P11100100048703 BARBER - COLMAN, P11100100048703 Datasheet

Thermocouple

P11100100048703

Manufacturer Part Number
P11100100048703
Description
Thermocouple
Manufacturer
BARBER - COLMAN
Datasheet

Specifications of P11100100048703

Lead Length
48"
Thermocouple Type
J
Terminal Type
Wire Leaded
Probe Length
48
Output Type
Voltage
Temperature Max
93°C
Mounting Type
1/4" Screw Lug
Features
Stainless Steel Overbraid
Lead Free Status / RoHS Status
na
Plastics Industry Sensors
HA136712
Page 2-1

Related parts for P11100100048703

P11100100048703 Summary of contents

Page 1

Plastics Industry Sensors HA136712 Page 2-1 ...

Page 2

... Or, if the sensor is an RTD, the tip is potted in the hole in the bolt. Ring type and lug type sensors measure surface temperature – such as a barrel or a mold. The sensor leads are joined at the ring or lug (hot junction). The sensor attaches to a threaded stud on the workpiece and must be secured with a nut ...

Page 3

... The threaded bushing mounts directly into a tapped hole in the workpiece. Element The thermocouple element is defined by its calibration (type), wire size (gauge), construction (solid, strand, insulation). The resistance temperature detector (RTD) is defined by its resistance coefficient. Element Protection Element protection is defined by its construction: rigid tube, flexible armor (or flexible tube), stainless steel overbraid, spring, or insulation only. Rigid length is identified as dimension " ...

Page 4

... The fitting is shipped with both a nylon and brass ferrule. Nylon permits readjustment, but should not be exposed to temperature over 250°F. The brass ferrule cannot be adjusted after it is set suitable for temperatures up to 900°F. ...

Page 5

... Round the adapter length up to the nearest 1/8". Pipe Clamp Adapter This adapter can be used with thermocouples with bayonet lock to measure tube or pipe surface temperatures. The thermocouple is in direct contact with the pipe. The adapter is available with the "L" dimension in 1/2" increments beginning with 1-1/2" ...

Page 6

... This section of the book is devoted to sensors designed primarily for application in the plastics manufacturing industry. Two types of sensors are listed: thermocouples and resistance temperature detectors. This section tells you how to identify the specifications of a thermocouple from the model number. ...

Page 7

... Model Number Breakdown Analyzing a Model Number (continued) Fields 2 and 3 Element Two wires of dissimilar alloys joined at the tip. When the ends are exposed to a temperature gradient, and electromotive force (EMF) is generated. The EMF is very small, amounting to microvolts per degree. Field 4 Element Configuration This field indicates either single or dual element in a straight, 45° ...

Page 8

Ordering Information Illustrations on the following pages list wire most commonly used in specific thermocouples (Fields the part number); however, any wire from the following table can be used. Standard and special limits (tolerances) are defined in ...

Page 9

Ordering Information (continued) Component Compatibility The number of elements in a thermocouple is constrained by wire size, probe diameter, and lead protection. The table below shows the compatibility of these components Table 2. Compatibility * Dual only for code 34 ...

Page 10

Varidepth Introduction Features Ordering Information 3/16" P011 Y P021 (±2") P121 P601 P051 P621 P014 P024 P124 P604 L (6" standard) 2-1/2" (±1/4") Page 2-10 Varidepth T/C, Armor ® Adjustable Depth Immersion Thermocouple in Armor Clad Flexible Tube The Varidepth ...

Page 11

Varidepth T/C, Armor Ordering Information (continued) Field 7. COLD END TERMINATION Hollow pin quick disconnect plug(s), Type J only D - Hollow pin quick disconnect plug(s) ...

Page 12

... Varidepth in Armor Clad Flexible Tube Introduction The Varidepth resistance temperature detector adjusts to many depths eliminating the need to stock a variety of fixed immersion sensors. Compression of the flexible tube provides locking force that keeps the probe tip tight against the bottom of the adapter well. ...

Page 13

... YYY - Actual length in whole inches (minimum 018) Field 13. RESERVED Fields 14, 15. LEAD LENGTH (DIMENSION "L")* 00 - 6" Actual length in feet 99 - Longer than 98 feet *Total assembly length over 4 feet introduces an offset in sensed temperature of L approximately 1-1/4°F per 10 feet over 4 feet. (6" standard) 2-1/2" (±1/4") ...

Page 14

Varidepth T/C, Spring Style Varidepth Introduction Features Brass Tip Ceramic Insulator Metal Adapter Optional Junction (Code 61) 3/16" P111 P071 P131 P151 P081 P241 Y P114 P074 P134 P154 P084 P244 2-1/2" std. Page 2-14 ® Adjustable Depth Immersion Thermocouple ...

Page 15

Varidepth T/C, Spring Style Ordering Information (continued) Field 7. COLD END TERMINATION Fields 8, 9. RESERVED Fields 10, 11, 12. FLEXIBLE LENGTH (DIMENSION "Y") ...

