XTOB004CC1 EATON CUTLER HAMMER, XTOB004CC1 Datasheet

Overload Relay

XTOB004CC1

Manufacturer Part Number
XTOB004CC1
Description
Overload Relay
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTOB004CC1

Overload Adjustment Current Min
2.4A
Overload Adjustment Current Max
4A
Coil Voltage Dc Max
220V
Contactor Direction
Non Reversing
Coil Voltage Vdc Nom
220V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
March 2009
CA08102001E
Contents
Description
XT IEC Power Control
IT. Electro-Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-228
For Replacement Only
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-256
Freedom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-261
MMPs & Manual and Combination Motor Controllers . . . . . . . . . . . . . . . . . 34-290
For more information visit: www.eaton.com
Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-2
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-15
Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-30
Overload Relays — XTOB, XTOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-104
Overload Relays — C396 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-113
Manual Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-121
Combination Motor Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-157
Contactors and Starters — Enclosed Control . . . . . . . . . . . . . . . . . . . . . . 34-174
Combination Motor Controllers — Enclosed Control . . . . . . . . . . . . . . . 34-202
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-210
Contactors — Full Voltage, Non-reversing and Reversing . . . . . . . . . . . . 34-230
Starters — Full Voltage, Non-reversing and Reversing. . . . . . . . . . . . . . . 34-233
Contactors — Non-reversing and Reversing . . . . . . . . . . . . . . . . . . . . . . . 34-258
Contactors — Non-reversing and Reversing . . . . . . . . . . . . . . . . . . . . . . . 34-262
Starters — Fixed Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-266
Relays — Fixed Heater Overload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-269
Starters — Interchangeable Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-270
Relays — Interchangeable Heater Overload . . . . . . . . . . . . . . . . . . . . . . . 34-273
Type A302 Manual Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-290
Types A307, A308, A309 Manual Motor Protectors . . . . . . . . . . . . . . . . . 34-294
Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC
IEC Contactors & Starters
Combination Motor Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-300
IEC Contactors and Starters
Page
34-1
34

Related parts for XTOB004CC1

XTOB004CC1 Summary of contents

Page 1

... Description XT IEC Power Control Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-2 Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-15 Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-30 Overload Relays — XTOB, XTOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-104 Overload Relays — C396 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-113 Manual Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-121 Combination Motor Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-157 Contactors and Starters — Enclosed Control . . . . . . . . . . . . . . . . . . . . . . 34-174 Combination Motor Controllers — ...

Page 2

IEC Contactors & Starters 34-2 XT IEC Power Control Relays and Timers Contents Description Catalog Number Selection . . . . . . . . . . . . . . . Product Selection . . . . . . ...

Page 3

March 2009 Catalog Number Selection Table 34-1. XT — Relay Catalog Numbering System Product Line Prefix = IEC Power Control Product Family Code RM = Mini IEC Control Relay RE = IEC Control Relay Terminations Blank = Screw Terminals C ...

Page 4

IEC Contactors & Starters 34-4 XT IEC Power Control Relays and Timers Product Selection Mini Control Relays 34 Table 34-3. Mini Control Relays Conventional Contact Rated Operational Current AC- (A) Thermal Configuration Current 220 – 240V I th ...

Page 5

March 2009 Accessories Auxiliary Contacts Table 34-6. Front Mount Auxiliary Contacts for Use with XTRM Mini Control Relays Conventional Rated Operational Contact thermal current, Current AC- (A) Configuration I th Open (A) 220V 380V 500V 230V 400V 240V ...

Page 6

IEC Contactors & Starters 34-6 XT IEC Power Control Relays and Timers Table 34-7. Front Mount Auxiliary Contacts for Use with XTRE Control Relays Conventional Poles Thermal Current (A), Open at 60° ...

Page 7

March 2009 Varistor Suppressor with Integrated LED A1 A2 Table 34-10. Varistor Suppressor for XTRE Voltage For Use Pkg. Catalog with… Qty. Number 24 – 48 XTRE(C)10B 10 XTCEXVSLBW 130 – 240 10 XTCEXVSLBB Note drop-out delay. For AC operated ...

Page 8

IEC Contactors & Starters 34-8 XT IEC Power Control Relays and Timers Connector Table 34-15. Connector For Use with… XTRE(C)10B 34 XTRM10A For mechanically arranging contactors in combinations. Distance between contactors is 0 mm. Orders must be placed in multiples ...

Page 9

March 2009 Mini Electronic Timers Table 34-18. Mini Electronic On-Delay Timers Conventional Rated Operational Current Thermal Current I e AC-11 Amps I e (A) 220/230/240V 380/400/440V Notes — Actuating Voltage 24 ...

