T186EQ BANNER ENGINEERING, T186EQ Datasheet - Page 5

no-image

T186EQ

Manufacturer Part Number
T186EQ
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Opposed Moder
Datasheets

Specifications of T186EQ

Output Current
150mA
Supply Voltage Range Dc
10V To 30V
Sensor Input
Optical
Sensing Range Max
20m
Contact Current Max
150mA
Switch Terminals
Quick Connect
Brand/series
T18
Current, Switching
150 mA
Humidity
90% (Max.) @ 50°C
Ip Rating
IP69K
Length, Cable
6.5 ft.
Light Source
Infrared LED
Material, Housing
PBT Polyester
Material, Lens
Polycarbonate⁄Acrylic
Mounting Type
Threaded
Primary Type
Photoelectric
Range, Measurement
66 mm
Response Time
3 ms (ON), 1.5 ms (OFF)
Sensing Mode
Opposed
Standards
UL Listed, CSA Recognized, CE Marked
Technology
Photoelectric
Temperature, Operating
-40 to +70 °C
Termination
4-Wire Connector
Voltage, Supply
30 VDC
Lead Free Status / Rohs Status
RoHS Exempt Product
††
sensing range may be more or less than specified, depending on the efficiency and
reflective area of the retroreflector used.
Performance based on use of a model BRT-3 retroreflector (3" diameter). Actual
Banner Engineering Corp. • Minneapolis, MN U.S.A
C
G
A
N
C
G
A
N
E
X
E
S
S
E
X
E
S
S
www.bannerengineering.com • Tel: 763.544.3164
I
I
E
X
C
E
S
S
G
A
N
I
E
X
C
E
S
S
G
A
N
1000
1000
I
1000
100
100
100
1000
10
10
10
(0.033')
(0.033')
100
1
0.01 m
1
0.01 m
1
(0.04")
10
1 mm
1
(0.33')
0.1 m
Excess Gain
Performance based on use of a 90% reflectance white test card.
(0.33')
(0.33')
0.1 m
0.1 m
10 mm
(0.4")
with BRT-3 Reflector
with BRT-3 Reflector
(3.3')
DISTANCE
DISTANCE
1 m
DISTANCE
DISTANCE
T18 Series
T18 Series
T18 Series
DC Diffuse mode
T18 Series
Non-Polarized Retro
Polarized Retro
100 mm
(3.3')
(3.3')
Opposed Mode
1 m
1 m
(4")
10 m
(33')
1000 mm
10 m
10 m
(33')
(33')
(40")
100 m
(330')
1500 mm
1000 mm
1000 mm
1500 mm
120 mm
120 mm
150 mm
100 mm
100 mm
150 mm
60 mm
40 mm
20 mm
20 mm
40 mm
60 mm
500 mm
500 mm
80 mm
40 mm
40 mm
80 mm
50 mm
50 mm
0
0
0
0
0
0
0
0
T18 Series
DC Diffuse Mode
T18 Series
Non-Polarized Retro
T18 Series
Polarized Retro
T18 Series
Opposed Mode
125 mm
(5")
0.5 m
(1.6')
0.5 m
(1.6')
Beam Pattern
(16')
5 m
with BRT-3 Reflector
with BRT-3 Reflector
250 mm
(10")
1.0 m
1.0 m
(3.2')
(3.2')
DISTANCE
10 m
(32')
DISTANCE
DISTANCE
DISTANCE
375 mm
(15")
1.5 m
1.5 m
(4.8')
(4.8')
15 m
(49')
Performance Curves
500 mm
(20")
2.0 m
(6.4')
2.0 m
(6.4')
20 m
(66')
T18 Sensors — dc-Voltage Series
625 mm
(25")
2.5 m
2.5 m
(8.0')
(8.0')
25 m
(82')
2.4"
1.6"
0.8"
0
0.8"
1.6"
2.4"
4.7"
3.2"
1.6"
0
1.6"
3.2"
4.7"
6"
4"
2"
0
2"
4"
6"
60"
40"
20"
0
20"
40"
60"
Focus and spot sizes are typical.
C
G
A
N
E
X
E
S
S
E
X
C
E
S
S
G
A
N
E
X
C
E
S
S
G
A
N
I
I
I
1000
1000
1000
100
100
100
10
10
10
(0.004")
0.1 mm
(0.004")
(0.004")
1
1
0.1 mm
1
0.1 mm
Performance based on use of a 90% reflectance white test card.
(0.04")
(0.04")
(0.04")
1 mm
1 mm
1 mm
DISTANCE
DISTANCE
DISTANCE
T18 Series
T18 Series
T18 Series
Fixed-field mode
with 100 mm far
Fixed-field mode
Fixed-field mode
10 mm
with 25 mm far
with 50 mm far
10 mm
10 mm
(0.4")
(0.4")
(0.4")
limit cutoff
limit cutoff
limit cutoff
Excess Gain
100 mm
100 mm
100 mm
(4")
(4")
(4")
Ø 10 mm spot size @ 8 mm focus
Ø 10 mm spot size @ 25 mm cutoff
† Using 18% gray test card: Cutoff
† Using 6% black test card: Cutoff
Ø 10 mm spot size @ 10 mm focus
Ø 10 mm spot size @ 50 mm cutoff
† Using 18% gray test card: Cutoff
† Using 6% black test card: Cutoff
Ø 10 mm spot size @ 20 mm focus
Ø 10 mm spot size @ 100 mm cutoff
† Using 18% gray test card: Cutoff
† Using 6% black test card: Cutoff
distance will be 95% of value shown.
distance will be 90% of value shown.
distance will be 90% of value shown.
distance will be 85% of value shown.
distance will be 85% of value shown.
distance will be 75% of value shown.
P/N 121526 rev. A
5