide diverse input to the controller module Magnetic Style Safety Switch Models Coded Magnet SI-MAG1MM SI-MAG1MMHF SI-MAG1C SI-MAG2MM SI-MAG3MM 10/02 Sensor Switching Distance Controller Cable Min ...

Page 2

... ISO 13849 (EN954-1). In addition, the user of Banner safety switches has the responsibility to ensure that all local, state, and national laws, rules, codes, and regulations relating to the use of Banner safety switches in any particular application are satisfied. Extreme care is urged that all legal requirements have been met and that all installations and maintenance instructions are followed ...

Page 3

... Route the sensor cable to the controller location. The controller must be installed inside an enclosure not designed for exposed wiring the user’s responsibility to house the controller in an enclosure with NEMA (or IEC) rating which is suitable for the operating environment ...

Page 4

... In addition, normally-closed safety contacts from each of the two safety switches must be individually connected to the two separate inputs of a 2-channel safety module or safety interface, as illustrated in Figure 1. This is required to provide monitoring for safety switch contact failure, and to provide the necessary reset routine, as required by ANSI B11 and NFPA 79 machine safety standards. CAUTION! Connection of Multiple Safety Switches to one Safety Module Input Channel ...

Page 5

... Confirmation that the sensor and magnet are not being used as an end stop, 4) Loosening of the sensor or magnet mounting hardware. 5) Verify that it is not possible to reach any hazard point through an opened guard (or any opening) before hazardous machine motion has completely stopped. In addition, we recommend that a qualified person check for the following on a periodic ...

Page 6

... Direction of Movement Alternate Direction of Approach movement is parallel to the plane of the sensing face Sensor Magnet Direction of Movement Figure 2a.Direction of Approach for SI-MAG1xx sensor/magnet pairs Normal Direction of Approach movement is perpendicular to the plane of the sensing face Magnet Sensor Direction of Movement Alternate Direction of Approach movement is parallel to the ...

Page 7

... Red - Sensor/Magnet out of position or open circuit in sensor wiring Housing Polycarbonate; Rated NEMA 1, IEC IP20 Mounting Mounts to standard 35 mm DIN rail track. Must be installed inside an enclosure rated NEMA 3, IEC IP54 or better. Wire Connections Screw terminals with pressure plates accept wire size: 0.2 mm Operating Temperature 0° ...

Page 8

... Magnet (3.1") Surface (3.5") (0.12") (2.7" (0.5") Figure 3c. SI-MAG1MM Magnet dimensions Magnet Surface 7 mm (0.3" (1.0 in (0.9" (1.1" (1.7") 10.5 mm (0.4") Magnet Surface 4.5 mm (0.2") ø (1.4" (0.4") ...

Related keywords