Page 10

IEC Contactors & Starters 34-10 XT IEC Power Control Relays and Timers Technical Data and Specifications Table 34-20. Relays and Timers — Technical Data and Specifications Description General Standards 34 Lifespan, Mechanical AC Operated DC Operated Maximum operating frequency (ops/hr) ...

Page 11

March 2009 Table 34-20. Relays and Timers — Technical Data and Specifications (Continued) Description Contacts (Continued) DC-13 DC13 L/R ≤ Contacts in series: Voltage: 1 24V 1 60V 2 60V 1 110V 110V 3 1 220V 3 220V ...

Page 12

IEC Contactors & Starters 34-12 XT IEC Power Control Relays and Timers Control Relays Component lifespan (operations Rated operational current 0.5 AC-15 0.2 240 V 0.1 0.01 0.02 0.05 ...

Page 13

March 2009 Flow Diagrams — Electronic Timers XTMT Mini Timers A1-A2 15-18 t LED Figure 34-4. On-Delayed A1-A2 15-18 OFF ON OFF LED Figure 34-5. ON-OFF Function A1-A2 15-18 t LED Figure 34-6. Fleeting Contact on Energization A1-A2 15-18 t ...

Page 14

IEC Contactors & Starters 34-14 XT IEC Power Control Relays and Timers Control Relays [2.68] [1.77] [.71] 18 [.71] 45 [1.77] Figure 34-14. Control Relay XTRE with XTCEXFA Auxiliary Contact — Approximate Dimensions in mm [in.] ...

Page 15

... Catalog Number Selection . . . . . . . . . . . . . . . . 34-16 Product Selection . . . . . . . . . . 34-17 Non-reversing Mini Contactors . . . . . . . . 34-17 Reversing Mini Contactors . . . . . . . . . . . . 34-17 Star-Delta (Wye-Delta) Miniature Contactors . . . 34-19 Overload Relays . . . . . . . . . 34-20 Accessories . . . . . . . . . . . . . . . 34-21 Technical Data and Specifications . . . . . . . . . . . . 34-24 Dimensions . . . . . . . . . . . . . . . 34-29 Reference Data . . . . . . . . . . . . 34-210 XTMC Mini Contactor Product Description ® ...

Page 16

... IEC Power Control Type MC = 3-Pole FVNR Mini IEC Contactor MF = 4-Pole FVNR Mini IEC Contactor MR = 3-Pole FVR Mini IEC Contactor Terminations Blank Screw Terminals = Spring Cage Terminals C = Table 34-23. XT IEC Miniature Overload Relays — Catalog Numbering System Designation = IEC Power Control OM = Mini Overload Relay ...

Page 17

... Coil 1NO XTMC6A10_ XTMCC6A10_ 1NC XTMC6A01_ XTMCC6A01_ 1NO XTMC9A10_ XTMCC9A10_ 1NC XTMC9A01_ XTMCC9A01_ — XTMF9A00_ — Spare Auxiliary Catalog Price Contacts Number U.S. $ K1M K2M AC DC XTMR6A21_ XTMR9A21_ Overload Relays . . . . . . . . . . . . . . . . . . Page 34-20 Accessories . . . . . . . . . . . . . . . . . . . . . . Page 34-21 Dimensions . . . . . . . . . . . . . . . . . . . . . . Page 34-29 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 34 ...

Page 18

IEC Contactors & Starters 34-18 XT IEC Power Control Miniature Controls Table 34-26. Magnet Coil Suffix Coil Voltage Suffix Code 110V 50 Hz, 120V 220V 50 Hz, 240V 230V 24V 50/60 ...

Page 19

... K3M Star XTMC9A10_ Contactor K3M Auxiliary XTMCXFC02 Contact K1T Timing XTTR6A60S51B Relay Suffix Coil Voltage Suffix Code Code N 120V 220V 12V 48V — — Y — — Overload Relays . . . . . . . . . . . . . . . . . . Page 34-20 Accessories . . . . . . . . . . . . . . . . . . . . . . Page 34-21 Dimensions . . . . . . . . . . . . . . . . . . . . . . Page 34-29 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 34-19 34 ...

Page 20

... Short-circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. See MN03402002E for more information. When fitted directly to the contactor, a clearance of at least required between the overload relays. Tripping Characteristics Chart These tripping characteristics are mean values of the spread at 20° ...

Page 21

March 2009 Accessories Auxiliary Contacts Front mounted snap-on auxiliary contacts for mini contactors are available with screw or spring cage terminals in a variety of contact configurations. Auxiliary contact modules are standard with interlocked opposing contacts, except in the case ...

