S18SN6FF50Q BANNER ENGINEERING, S18SN6FF50Q Datasheet - Page 16

Photoelectric Sensor

S18SN6FF50Q

Manufacturer Part Number
S18SN6FF50Q
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Fixed Fieldr
Datasheets

Specifications of S18SN6FF50Q

Output Current
150mA
Sensor Output
NPN
Supply Voltage Range Dc
10V To 30V
Sensing Range Max
25mm
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Sensor Input
Laser
Primary Type
Photoelectric
80
Compact Sensors
MINI-BEAM
Supply Voltage and Current
Supply Protection Circuitry
Output Configuration
Output Rating
Output Protection Circuitry
Output Response Time
Repeatability
Adjustments
Indicators
Construction
Environmental Rating
Connections
Operating Conditions
Application Notes
Certifications
Hookup Diagrams
More information online at
®
Series
24 to 240V ac (50/60 Hz), 250V ac max
Protected against transient voltages
SPST SCR solid-state relay (light/dark operate selectable); 2-wire hookup
Min. load current 5 mA; max. steady-state load capability 300 mA to 50° C ambient
100 mA to 70° C ambient
Inrush capability: 3 amps for 1 second (non repetitive); 10 amps for 1 cycle (non repetitive)
Off-state leakage current: less than 1.7 mA rms
On-state voltage drop: ≤ 5 volts at 300 mA load, ≤ 10 volts at 15 mA load
Protected against false pulse on power-up
Opposed Mode: 2 milliseconds on and 1 millisecond off;
Non-Polarized and Polarized Retroreflective, Convergent, Plastic Fiber Optic: 4 milliseconds on and off;
Diffuse and Glass Fiber Optic: 8 milliseconds on and off
“OFF” response time specification does not include load response of up to ½ ac cycle (8.3 milliseconds).
Response time specification of load should be considered when important.
NOTE: 300 millisecond delay on power-up.
Opposed: 0.3 milliseconds
Non-Polarized and Polarized Retroreflective, and Convergent and Plastic Fiber Optic: 1.3 milliseconds
Diffuse and Glass Fiber Optics: 2.6 milliseconds
Response time and repeatability specifications are independent of signal strength.
LIGHT/DARK OPERATE select switch, and 15-turn slotted brass screw GAIN (sensitivity) adjustment potentiometer
(clutched at both ends of travel). Both controls are located on rear panel of sensor and protected by a gasketed,
clear acrylic cover.
Red indicator LED on rear of sensor is “ON” when the load is energized
Reinforced thermoplastic polyester housing, totally encapsulated, o-ring sealing, acrylic lenses, and stainless steel screws
Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 6, 12, and 13; IEC IP67
PVC-jacketed 2-conductor 2 m or 9 m cables, or 3-pin micro-style quick-disconnect (QD) fitting are available. QD
cables are ordered separately. See page 386.
Temperature: -20° to +70° C
i)
ii) Low voltage use requires careful analysis of the load to determine if the leakage current or on-state voltage of
iii) The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in
Cabled Emitters: AC03 (p. 484)
QD Emitters: AC04 (p. 484)
bannerengineering.com
Overload conditions can destroy ac MINI-BEAM sensors. Directly wiring sensor without load series across hot
and neutral will damage sensor (except emitter models).
the sensor will interfere with proper operation of the load.
series or parallel with mechanical switch contacts.
MINI-BEAM
®
AC Specifications
Relative humidity: 90% at 50° C (non-condensing)
All Other QD Models: AC02 (p. 484)
All Other Cabled Models: AC01 (p. 484)

Related parts for S18SN6FF50Q