QS18UPAE BANNER ENGINEERING, QS18UPAE Datasheet

Ultrasonic Sensor

QS18UPAE

Manufacturer Part Number
QS18UPAE
Description
Ultrasonic Sensor
Manufacturer
BANNER ENGINEERING
Type
Ultrasonicr
Datasheets

Specifications of QS18UPAE

Sensing Range Min
50mm
Sensing Range Max
500mm
Switching Frequency
300kHz
Operating Temperature Range
-20°C To +60°C
Supply Voltage
30VDC
Sensor Terminals
Cable
Control Output Type
PNP
Frequency
300kHz
Body Style
Miniature
Brand/series
World-Beam®
Current, Switching
100 mA
Function
Proximity
Ip Rating
IP68
Mounting Type
Threaded
Output
PNP, SPST
Primary Type
Proximity
Range, Measurement
500 mm
Technology
Ultrasonic
Termination
4-Wire Cable
Voltage, Supply
30 VDC
Accessories Available
Cordsets, Brackets and Wave Guide
Sensor Output
PNP
* Only standard 2 m (6.5') cable models are listed. For 9 m (30') shielded cable, add suffix “W/30” to the model number (e.g., QS18UNA W/30).
QD models:
• For 4-pin integral Euro-style QD, add suffix “Q8” (e.g., QS18UNAQ8).
• For 4-pin integral Pico-style QD, add suffix “Q7” (e.g., QS18UNAQ7).
A model with a QD connector requires a mating cable (see page 10).
QS18UNA
QS18UPA
QS18UNAE
QS18UPAE
or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products
which meet OSHA, ANSI and IEC standards for personnel protection.
Model
WARNING . . .
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure
(2" to 20")
Sensing
500 mm
Range
50 mm
to
Not To Be Used for Personnel Protection
• Fast, easy-to-use TEACH-Mode programming; no potentiometer adjustments
• Ultra-compact housing
• One discrete output: NPN or PNP, depending on model
• Two bi-colored status LEDs
• Rugged encapsulated version for harsh environments
• Choose 2 meter or 9 meter unterminated cable, 4-pin Euro-style or
• Wide operating range of -20° to +60° C (-13° to +140° F)
• Temperature compensation
• Configurable for normally open or normally closed operation
• Fast response time (15 milliseconds)
(epoxy-encapsulated,
WORLD BEAM
Miniature Ultrasonic Sensors with TEACH-Mode Programming
Integral push button
4-pin Pico-style QD connectors (either integral or with 150 mm pigtail)
TEACH Options
or remote TEACH
(IP67, NEMA 6P)
IP68, NEMA 6P)
Remote TEACH
Models
• For 4-pin Euro-style 150 mm (6") pigtail QD, add suffix “Q5” (e.g., QS18UNAQ5).
• For 4-pin Pico-style 150 mm (6") pigtail QD, add suffix “Q” (e.g., QS18UNAQ).
®
QS18U Series Ultrasonic Sensors
4-wire, 2 m (6.5') cable
with shield
Cable*
Features
Supply Voltage
12-30V dc
Ultrasonic
Output
NPN
NPN
PNP
PNP

Related parts for QS18UPAE

QS18UPAE Summary of contents

Page 1

... QS18UNAE (2" to 20") QS18UPAE * Only standard 2 m (6.5') cable models are listed. For 9 m (30') shielded cable, add suffix “W/30” to the model number (e.g., QS18UNA W/30). QD models: • For 4-pin integral Euro-style QD, add suffix “Q8” (e.g., QS18UNAQ8). • For 4-pin integral Pico-style QD, add suffix “Q7” (e.g., QS18UNAQ7). ...

Page 2

Sensing Range 50 to 500 mm (2" to 20") Supply Voltage 12 to 30V dc (10% maximum ripple max. (exclusive of load) Ultrasonic Frequency 300 kHz, rep. rate 7.5 ms Supply Protection Protected against reverse polarity and transient ...

Page 3

QS18U Effective Beam Pattern (Typical) NPN (Sinking) Output Models Load wh shield Remote programming switch (normally open recommended that the shield wire be connected to earth ground. Shielded cordsets are recommended for all QD ...

Related keywords