Page 22

IEC Contactors & Starters 34-22 XT IEC Power Control Miniature Controls RC Suppressor 34 Table 34-32. RC Suppressor Voltage For Use Circuit with… Symbol 24 – 48 XTMC6A…, A1 XTMC9A… 48 – 130 XTMC6A…, XTMC9A… A2 110 – 250 XTMC6A…, ...

Page 23

March 2009 Star-Delta (Wye-Delta) Bridge Table 34-37. Star-Delta (Wye-Delta) Bridge Contact Sequence Package Catalog Qty. Number 20 XTMCXSDB Orders must be placed in multiples of package quantity listed. Protected against direct contact in accordance with IEC 536. Paralleling Link Set ...

Page 24

IEC Contactors & Starters 34-24 XT IEC Power Control Miniature Controls Technical Data and Specifications Table 34-41. XT Miniature Controls — General Specifications Description Physical and Electrical (Continued) Standards 34 Weights in kg [lb] Mechanical Life — Operations Mechanical Life ...

Page 25

March 2009 Table 34-42. XT Miniature Controls — Magnet Systems Description Voltage Tolerance Pick- Single-voltage coil 50 Hz and dual-voltage coil 50 Hz Dual frequency coil 50/ operated Power Consumption AC Operation ...

Page 26

IEC Contactors & Starters 34-26 XT IEC Power Control Miniature Controls Table 34-43. XT Miniature Controls Description AC-1 Operation Conventional free air thermal current, 3-pole, 50 – (A) at 40° 50° ...

Page 27

March 2009 Table 34-45. XT Miniature Controls — Auxiliary Contacts Description Interlocked opposing contacts to ZH1/457, including auxiliary contact module Rated impulse withstand voltage, U imp (VAC) Overvoltage category / pollution degree Rated insulation voltage (VAC) Rated operational ...

Page 28

IEC Contactors & Starters 34-28 XT IEC Power Control Miniature Controls Electrical Switching Operation Charts Squirrel-cage motors Operating characteristics Starting: from rest Stopping: after attaining a full running speed Electrical Characteristics — Make (NO rated motor current ...

Page 29

March 2009 Dimensions D 58 [2.28 [1.77] XTMC XTMCC D 52 [2.05] 54 [2.13 [3.27] 86 [3.39] Figure 34-27. Non-reversing Mini Contactor 61 [2.40] 180 [7.09] 108 [4.25] Figure 34-28. Star-Delta Starter Combinations 61 [2.40] 108 ...

Page 30

... Contactors and Starters 34-42 Product Description 34-42 Eaton’s new line of Contactors and Starters includes non-reversing and 34-44 reversing contactors, overload relays 34-49 and a variety of related accessories. Because meets IEC, UL, CSA, 34-61 CCC and CE standards the perfect product solution for IEC applications 34-62 all over the world ...

Page 31

... Coils for Special Voltages “Safe Isolation” to IEC 536 between coil and contacts Suppressors ■ suppressor 34-55 ■ Varistor suppressor ■ Free-wheel diode suppressor Overload Relays ■ 3 Can be mounted directly 34-104 ■ Separate mounting, possible ■ Protection of EEx e motors Auxiliary Contact Modules ■ 4 ...

Page 32

... Control circuit terminal ■ Cover for fingerproofing Mechanical Interlock ■ 4 Fits between contactors 34-57 Overload Relays ■ 5 Can be mounted directly 34-104 ■ Separate mounting, possible ■ Protection of EEx e motors ■ PTB certificate Terminal Shroud ■ ...

Page 33

March 2009 Catalog Number Selection Table 34-48. XT IEC Contactors & Starters — Catalog Numbering System Designation = Line of IEC Control Type CE ...

Page 34

... Frame B – C contactors with 1NC built-in auxiliary are mirror contacts (XTCE...B01_ – XTCE...C01_). Contact Sequence (Circuit Symbols Page 34-35 Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-38 Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 March 2009 DC Coil CA08102001E ...

Page 35

... XTCE300M22_ 2NO-2NC XTCE400M22_ 2NO-2NC XTCE500M22_ 2NO-2NC XTCE570M22_ 2NO-2NC XTCE580N22_ 2NO-2NC XTCE650N22_ 2NO-2NC XTCE750N22_ 2NO-2NC XTCE820N22_ 2NO-2NC XTCEC10N22_ 2NO-2NC XTCEC14P22_ 2NO-2NC XTCEC16R22_ 2NO-2NC XTCEC20R22_ Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-38 Accessories . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 34 ...

Page 36

... A 24V output from the PLC can be connected directly to connections A3/A4. From Low-Consumption Command Devices Command devices which can only be subject to minimal loads such as circuit board relays, control circuit devices or position switches can be connected directly to A10/A11. Standstill in an emergency (Emergency-Stop). Command device connection, ...

