S183E BANNER ENGINEERING, S183E Datasheet - Page 41

Photoelectric Sensor

S183E

Manufacturer Part Number
S183E
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Opposed Moder
Datasheets

Specifications of S183E

Output Current
150mA
Supply Voltage Range Dc
10V To 30V
Contact Current Max
300mA
Switch Terminals
Cable
Sensor Housing
Barrel
Sensor Input
Optical
Sensing Range Max
20m
Sensing Mode
Opposed
Brand/series
S18
Current, Switching
300 mA
Humidity
90% @ 50 °C (Non-Condensing)
Ip Rating
IP69K
Length, Cable
6.5 ft.
Material, Housing
PBT Polyester
Material, Lens
Polycarbonate⁄Acrylic
Output
SPST
Primary Type
Photoelectric
Range, Measurement
66 mm
Response Time
16 ms (ON), 8 ms (OFF)
Standards
CE Mark, CSA Certified, UL Listed
Technology
Photoelectric
Temperature, Operating
-40 to +70 °C
Termination
Cable
Vibration
10 to 60 Hz (Max.)
Voltage, Supply
250 VAC
Lead Free Status / Rohs Status
RoHS Exempt Product
Supply Voltage and Current
Supply Protection Circuitry
Output Configuration
Output Rating
Output Protection Circuitry
Output Response Time
Repeatability
Indicators
Construction
Environmental Rating
Connections
Operating Conditions
Vibration and
Mechanical Shock
Certifications
Hookup Diagrams
10 to 30V dc (10% max. ripple); Supply current (exclusive of load current):
Opposed Mode Emitters: 25 mA
Polarized Retroreflective: 30 mA
Protected against reverse polarity and transient voltages
Solid-state complementary (SPDT) dc switch; NPN (current sinking) or PNP (current sourcing), depending on model.
The Dark Operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon
hookup to the power supply.
150 mA max. (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA
Off-state leakage current: less than 1 mA at 30V dc
On-state saturation voltage: less than 1V at 10 mA dc; <1.5V at 150 mA dc
Protected against false pulse on power-up and continuous overload or short circuit of outputs
Opposed: 3 milliseconds ON, 1.5 milliseconds OFF; Polarized Retroreflective and
Fixed-field: 3 milliseconds ON/OFF
NOTE: 100 millisecond delay on power-up; outputs do not conduct during this time
Opposed: 375 microseconds; Polarized Retroreflective and Fixed-field: 750 microseconds. Repeatability and
response are independent of signal strength.
Two LEDs: Green and Yellow
Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; come with one jam nut.
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. See page 380.
Temperature: -40° to +70° C
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double
amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for
non-operation)
Emitters: DC03 (p. 476)
Green ON steady: power to sensor is ON
Green flashing: output is overloaded (dc models only)
Yellow ON steady: Light Operate (LO) output is energized
Yellow flashing: excess gain marginal (1-1.5x) in light condition, LO output is energized
Q25 DC Specifications
R
NPN Models: DC07 (p. 477)
Relative humidity: 90% at 50° C (non-condensing)
More information online at
Opposed Mode Receivers: 20 mA
Fixed-field: 35 mA
PNP Models: DC08 (p. 477)
bannerengineering.com
Compact Sensors
Q25 Series
105

Related parts for S183E