S18SN6FF50Q BANNER ENGINEERING, S18SN6FF50Q Datasheet - Page 38

Photoelectric Sensor

S18SN6FF50Q

Manufacturer Part Number
S18SN6FF50Q
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Fixed Fieldr
Datasheets

Specifications of S18SN6FF50Q

Output Current
150mA
Sensor Output
NPN
Supply Voltage Range Dc
10V To 30V
Sensing Range Max
25mm
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Sensor Input
Laser
Primary Type
Photoelectric
102
T18 Series
Compact Sensors
*
** For 9 m cable, add suffix W/30 to the 2 m model number (example, T18AW3FF25 W/30). A model with a QD requires a mating cable (see page 386).
T18, 20-250V ac
T18AW3FF25
T18AW3FF25Q1
T18RW3FF25
T18RW3FF25Q1
T18AW3FF50
T18AW3FF50Q1
T18RW3FF50
T18RW3FF50Q1
T18AW3FF100
T18AW3FF100Q1
T18RW3FF100
T18RW3FF100Q1
Supply Voltage and Current
Supply Protection Circuitry
Output Configuration
Output Rating
Output Protection Circuitry
Output Response Time
Repeatability
Adjustments
Indicators
Construction
Environmental Rating
Connections
Operating Conditions
Vibration and
Mechanical Shock
Certifications
Hookup Diagrams
More information online at
Models
Infrared LED
FIXED-FIELD
Mode/LED*
Sensing
(cont’d)
20 to 250V ac (50/60 Hz). Average current 20 mA. Peak current: 200 mA at 20V ac, 500 mA at 120V ac, 750 mA at 250V ac
Protected against transient voltages
SPST solid-state ac switch; three-wire hookup; Light Operate (LO) or Dark Operate (DO), depending on model.
Light operate: Output conducts when the sensor sees its own (or the emitter’s) modulated light
Dark operate: Output conducts when sensor sees dark
300 mA max. (continuous) Fixed-field models: derate 5 mA/° C above +50° C;
Inrush capability: 1 amp for 20 milliseconds, non-repetitive
Off-state leakage current: less than 100 mA
On-state voltage drop: 3V at 300 mA ac; 2V at 15 mA ac
Protected against false pulse on power-up
Opposed Mode: 16 milliseconds ON, 8 milliseconds OFF
Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field & Diffuse: 16 milliseconds ON/OFF
NOTE: 100 millisecond delay on power-up
Opposed Mode: 2 ms; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field, and
Diffuse: 4 milliseconds Repeatability and response are independent of signal strength.
T18 Series infrared non-polarized retroreflective and diffuse mode models (only) have a single-turn rear-panel
SENSITIVITY control for adjustment of system gain (turn clockwise to increase)
Two LEDs: Green and Yellow
Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; T18 models come with one jam nut.
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
2 m or 9 m attached cable, or 4 pin Micro-style quick-disconnect fitting. QD cables are ordered separately. See
page 386.
Temperature: -40° to +70° C
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max, double
amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for
non-operation)
Cabled Emitters: AC03 (p. 484)
QD Emitters: AC07 (p. 485)
bannerengineering.com
Green ON steady: power to sensor is ON
Yellow ON steady: sensor sees light
Yellow flashing: excess gain marginal (1-1.5x) in light condition
0 - 100 mm
0 - 25 mm
0 - 50 mm
Range
Cutoff
Cutoff
Cutoff
T18 AC Specifications
R
4-Pin Micro QD
4-Pin Micro QD
4-Pin Micro QD
4-Pin Micro QD
4-Pin Micro QD
4-Pin Micro QD
Cable**
Relative humidity: 90% at 50° C (non-condensing)
2 m
2 m
2 m
2 m
2 m
2 m
Other cabled Models: AC05 (p. 485)
Other QD Models: AC06 (p. 485)
Output
Type
DO
DO
DO
LO
LO
LO
Excess
EGCF-12
EGCF-13
EGCF-14
(p. 441)
(p. 441)
(p. 441)
Gain
Pattern
Beam
Sheet
32994
Data
Download