Page 37

... AC Coil DC Coil XTCR007B21_ XTCR009B21_ XTCR012B21_ XTCR018C21_ XTCR025C21_ XTCR032C21_ — XTCR040D11_ — XTCR050D11_ — XTCR065D11_ — XTCR080F11_ — XTCR095F11_ — XTCR115G11_ — XTCR150G11_ Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-38 Accessories . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 34-37 34 ...

Page 38

... Hz/DC A 250 – 500V 40 – – 110V 40 – 60 Hz/ – 48V DC TD Frame L – M, S-Series 110 – 120V 50/ 220 – 240V 50/ Frame P – R 220 – 250V 50 – 60 Hz/ Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 March 2009 CA08102001E ...

Page 39

... XTAE065D00_ _ — — XTAE080F00_ _ — — XTAE095F00_ _ — — XTAE115G00_ _ — — XTAE150G00_ _ 108 2NO-2NC XTAE185L22_ _ 108 2NO-2NC XTAE225L22_ _ 108 2NO-2NC XTAE250L22_ _ Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-40 Accessories . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 34-39 34 ...

Page 40

... DC TD Frame L – N, S-Series 110 – 120V 50/ 220 – 240V 50/ Frame P – R 220 – 250V 50 – 60 Hz/DC B Frame C – D only. Frame L – M only. Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 CA08102001E March 2009 DC Coil DC Coil ...

Page 41

... XTOBP40CC1 50 – 70 070 XTOBP60CC1 70 – 100 100 XTOB001CC1 95 – 125 125 XTOB1P6CC1 120 – 150 150 XTOB2P4CC1 145 – 175 175 XTOB004CC1 Frame L XTOB006CC1 50 – 70 070 XTOB010CC1 70 – 100 100 XTOB016CC1 95 – 125 125 XTOB024CC1 XTOB032CC1 120 – 160 160 160 – 220 220 200 – ...

Page 42

... AC Coil 690V 4 3.5 XTAR007B21_ _ 5.5 4.5 XTAR009B21_ _ 7 6.5 XTAR012B21_ XTAR018C21_ _ 14.5 14 XTAR025C21_ XTAR032C21_ XTAR040D11_ XTAR050D11_ XTAR065D11_ _ Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-43 Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-113 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 March 2009 DC Coil DC Coil CA08102001E ...

Page 43

... Hz/DC A 250 – 500V 40 – – 110V 40 – 60 Hz/ – 48V DC TD Frame L – N, S-Series 110 – 120V 50/ 220 – 240V 50/ Frame P – R 220 – 250V 50 – 60 Hz/DC B Accessories . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-113 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 34 ...

Page 44

IEC Contactors & Starters 34-44 XT IEC Power Control Contactors and Starters Star-Delta (Wye-Delta) Starters Table 34-70. Star-Delta (Wye-Delta) Starters Maximum 3-Phase Current I e (A) Motor Rating 3-Phase hp Ratings AC-3 200V 230V 460V 575V 34 Frame B 3 ...

Page 45

March 2009 Table 34-70. Star-Delta (Wye-Delta) Starters (Continued) Maximum 3-Phase Current I e (A) Maximum kW Ratings AC-3 Motor Rating 3-Phase hp Ratings AC-3 3-Phase Motors 50 – 200V 230V 460V 575V 220/ 380/ 230V 400V Frame D ...

Page 46

... K1M Main Contactor XTCEC10N22_ K5M Delta Contactor XTCEC10N22_ K3M Star Contactor XTCE650N22_ Mechanical Interlock XTCEXMLN K1T Timing Relay XTTR6A60S51B Overload Relay XTOT…C3S Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-47 Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 CA08102001E ...

Page 47

... Hz/ – 48V DC TD Frame L – M, S-Series 110 – 120V 50/ 220 – 240V 50/ Frame P – R 220 – 250V 50 – 60 Hz/ S11 K1M K1M K3M K5M 22 22 K5M K3M K1M K1T K3M K5M (–) – 1700A AC-3 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 34 ...

Page 48

IEC Contactors & Starters 34-48 XT IEC Power Control Contactors and Starters 34 Table 34-73. XTCC Contactors for Three-Phase Capacitors Three-Phase Capacitors, 50 – Open kVar Ratings 230V 400V 525V 690V 33 33.3 ...

Page 49

March 2009 Accessories Auxiliary Contacts Front mounted snap-on auxiliary con- tacts for contactors are available with screw or spring cage terminals in a variety of contact configurations. Table 34-76. XTCE and XTCS Auxiliary Contact Overview Frame A B Catalog XTMC6A... ...