Page 16

... Fields 10, 11, 12. FLEXIBLE LENGTH (DIMENSION “Y”)* Complete these Fields to determine length for Field 3 YYY - Actual length in whole inches (minimum 018") *Total assembly length over 4 feet introduces an offset in sensed temperature of approximately 1-1/4°F per 10 feet over 4 feet. Field 13. SPRING AND LOCKCAP B - 12" ...

Page 17

For a Complete Selection of Accessories and Component Parts, See Our Listing Under "Accessories" Beginning on Page 2-40 54-00198 Brass or Nylon Ferrule Nickel Plated Brass Compression Fitting Brass or Nylon Ferrule 3/16" o.d. Stainless Steel Tube 2-5/16" 1/4" 7/8" ...

Page 18

... Closed end tubes are silver soldered for Types J, T and E; and welded for Type K. Bayonet thermocouples are generally rated for service to 900°F under dry conditions; temperature rating does not apply to cold end terminations. • Locking Cap/Spring for Quick and Easy Attachment/Detachment • ...

Page 19

Fixed T/C, Bayonet Field 7. COLD END TERMINATION 0 - 3/16" ±1 Hollow pin quick disconnect plug(s), Type J only D - Hollow pin quick disconnect plug(s) ...

Page 20

Fixed Depth Immersion Thermistor with Bayonet Lock Adjustable Depth Immersion Thermistor with Compression Fitting Introduction Ordering Information Z 3/16" P211 P212 P213 1-7/8" P221 P222 P223 3/16" P231 P232 P233 1-7/8" 3/16" P411 P412 P413 Z ±1/8" P421 P422 P423 ...

Page 21

Ordering Information (continued) Fields 8, 9. RIGID LENGTH (DIMENSION "X")(COMPRESSION FITTING ONLY) X ±1/8" 1-7/8" 90° ±1/4 Fields 10, 11, 12. FLEXIBLE LENGTH (DIMENSION "Y") 000 - None 5/16" R for 3/16" O.D. YYY - Enter ...

Page 22

... Fixed Depth Immersion RTD with Bayonet Lock Bayonet resistance temperature detectors have a compressible spring and locking cap for quick insertion and detachment. They are available with no protection tube ( insulation only), armor clad flexible tube, or stainless steel overbraid. All are light weight for easy connection to an instrument or a distant junction box ...

Page 23

... Not listed; specify on order *Total assembly length over 4 feet introduces an offset in sensed temperature of approximately 1-1/4°F per 10 feet over 4 feet. HA136712 Determine length by completing Fields 10, 11, and 12. 2-1/2" split leads, ends stripped 2-1/2" split leads, spade lugs 2-1/2" ...

Page 24

Adjustable T/C, Bayonet or Compression Adjustable Depth Immersion Thermocouple with Bayonet Lock or Compression Attachment Introduction Features Ordering Information 1/8" P011 P012 P013 1-5/8" X P014 (±1/8") P015 P016 P071 P072 P073 1-3/16" P074 Minimum P075 P076 P111 P112 7/16" ...

Page 25

Adjustable T/C, Bayonet or Compression Fields 5, 6. JUNCTION STYLE, PROBE O.D., LEAD PROTECTION 1/8" or 3/16" Closed end, grounded 23 - Closed end, grounded 30 - Open end, grounded 31 - Closed end, grounded ...

Page 26

... Fixed or Adjustable Depth Immersion Thermocouple wire is duplex insulated, temperature rated to 900°F except Type T which is limited to 700°F. These temperatures do not apply to cold end termination. Standard junction style is closed and grounded. Type K has a welded tip; others are silver soldered tipped probes for faster response. ...

Page 27

Rigid T/C, Fixed or Adjustable Fields 5, 6. JUNCTION STYLE, PROBE O.D., LEAD PROTECTION Check compatibility Table 2 at beginning of this section Closed end, grounded 30 - Open end, grounded 31 - Closed end, grounded 34 - ...

Page 28

... Model No Field No Fields 1, 2. BASE MODEL P5 - 0.00391 / /°C Resistance Temperature Detector P7 - 0.00385 / /°C Resistance Temperature Detector P8 - 0.00385 / /°C RTD and Type J Thermocouple Field 3. ELEMENT Accuracy (at 300°F) Temp Rating 1 - 0.25 0.10% ...

Page 29

... For other lengths, consult factory. Fields 8, 9. RIGID LENGTH (DIMENSION "X")* XX - Length in whole inches (02" minimum) *Total assembly length over 4 feet introduces an offset in sensed temperature of approximately 1-1/4°F per 10 feet over 4 feet. Fields 10, 11, 12. FLEXIBLE LENGTH (DIMENSION “Y”)* 000 - None. Used only with Field 7, code ...

Page 30

... Ring, Lug T/C Ring Type and Lug Type Thermocouples These thermocouples measure surface temperature – such as a barrel or mold. The ring or lug is placed over a threaded stud and secured with a nut. A ring or lug thermocouple is often connected in parallel with another thermocouple to control at average temperature between barrel surface and some point inside the barrel ...

Page 31

Ordering Information (continued) Field 7. COLD END TERMINATION Hollow pin quick disconnect plug(s), Type J only D - Hollow pin quick disconnect plug(s) with jack(s), Type ...

