GFL631T-3 INSTRUMENT TRANSFORMER, GFL631T-3 Datasheet - Page 27

GROUND FAULT CURENT

GFL631T-3

Manufacturer Part Number
GFL631T-3
Description
GROUND FAULT CURENT
Manufacturer
INSTRUMENT TRANSFORMER
Datasheet

Specifications of GFL631T-3

Accuracy
15%
Current Measuring Range Ac
30A To 360A
www.GEMultilin.com
systems. The LLV series is designed to meter line to line voltages and the PNV series is designed to meter phase to neutral voltages. The transducers provide
three discrete 4 to 20mA outputs that are proportional to the three phase input voltages. The input voltages scale does not meter down to zero Volts, instead it
is limited to the normal useful range of input voltages for a particular system. For example: The model PNV-120 has an input signal range from 90 to 150 V ac
and will yield an output of 4 to 20 mA dc for that range. The output is true constant current driver and is unaffected by resistance variations from 0-600 ohms
in the output loop. An external 24Vdc supply is needed to provide power for the internal solid state circuitry. The power supply input has reverse polarity
protection to prevent damage from an accidental miswire. The high accuracy solid state circuity is average responding calibrated to read RMS. This device is
an ANSI/ISO 50.1 Class L3 transmitter.
Voltage Transducers
Model LLV & PNV
APPLICATION:
NOMINAL INPUT VOLTAGES:
120V, 240V, 277V, 480V
FREQUENC Y:
ACCURACY:
AMBIENT TEMPERATURE RANGE:
Effect on accuracy: + 0.3% /
Operating: -30
Storage: -55
Power supply: 24 V dc + 10%
Max. continuous input voltage: 600V
Output: Load range: 0-600 ohms.
Load range: 4 to 20mA dc.
Ripple: <1%.
Response time: < 1.5 sec. (10% to 90%)
Approx. shipping weight 1.3 lbs.
The model LLV and PNV series of voltage transformers are expanded scale instruments which are designed to accurately measure voltages on three phase
LLV (Line-To-Line) Connection Diagram
Transfer function E
Nominal Input Voltage
Voltage Input Range
Burden (Max.)
Ripple On Output
Dielectric Test (1Min)
o
+ 0.5% Full scale.
C to +85
50/60 Hz.
o
3 Phase voltage measurement .
C to +60
o
C.
o
C
in =
o
C.
Typical 4-20 mA input to processor
Max loop resistance 600 ohms/phase
(3.75) (mA out) +75
MODEL
0.1VA at 120V
90V to 150V
1300 Volts
LINE-TO-LINE VOLTAGE
120V
LLV
LLV
PNV
ORDERING INFORMATION
XXX - XXX
(7.5) (mA out) +150
0.1VA at 265V
180V to 300V
1600 Volts
240V
LLV (Dual Range)
120
277 [ PNV Model only]
480 [ LLV [Dual Range) Model only]
TOP VIEW
TOP VIEW
(15) (mA out) +300
0.1VA at 530V
NOMINAL
360V to 600V
2200 Volts
250
It is recommended that the installation conform to NEC and any local codes.
480V
u
PNV (Phase-To-Neutral) Connection Diagram
A ac
PHASE-TO-NEUTRAL VOLTAGE
(3.75) (mA out)+75
0.1VA at 150V
90V to150V
1300 Volts
120V
Typical 4-20 mA input to processor
Max loop resistance 600 ohms/phase
142298, CANADIAN
PNV
SIDE VIEW
SIDE VIEW
(7.5) (mA out) +150
0.1VA at 300V
180V to 300V
1600 Volts
277V
C
142298
21