Page 50

IEC Contactors & Starters 34-50 XT IEC Power Control Contactors and Starters Table 34-77. Auxiliary Contacts Conventional Thermal Current, Open at 60° AC-1 in Amps Frame B – C — Front (Top) Mount 16 ...

Page 51

March 2009 Table 34-77. Auxiliary Contacts (Continued) Conventional Poles Thermal Current, Open at 60° AC-1 in Amps Frame B – C — Front (Top) Mount — Tall Version ...

Page 52

IEC Contactors & Starters 34-52 XT IEC Power Control Contactors and Starters Table 34-78. Side Mount Auxiliary Contacts for Frame D – – 2000A Conventional Free Air Thermal Current AC-1 in Amps ...

Page 53

March 2009 Table 34-79. Auxiliary Contacts Possible Combinations Frame Catalog Contactor Size Number A XTMC6A… – XTMC9A… B XTCE007B… – XTCE015B… C XTCE018C… – XTCE032C… D XTCE040D00_ – XTCE065D00_ F – G XTCE080F00_ – XTCE150G00_ L – R XTCE185L22_ – ...

Page 54

IEC Contactors & Starters 34-54 XT IEC Power Control Contactors and Starters 34 + XTCE007B... – XTCE015B... Not for use with mechanical interlock. XTCE007B... – XTCE032C... XTCEXF...C... 2-Pole or 4-Pole XTCE040D... – XTCE065D... XTCEXF...G... + 2-Pole XTCE080F... – XTCE150G... XTCEXF...G... ...

Page 55

March 2009 Suppressors The switching of contactor coils can generate voltage tran- sients that may cause arching on switch contacts and/or damage electronics on the control line. Either Varis- tor Suppressor is recommended in these types of ...

Page 56

IEC Contactors & Starters 34-56 XT IEC Power Control Contactors and Starters Electronic Timer Modules Table 34-85. Electronic Timer Modules for Frame B – C Contactors (7 – 32A) Voltage On-Delayed 24V AC/DC 34 100 – 130V AC 200 – ...

Page 57

March 2009 Mechanical Interlock Table 34-86. Mechanical Interlock For Use Pkg. Catalog with… Qty. Number XTCE007B – XTCE015B, 5 XTCEXMLB XTCF020B XTCE018C – XTCE032C 1 XTCEXMLC XTCF032C – XTCF045C XTCE040D – XTCE072D 1 XTCEXMLD XTCF063D – XTCF080D XTCE080F – XTCE170G ...

Page 58

IEC Contactors & Starters 34-58 XT IEC Power Control Contactors and Starters Reversing Bridge Component part of Reversing Link Kit (XTCEXRL_). Reverses the phases on the load-side of two contactors. 34 Table 34-90. Reversing Bridge For Use with… XTCE007B – ...

Page 59

March 2009 Parallel Link For using one contactor per phase. Each package comes with (2) links for line: load. Table 34-95. Parallel Link For Use Pkg. Catalog with… Qty. Number XTCE007B – 5 XTCEXPLKB XTCE015B XTCE018C – 5 XTCEXPLKC XTCE032C ...

Page 60

IEC Contactors & Starters 34-60 XT IEC Power Control Contactors and Starters Control Wire Terminal Extension 34 Fits to Frame F – G contactors and allows connection of con- trol wire to power terminals. Table 34-101. Control Wire Terminal Extension ...

Page 61

March 2009 Renewal Parts Table 34-103. Replacement Coils Voltage Coil Catalog Suffix Number Frame C 110/50 120/60 A XTCERENCOILCA 110 – 130V DC AD XTCERENCOILCAD 220/50 240/60 B XTCERENCOILCB 200 – 240V DC BD XTCERENCOILCBD 415/50 480/60 C XTCERENCOILCC 550/50 ...

Page 62

... XTCE 3-Pole Contactors . . . . XTCE Coil Data . . . . . . . . . . . . 34 XTCF 4-Pole Contactors . . . . XTCF Coil Data . . . . . . . . . . . . Auxiliary Contacts . . . . . . . . . AC Ratings . . . . . . . . . . . . . . . DC Ratings . . . . . . . . . . . . . . . Heat Loss . . . . . . . . . . . . . . . . Life Curves . . . . . . . . . . . . . . . Overload Relays . . . . . . . . . . . Type 2 Coordination . . . . . . . XT Contactors Frame B Table 34-107. XT Contactors Technical Data and Specifications — Frame B Description General Standards Weights in kg [Lb] AC operated ...