Page 32

... The nozzle melt thermocouple is designed for injection molders. This stainless steel thermocouple fits on the nozzle of an injection molding machine and senses the actual temperature of the plastic just before it is injected into the mold. This allows accurate control of the nozzle. Direct contact is the most reliable way to measure the melt temperature. ...

Page 33

Nozzle Melt T/C Ordering Information (continued) T (±1/32") Fields 5, 6. JUNCTION STYLE, PROBE O.D., LEAD PROTECTION Fields 2,3, Code 15 only 3/8-24 15/16" Closed end, grounded Thread 23 - Closed end, grounded Fields 2, 3, Code 16 ...

Page 34

Non-Immersion Nozzle T/C Introduction Ordering Information 1/4-28 3/8" Thread P021 P131 P151 3/16" P261 Y (±2") U.S.A. U.S.A. ILL. ILL. ARK, PARK, P LOVES LOVES CO. BARBER-COLMAN CO. BARBER-COLMAN Page 2-34 Non-Immersion Nozzle Thermocouple The non-immersion nozzle melt single element ...

Page 35

... Tolerances for two lead probes longer than 48" are increased .03 ohm for each 12" over 48" length: Temperature range: -148° to 932°F (-100 to 500°C), reduced to 350°F (176°C) for plug connector. Insulation resistance: 100 megohms minimum at 100 Vdc. Leads to case. ...

Page 36

... Fixed Depth Immersion Melt bolt thermocouples are used on extruders and injection molding machines. The immersed tip provides direct melt temperature measurement. Two styles are available: • MgO insulated wire in a full length, rigid stainless steel probe • Fiberglass insulated wire in a rigid stainless steel probe with a flexible, armor clad protection tube Standard bolt lengths are 3" ...

Page 37

Melt Bolt T/C, Fixed Ordering Information (continued) Field 7. COLD END TERMINATION 0 - 2-1/2" split leads, ends stripped 2-1/2" split leads, spade lugs 2-1/2" split leads, spade lugs, 1/2" NPS box connector with lock nut* ...

Page 38

... Tolerances for two lead probes longer than 48" are increased .03 ohm for each 12" over 48" length: Temperature range: -148° to 932°F (-100 to 500°C), reduced to 350°F (176°C) for plug connector. Insulation resistance: 100 megohms minimum at 100 Vdc; leads to case. ...

Page 39

... Retractable Melt Bolt Thermocouple Introduction The retractable melt bolt thermocouple measures melt stream temperature under working conditions. It can be installed wherever standard melt bolt thermocouples are used. Bolt lengths of 3", 5" and 7" are available. A ceramic insulator in the bolt tip reduces conduction from the barrel ...

Page 40

... The fitting is shipped with both a nylon and brass ferrule. Nylon permits readjustment, but should not be exposed to temperature over 250°F. The brass ferrule cannot be adjusted after it is set suitable for temperatues up to 900°F. ...

Page 41

Stainless Steel Flexible Armor Cable Assemblies 0.188" i.d., 0.266" o.d. Weight 0.6 ounce per foot. 54-00198-000-0-00 brass eyelet crimped on termination end. Part Number A-09830-000-0-12 A-09830-000-0-24 A-09830-000-0-36 A-09830-000-0-48 A-09830-000-0-60 A-09830-000-0-72 A-09830-000-0-84 A-09830-000-0-96 A-09830-000-1-20 A-09830-000-1-44 Brass Eyelet To be inserted in ...

Page 42

Bayonet Lock Adapters To determine the nominal adapter length, proceed as follows: Adapters with 1/8 NPT: "Z" dimension minus hole depth minus 3/8". Adapters with 3/8-24 thread: "Z" dimension mi- nus hole depth minus 1/4". Round the adapter up to ...

Page 43

Adapters with Slot – Custom Lengths (Continued) (Minimum ten adapters per order) Part Number A-11356-000-0-24 A-11355-000-0-26 A-11356-000-0-26 A-11355-000-0-28 A-11356-000-0-28 A-11355-000-0-30 A-11356-000-0-30 A-11355-000-0-32 A-11356-000-0-32 A-11355-000-0-34 A-11356-000-0-34 A-11355-000-0-36 A-11356-000-0-36 A-11355-000-0-38 A-11356-000-0-38 A-11355-000-0-40 A-11356-000-0-40 A-11355-000-0-42 A-11356-000-0-42 A-11355-000-0-44 A-11356-000-0-44 A-11355-000-0-46 A-11356-000-0-46 A-11355-000-0-48 A-11356-000-0-48 A-11355-000-0-50 ...

Page 44

... A-11356-000-0-90 A-11355-000-0-92 A-11356-000-0-92 A-11355-000-0-94 A-11356-000-0-94 A-11355-000-0-96 A-11356-000-0-96 Adapter, Pipe Clamp This adapter can be used with thermocouples with bayonet lock to measure tube or pipe surface temperatures. The thermocouple is in direct contact with pipe. Part Number A-05915-100-0-00 "A" A-05915-200-0-00 A-05915-300-0-00 "L" A-05915-400-0-00 A-05915-500-0-00 A-05915-600-0-00 ...