T186E

Manufacturer Part NumberT186E
DescriptionPhotoelectric Sensor
ManufacturerBANNER ENGINEERING
TypeOpposed Mode
T186E datasheets
 

Specifications of T186E

Output Current150mASupply Voltage Range Dc10V To 30V
Sensor InputOpticalSensing Range Max20m
Contact Current Max150mASwitch TerminalsCable
Sensing ModeOpposedBrand/seriesT18
Current, Switching150 mAHumidity90% @ 50 °C (Non-Condensing)
Ip RatingIP69KLength, Cable6.5 ft.
Material, HousingPBT PolyesterMaterial, LensPolycarbonate⁄Acrylic
Mounting TypeThreadedPrimary TypePhotoelectric
Range, Measurement66 mmResponse Time3 ms (ON), 1.5 ms (OFF)
StandardsCE Mark, CSA Certified, UL ListedTechnologyPhotoelectric
Temperature, Operating-40 to +70 °CTerminationCable
Vibration10 to 60 Hz (Max.)Voltage, Supply30 VDC
Accessories AvailableCordsets, Brackets and ReflectorsLead Free Status / Rohs StatusRoHS Exempt Product
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
Page 1/6

Download datasheet (2Mb)Embed
Next
Sensing Mode
Opposed
OPPOSED
Retroreflective
with Gain control
RETRO
Polarized
P
Retroreflective
POLAR RETRO
Diffuse
with Gain control
DIFFUSE
Fixed-Field
FIXED-FIELD
*
Standard 2 m (6.5') cable models are listed.
• 9 m (30') cable: add suffix “W/30” (e.g., T186E W/30).
• 4-pin Euro-style QD models: add suffix “Q” (e.g., T186EQ). A model with a QD connector requires a mating cable. (See page 7.)
**
Use polarized models when shiny objects will be sensed.
WARNING . . .
Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A
sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner
Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
Printed in USA
T18 Sensors — DC-Voltage Series
Self-Contained DC-Operated Sensors
Featuring EZ-BEAM® technology to provide reliable sensing without the need for adjustments
(most models)
“T” style plastic housing with 18 mm threaded lens mount
Models available in opposed, retroreflective, diffuse, and fixed-field modes
Completely epoxy-encapsulated to provide superior durability, even in harsh sensing
environments rated to IP69K
Innovative dual-indicator system takes the guesswork out of sensor performance monitoring
Advanced diagnostics to warn of marginal sensing conditions or output overload
10 to 30V dc; choose SPDT (complementary) NPN or PNP outputs (150 mA max. ea.)
Models
Model*
T186E
T18SN6R
T18SP6R
T18SN6L
T18SP6L
T18SN6LP
T18SP6LP
T18SN6D
T18SP6D
T18SN6FF25
T18SP6FF25
T18SN6FF50
T18SP6FF50
T18SN6FF100
T18SP6FF100
02/08
Features
Range
LED
20 m (66')
Infrared
950 nm
2 m (79")**
Visible Red
680 nm
500 mm (20")
25 mm (1") cutoff
Infrared
880 nm
50 mm (2") cutoff
100 mm (4") cutoff
P/N 121526 rev. A
Output
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP

T186E Summary of contents

  • Page 1

    ... Standard 2 m (6.5') cable models are listed. • (30') cable: add suffix “W/30” (e.g., T186E W/30). • 4-pin Euro-style QD models: add suffix “Q” (e.g., T186EQ). A model with a QD connector requires a mating cable. (See page 7.) ** Use polarized models when shiny objects will be sensed. ...

  • Page 2

    ... Figure 1. Fixed-field concept Sensing general rule, the most reliable sensing of an object approaching from the side occurs when the line of approach is parallel to the sensing axis. Figure 2. Fixed-field sensing axis Banner Engineering Corp. • Minneapolis, MN U.S.A www.bannerengineering.com • Tel: 763.544.3164 Object B or Background Axis ...

  • Page 3

    ... Banner Engineering Corp. • Minneapolis, MN U.S.A www.bannerengineering.com • Tel: 763.544.3164 T18 Sensors — dc-Voltage Series The object then reflects the R1 and R2 fields equally, resulting in no false triggering. A better solution, if possible, may be to reposition the object or the sensor. Color Sensitivity The effects of object reflectivity on cutoff distance, though small, may be important for some applications ...

  • Page 4

    ... Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation) Certifications 4 P/N 121526 rev. A Specifications normally open marginal signal alarm output, depending upon hookup to power supply Banner Engineering Corp. • Minneapolis, MN U.S.A www.bannerengineering.com • Tel: 763.544.3164 ...

  • Page 5

    ... Performance based on use of a model BRT-3 retroreflector (3" diameter). Actual sensing range may be more or less than specified, depending on the efficiency and reflective area of the retroreflector used. Banner Engineering Corp. • Minneapolis, MN U.S.A www.bannerengineering.com • Tel: 763.544.3164 T18 Sensors — dc-Voltage Series ...

  • Page 6

    ... This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 121526 rev. A Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com Dimensions Sensitivity (Gain) Control 41.5 mm (1.64" ...