Page 63

March 2009 Table 34-107. XT Contactors Technical Data and Specifications — Frame B (Continued) Description General (Continued) Terminal Capacity Main Cable — Screw Terminals 2 Solid ( Flexible with ferrule (mm ) Solid or Stranded (AWG) Terminal Capacity ...

Page 64

IEC Contactors & Starters 34-64 XT IEC Power Control Contactors and Starters Frame C – D Table 34-108. XT Contactors Technical Data and Specifications — Frame C – D Description General Standards 34 Weights in kg [Lb] AC operated DC ...

Page 65

March 2009 Table 34-108. XT Contactors Technical Data and Specifications — Frame C – D (Continued) Description General (Continued) Tools Main and Control Circuit Cable — Screw Terminals Pozidriv screwdriver Standard screwdriver Terminal Capacity Control Circuit Cable — Spring Cage ...

Page 66

IEC Contactors & Starters 34-66 XT IEC Power Control Contactors and Starters Frame F – G Table 34-109. XT Contactors Technical Data and Specifications — Frame F – G Description General Standards Weights in kg [Lb operated DC ...

Page 67

March 2009 Table 34-109. XT Contactors Technical Data and Specifications — Frame F – G (Continued) Description General (Continued) Tools Main Circuit Cable — Screw Terminals Hexagon Socket-Head Spanner (mm) Control Circuit Cable — Screw Terminals Pozidriv screwdriver Standard screwdriver ...

Page 68

IEC Contactors & Starters 34-68 XT IEC Power Control Contactors and Starters Frame L – M Table 34-110. XT Contactors Technical Data and Specifications — Frame L – M Description General Standards 34 Weights in kg [Lb] Mechanical Life Mechanical ...

Page 69

March 2009 Table 34-110. XT Contactors Technical Data and Specifications — Frame L – M (Continued) Description XTCE185L, XTCE225L, XTCS185L XTCS225L General (Continued) Mounting Position, AC and DC Operated Ambient Temperature -25 to 60°C -25 to 60°C [-13 to 140°F] ...

Page 70

IEC Contactors & Starters 34-70 XT IEC Power Control Contactors and Starters Frame N – R Table 34-111. XT Contactors Technical Data and Specifications — Frame N – R Description General Standards 34 Weights in kg [Lb] Mechanical Life Mechanical ...

Page 71

... C Frame XTCE and XTCEC Contactors and Accessories (Inside of Packaging) Pub51221 XTOB, D Frame Overload Relays (Inside of Packaging) Pub51222 XTOB, B – C Frame Overload Relays (Inside of Packaging) Pub51237 7 – 12A, B Frame XTCE Contactors and Auxiliary Contacts Pub51232 18 – 32A, C Frame XTCE Contactors and Auxiliary Contacts Pub51216 40 – ...

Page 72

IEC Contactors & Starters 34-72 XT IEC Power Control Contactors and Starters Coil Data Frame B – D Table 34-113. Coil Data — Frame B – D Description XTCE007B Voltage Tolerance 34 Pick- operated 0.8 ...

Page 73

March 2009 Frame F – G Table 34-114. Coil Data — Frame F – G Description Voltage Tolerance Pick- operated DC operated Drop-Out ( operated DC operated Power Consumption of the ...

Page 74

... Drop-out of the contactor Time is bridged successfully Drop-out of the contactor Contactor remains switched on Contactor remains switched on Contactor remains switched on Drop-out of the contactor Contactor does not switch on Contactor switches on with certainty Contactor switches on with certainty ≤500 ≤500 ≤1 ≤1 15V 15V 5V 5V This product is designed for operation in industrial environments. Usage in domestic areas can cause radio frequency interference (RFI) ...

Page 75

... Drop-out of the contactor Time is bridged successfully Drop-out of the contactor Contactor remains switched on Contactor remains switched on Contactor remains switched on Drop-out of the contactor Contactor does not switch on Contactor switches on with certainty Contactor switches on with certainty ≤500 ≤500 ≤500 ≤1 ≤1 ≤1 15V 15V ...

Page 76

IEC Contactors & Starters 34-76 XT IEC Power Control Contactors and Starters Contactor Contact Travel Diagrams The diagrams indicate the closing and travel of the contacts of the contactors and auxiliary contacts at no-load. Tolerances are not taken into consideration. ...

Page 77

March 2009 Table 34-116. XT Contactors Technical Data and Specifications — 4-Pole Description General Standards Weights in kg [Lb] AC operated DC operated Mechanical Life Mechanical Operating Frequency (ops/hr) AC operated DC operated Electrical Life Electrical Operating Frequency (ops/hr) Climatic ...

Page 78

IEC Contactors & Starters 34-78 XT IEC Power Control Contactors and Starters Table 34-116. XT Contactors Technical Data and Specifications — 4-pole (Continued) Description General Mounting Position, AC & DC Operated 34 Ambient Temperature Open Enclosed Ambient Storage Temperature Environmental ...

Page 79

March 2009 Auxiliary Contacts Table 34-117. Auxiliary Contacts Technical Data and Specifications Description XTCE007B…– XTCE032C Interlocked opposing contacts with an auxiliary — contact module (to IEC 60947-5 -1 Annex L) Break contact (not late-break contact) XTCE007B… – suitable as a ...

Page 80

IEC Contactors & Starters 34-80 XT IEC Power Control Contactors and Starters AC Ratings Table 34-120. AC Ratings Description AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 – Open at 40° 50°C ...

Page 81

March 2009 Table 34-120. AC Ratings (Continued) Description XTCE040D AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 – Open at 40° 60A at 50° 57A at 55° 55A ...

Page 82

IEC Contactors & Starters 34-82 XT IEC Power Control Contactors and Starters Table 34-120. AC Ratings (Continued) Description AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 – 40° 50° ...

Page 83

March 2009 Table 34-120. AC Ratings (Continued) Description AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 – 40° 50° 55° 60° ...

Page 84

IEC Contactors & Starters 34-84 XT IEC Power Control Contactors and Starters Table 34-121. AC Ratings — 4-Pole Description AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50-60 Hz Open (Amps) at 40° 50° ...

Page 85

March 2009 DC Ratings Table 34-122. DC Ratings — DC-1 Description XTCE007B Rated operation current { amperes e 60V 110V 220V 440V XTCE040D 60V 110V 220V 440V XTCE185L 60V 300 110V 300 220V 300 440V XTCE650N 60V ...

Page 86

IEC Contactors & Starters 34-86 XT IEC Power Control Contactors and Starters Table 34-124. DC Ratings — DC-5 Description Rated operation current { amperes 60V 110V 220V 440V 34 60V 110V 220V 440V 60V 110V 220V ...

Page 87

March 2009 Heat Loss Table 34-126. Current Heat Loss (3-Pole) in Watts Description XTCE007B Current heat loss (3-Pole) in watts AC-3/400V 0.37 Impedance per pole, mΩ 2.5 XTCE040D Current heat loss (3-Pole) ...

Page 88

IEC Contactors & Starters 34-88 XT IEC Power Control Contactors and Starters Life Curves 170 XTCE170G 75 150 XTCE150G 34 55 115 XTCE115G 45 95 XTCE095F 37 XTCE065D 18.5 XTCE040D XTCE032C 15 ...

Page 89

March 2009 XTCF200G 200 160 XTCF160G XTCF125G 125 XTCF080D 80 63 XTCF063D 45 XTCF045C 32 XTCF032C 22 XTCF020B 0.1 0.2 0.4 0.6 Component Lifespan (millions of operations) Figure 34-41. Switching Duty for Non-motor Loads, 4-Pole — XTCF020B – XTCF200G A ...

Page 90

IEC Contactors & Starters 34-90 XT IEC Power Control Contactors and Starters 2000 XTCEC20R XTCEC16R 1800 1400 XTCEC14P XTCE 0N XTCE750N 900 XTCE580N 800 XTCE400M 500 XTCE300M 34 XTCE150G, XTCE170G E1 160 130 110 XTCE080F XTCE080F 80 65 XTMC9A 20 ...

Page 91

March 2009 Dimensions XTCE Contactors (3-Pole) 36 [1.42] 68 [2.68] 18 [.71] 45 [1.77] 8.7 [.34] Typ. 5.1 [.20] 45 [1.77] Figure 34-46. Frame B, XTCE007B and XTCE015B Contactors with Screw Terminals (7 – 15A) XTCF020B — Approximate Dimensions in ...

Page 92

IEC Contactors & Starters 34-92 XT IEC Power Control Contactors and Starters 34 57 [2.24] 86.4 [3.40] 34.4 [1.35] 55 [2.17] Figure 34-49. Frame D, XTCE040D – XTCE072D Contactors (40 – 75A) — Approximate Dimensions in mm [in] 90 [3.54] ...

Page 93

March 2009 [.43] Dia Frame L 140 [5.51] 160 [6.30] 120 [4.72] (185 – 250A) Frame M 160 [6.30] 180 [7.09] 130 [5.12] (300A – 400A) Frame M 160 [6.30] 180 ...

Page 94

IEC Contactors & Starters 34-94 XT IEC Power Control Contactors and Starters 34 14 [.55] 60 Dia. [2.36] 100 100 [3.94] [3.94] 260 [10.24] Figure 34-53. Frame P, XTCEC14P Contactor (1400A, AC-1) — Approximate Dimensions in mm [in] 14 [.55] ...

