Photoelectric Sensor

S18SN6FF50Q

Manufacturer Part NumberS18SN6FF50Q
DescriptionPhotoelectric Sensor
ManufacturerBANNER ENGINEERING
TypeFixed Field
S18SN6FF50Q datasheets
 


Specifications of S18SN6FF50Q

Output Current150mASensor OutputNPN
Supply Voltage Range Dc10V To 30VSensing Range Max25mm
Leaded Process CompatibleNoPeak Reflow Compatible (260 C)No
Sensor InputLaserPrimary TypePhotoelectric
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
Page 1/7

Download datasheet (2Mb)Embed
Next
Sensing Mode
Opposed
Retroreflective
Polarized
P
Retroreflective
Diffuse
Fixed-Field
* Standard 2 m (6.5') cable models are listed.
• 9 m (30') cable: add suffix “W/30” (e.g., S186E W/30).
• 4-pin Euro-style QD models: add suffix “Q” (e.g., S186EQ). A model with a QD connector requires a mating cable. (See page 7.)
Use polarized models when shiny objects will be sensed.
WARNING . . .
Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.
Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for
personnel protection.
Printed in USA
S18 Sensors – dc-Voltage Series
Self-contained dc-operated sensors
®
• Featuring EZ-BEAM
technology for reliable sensing without the need for
adjustments
• Completely epoxy-encapsulated to provide superior durability, designed to meet
rigorous IP69K standards for use in 1200 psi washdowns
• Innovative dual-indicator system for simple sensor performance monitoring
• Advanced diagnostics to warn of marginal sensing conditions or output overload
• 10 to 30V dc; choose SPDT (complementary) NPN or PNP outputs
(150 mA max. ea.)
Models
Range
20 m (66')
2 m (79")
100 mm (4")
300 mm (12")
25 mm (1") cutoff
50 mm (2") cutoff
100 mm (4") cutoff
01/05
Features
LED
Output
Model*
S186E
NPN
S18SN6R
Infrared
PNP
S18SP6R
950 nm
NPN
S18SN6L
PNP
S18SP6L
NPN
S18SN6LP
Visible Red
680 nm
PNP
S18SP6LP
NPN
S18SN6D
PNP
S18SP6D
NPN
S18SN6DL
PNP
S18SP6DL
NPN
S18SN6FF25
Infrared
880 nm
PNP
S18SP6FF25
NPN
S18SN6FF50
PNP
S18SP6FF50
NPN
S18SN6FF100
PNP
S18SP6FF100
P/N 121522

S18SN6FF50Q Summary of contents

  • Page 1

    Sensing Mode Opposed Retroreflective Polarized P Retroreflective Diffuse Fixed-Field * Standard 2 m (6.5') cable models are listed. • (30') cable: add suffix “W/30” (e.g., S186E W/30). • 4-pin Euro-style QD models: add suffix “Q” (e.g., S186EQ). A ...

  • Page 2

    ... R2 Figure 1. Fixed-field concept As a general rule, the most reliable sensing of an object approaching from the side occurs when the line of approach is parallel to the sensing axis. Figure 2. Fixed-field sensing axis Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 or ...

  • Page 3

    ... Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 S18 Sensors – dc-Voltage Series Color Sensitivity The effects of object reflectivity on cutoff distance, though small, may be important for some applications expected that at any given cutoff setting, the actual cutoff distance for lower reflectance targets will be slightly shorter than for higher reflectance targets (see Figure-of-Merit information on page 5) ...

  • Page 4

    ... Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation) Certifications 4 P/N 121522 Specifications wired as a normally open marginal signal alarm output, depending upon hookup to power supply Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 ...

  • Page 5

    ... Performance based on use of a model BRT-3 retroreflector (3" diameter). Actual sensing range may be more or less than specified, depending on the efficiency and reflective area of the retroreflector used. Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 S18 Sensors – dc-Voltage Series ...

  • Page 6

    ... NOTE: QD hookups are functionally identical. QD Models Yellow LED Green LED Jam Nuts (2 Provided Thread 37.0 mm 78.0 mm* (1.46") (3.07") PNP (Sourcing) Outputs Standard Hookup 30V dc bu – bk Load wh Load Alarm Hookup bn – 30V Load wh Alarm Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 ...

  • Page 7

    ... Right-angle MQDC-430RA WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • ...