GFL631T-3 INSTRUMENT TRANSFORMER, GFL631T-3 Datasheet - Page 13

GROUND FAULT CURENT

GFL631T-3

Manufacturer Part Number
GFL631T-3
Description
GROUND FAULT CURENT
Manufacturer
INSTRUMENT TRANSFORMER
Datasheet

Specifications of GFL631T-3

Accuracy
15%
Current Measuring Range Ac
30A To 360A
www.GEMultilin.com
Ground Fault
Current Detection Systems
Model BGFL (Relay)
Trip Currents 5 - 60 , 3 0 - 360 , or 10 0 -1 2 0 0 A
fault current on a ground ac power system. When a ground fault exceeds a pre-selected Current level and Time Delay
setting, the relay initiates a trip signal for a shunt trip disconnect device to open and clear the fault . This BGFL system
is designed to provide protection for electrical equipment , not protection for personnel.
These Class 1 Model BGFL Ground Fault Relays and Sensors are designed to form a system for detecting a ground
INPUT POWER
120 Volts ac
125 Volts dc
48 Volts dc
24 Volts dc
DEVICE
CONTACT RATING
INRUSH
10 A
1 A
4 A
8 A
CONT.
Aux. Supply Voltage
5=120V ac, 50/60Hz
4=125V dc
3=24V dc
2=48V dc
Mounting
1=Panel mount
2=Door mount
3 A
1 A
4 A
8 A
* Not Available with zone Interlocking option
HOW TO ORDER RELAYS
BGFL X X X - XXXX
“Power On” LED indicator in cover.
Meets NEC service entrance equipment standards.
Available in three basic styles, “Standard”, “Form C”, or “Zone Interlocking”
for coordination of single or multiple ground fault devices in system.
Integral test panel with Push To Test and Shunt Trip Bypass pushing for
ease in proper operational testing of the system, with or without tripping
the protective device.
Positive visual trip indicator, manual reset .
Inf initely adjustable Time Delay.
Discrete current threshold adjustment .
Panel or door mounting.
Rear terminal kit and clear plastic cover standard with door mounting.
Electromechanical relay output , positive “ON” and “OFF”.
Operates with molded case and power circuit breakers, bolted pressure
switches, fusible disconnect switches.
Internal Circuit Options
4=Isolated Internal “Form C” *
7=With Zone Interlocking
9=Without Zone Interlocking
Current Range
60=5 to 60A
360=30 to 360A
1200=100 to 1200A
OPERATING RANGE:
Trip currents of 5-60, 30-360, or 100-1200A. Time
delay from 0.10 to 1 second. (Adjustable)
INPUT POWER:
2 VA plus shunt coil requirements. Rated @ 120 Vac.
INPUT WITHSTAND:
200,000 Amperes RMS for 3 cycles, 50/60 Hz.
NOMINAL INPUT VOLTAGE:
120 Volts ac, 125 Volts dc, 24 Volts dc, 48 Volts dc.
FREQUENCY:
50/60 Hz.
AMBIENT TEMPERATURE RANGE:
-30
Only for use with GFL sensors.
Approximate weight 1.5 lbs.
o
C to +60
o
U L
®
C
110395
LR80793
7