V600HS672M Omron, V600HS672M Datasheet

no-image

V600HS672M

Manufacturer Part Number
V600HS672M
Description
RFID Antenna
Manufacturer
Omron
Datasheet

Specifications of V600HS672M

For Use With
V600 RFID
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Innovative RFID Electronic Flags to
Replace Mechanical Flag and Kanban
Systems
• Doesn't need a program and can be used like a sensor.
• Advanced line construction at minimal cost.
• Saves space.
• Precise installation not required (Transmission distance:
• A verification function provided on multi-functional type.
• Addition of 16-bit models to the series responds to applica-
• Equipped with a wiring reduction mode and communications
• Both NPN and PNP output available.
• FCC certified.
Ordering Information/Specifications
■ Amplifier
2
Power supply
Current consumption 130 mA max.
Input
Output
Diagnostic functions Checks for CPU errors and transmission errors
Insulation resistance 50 MΩ max. (at 500 VDC) between cable terminals and case
Dielectric strength
100 mm max.).
tions from Kanban to quality control.
parity check function (16-bit models).
Intelligent Flag I/II
V600-HA
Item
Intelligent Flag I/II
Model
Type
24 VDC ±10%, ripple (p-p): 10%
Transistor output or contact output
Short-circuit current: 3 mA (typical) (IN terminal and 0-V short-circuit)
OFF voltage:
ON voltage:
Input impedance:
Applied voltage:
NPN open collector
output, 20 mA max. at
30 VDC, residual volt-
age: 2 V max.
500 VAC, 50/60 Hz for 1 min between cable terminals and case (leakage current: 1 mA max.)
V600-HAR91
Read-only (8-bit)
V600-HA
PNP open collector
output, 20 mA max.
at 30 VDC, residual
voltage: 2 V max.
15 to 30 VDC
0 to 5 VDC
8.2 kΩ
30 VDC max.
V600-HAR81
NPN open collector
output, 20 mA max. at
30 VDC, residual volt-
age: 2 V max.
V600-HAM91
Multi-functional (8-bit)
PNP open collector out-
put, 20 mA max. at 30
VDC, residual voltage: 2 V
max.
V600-HAM81
Transistor output
OFF voltage:
15 to 30 VDC
Input impedance:
8.2 kΩ
Short-circuit current:
3 mA (typical) (for 0-V short-circuit of
INHIBIT/TRG)
ON voltage:
0 to 5 VDC
Applied voltage:
30 VDC max.
NPN open collector output, 20 mA
max. at 30 VDC, residual voltage: 2 V
max.
Read-only (16-bit)
V600-HAR92

Related parts for V600HS672M

V600HS672M Summary of contents

Page 1

Intelligent Flag I/II V600-HA Innovative RFID Electronic Flags to Replace Mechanical Flag and Kanban Systems • Doesn't need a program and can be used like a sensor. • Advanced line construction at minimal cost. • Saves space. • Precise installation ...

Page 2

Type Read-only (8-bit) Item Model V600-HAR91 Vibration resistance Destruction 150 Hz, 0.3-mm double amplitude, with 4 sweeps of 8 min each in 3 directions Shock resistance Destruction: 294 m/s Ambient temperature −10 to 55°C (with no icing) Ambient ...

Page 3

Sensor Model V600-HS51 Shape Item Transmission frequency 530 kHz −10 to 60°C Ambient temperature −25 to 75°C Storage temperature Ambient humidity 35% to 95% Insulation resistance 50 MΩ (at 500 VDC) between cable terminal and case Dielectric strength 1,000 ...

Page 4

System Configuration Sensor (Cable length: fixed Connector connection Amplifier (Cable length: fixed to 0.5 m, with connector) interface Interface cable available in three lengths and 10 m (10 m max.) Host Programmable Controller, ...

Page 5

Characteristic Data (Typical) ■ Transmission Range Combinations with the V600-HS51 Sensor V600-HS51 & V600-D23P53 –8 – V600-HS51 & V600-D23P61 –15 –10 – ...

Page 6

Combinations with the V600-HS63 Sensor V600-HS63 & V600-D23P55 –30 –20 – V600-HS63 & V600-D23P66SP –50 –40 –30 –20 –10 0 ...

Page 7

Combinations with the V600-HS67 Sensor V600-HS67 & V600-D23P66N – 80 – 60 – 40 – V600-HS67 & V600-D23P72 Y Y 100 –100 ...

Page 8

... Output Circuit +DC Main circuit OUT 0 V The following OMRON products cannot be connected to this product. • CVM1-OD219, C20H, C28H, C40H, or C60H Programmable Controllers • Sensor Controllers other than from the S3D2 Series When using a contact output, pay careful attention to chattering and to the minimum switching current. Also note that the minimum switch- ing current may be specified for some solid-state outputs ...

Page 9

Power Supply Voltage Do not impose any voltage exceeding the rated voltage range. Doing so, or applying alternating current (100 VAC) may cause the product to explode or burn. Load Short-circuiting Do not short-circuit the load connected to the product ...

Page 10

Dimensions Note: All units are in millimeters unless otherwise indicated. Amplifier V600-HAR91/-HAR81 Two, mounting holes * 89 98 8.2 * Enlarged Section of Mounting Hole 4.4 30 5.5 30 30û 21 17.5 28.3 36.3 61.8 68.5 80 Vinyl-insulated round cord ...

Page 11

V600-HAM91/-HAM81 30 Two mounting 21 holes * 89 98 8.2 V600-HA 12 Intelligent Flag I/II * Enlarged Section of Mounting Hole 4.4 30 5.5 30˚ 17.5 28.3 36.3 44.3 52.3 61.8 68 Vinyl-insulated round cord 5.8-mm dia., 23-conductor ...

Page 12

V600-HAR92 30 Two, mounting 21 holes * 89 98 8.2 Sensor V600-HS51 M12X1 9.6 dia. 7 V600-HS61 30.5 18 Detection surface 10 * Enlarged Section of Mounting Hole 4.4 30 5.5 30˚ 17.5 28.3 36.3 44.3 61.8 68 ...

Page 13

V600-HS63 5 Power indicator (green) V600-HS67 Power indicator (green) 14 Interface Cable V600-A6@R (for V600-HAR91/-HAR81)) V600-HA 14 Intelligent Flag I/II Two, 4.5-dia. mounting holes 2-R5 4-R1 Bushing Case: ABS resin ...

Page 14

V600-A6@M (for V600-HAM91/-HAM81/-HAR92) Model L (m) V600-A60R/60M 2 V600-A61R/61M 5 V600-A62R/62M 10 +5 +100 330 ±5 20 ±5 20 ±5 Vinyl-insulated round cord 9-mm dia (7/0.2-mm dia.), 23-conductor cable, standard length Intelligent Flag I/II ...

Page 15

... The following are some examples of applications for which particular attention must be given. This is not intended exhaustive list Complete terms and conditions for product purchase and use are on Omron’s website at www.omron.com/oei – under the “About Us” tab, in the Legal Matters section. ...