Page 95

March 2009 XTCF Contactors (4-Pole) 45.0 18.0 [1.77] [0.71] 68.0 [2.68] 36.0 [1.42] 45.0 [1.77] Figure 34-55. Frame B, XTCF020B Contactors — Approximate Dimensions in mm [in] 85.0 [3.35] 60.0 38.0 [1.50] 71.0 [2.80] 58.0 [2.28] Figure 34-56. Frame C, ...

Page 96

IEC Contactors & Starters 34-96 XT IEC Power Control Contactors and Starters 34 122.0 [4.80] 133.0 [5.24] Figure 34-58. Frame G, XTCF125G – XTCF200G Contactors — Approximate Dimensions in mm [in] 170.0 [6.69] 57.0 156.0 [2.24] [6.14] 82.5 [3.25] 85.5 ...

Page 97

March 2009 XTAE Starters with XTOB Overload Relay Mounting 45.3 Holes for [1.78 Screws 75 Places) [2.98] [1.38] 60 [2.36] 117.8 [4.64] 83.3 [3.28] 88.4 [3.48] To Reset Figure 34-59. Frame B, XTAE007B – XTAE012B ...

Page 98

IEC Contactors & Starters 34-98 XT IEC Power Control Contactors and Starters 34 156 [6.14] 277 [10.91] 91 [3.58] 7 [.276] Dia. Figure 34-62. Frame F – G, XTAE080F – XTAE150G Starters with XTOB (80 – 150A) — Approximate Dimensions ...

Page 99

March 2009 XTAE Starters with C396 Overload Relay 45.3 Mounting 117.0 [1.78] Holes for [4.61 75.8 35 Screws [2.98] [1.38] (4 Places) 60 [2.36] 91.8 [3.61] 126.4 [4.98] 6.2 88.1 [.24] [3.47] Figure 34-64. Frame B, XTAE007B ...

Page 100

IEC Contactors & Starters 34-100 XT IEC Power Control Contactors and Starters Reversing Combination 34 Frame B (7 – 15A [3.54] Figure 34-69. XTCR Reversing Combination Frame B – D — Approximate Dimensions in mm [in] 176 [6.93] ...

Page 101

March 2009 Star-Delta Combination W Frame 158 68 [6.22] [2.68] Figure 34-71. Star-Delta Combination Frame B – D — Approximate Dimensions in mm [in] 144 [5.67] 308 [12.13] Figure 34-72. Star-Delta Combination Frame F – G — ...

Page 102

IEC Contactors & Starters 34-102 XT IEC Power Control Contactors and Starters Mechanical Interlock 15 [.59] 34 Figure 34-73. Frame L – M. XTCEXMLM Mechanical Interlock — Approximate Dimensions in mm [in] 515 [20.28] 430 [16.93] 270 [10.63] 300 [11.81] ...

Page 103

March 2009 Suppressor XTCEXRSB... 25 9.2 25.9 28 XTCEXVSB... [.98] [.36] [1.02] [1.10] XTCEXVSLB... XTCEXDSB... XTCEXRSC... 25 9 XTCEXVSC... [.98] [.36] [.63] [1.10] XTCEXVSLC... XTCEXRSF... 25 20 18.5 28 XTCEXVSF... [.98] ...

Page 104

... Overload Relays — XTOB, XTOT Catalog Number Selection . . . . . . . . . . . . . . . Product Selection . . . . . . . . . 34 Accessories . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . Reference Data . . . . . . . . . . . . Catalog Number Selection Table 34-128. XT IEC Overload Relays — Catalog Numbering System Designation = Line of IEC Control Type OB = Bimetallic Overload Relay OT = Current Transformer Overload Relay Frame B P16 = ...

Page 105

... XTOB012BC1 30 45 XTOB016BC1 25 3 XTOBP16CC1 25 3 XTOBP24CC1 25 3 XTOBP40CC1 25 3 XTOBP60CC1 25 3 XTOB001CC1 25 6 XTOB1P6CC1 25 6 XTOB2P4CC1 25 15 XTOB004CC1 25 20 XTOB006CC1 25 25 XTOB010CC1 30 25 XTOB016CC1 30 25 XTOB024CC1 30 25 XTOB032CC1 25 25 XTOB010DC1 25 25 XTOB016DC1 30 25 XTOB024DC1 125 125 XTOB040DC1 150 150 ...

Page 106

... IEC Contactors & Starters 34-106 XT IEC Power Control Overload Relays — XTOB, XTOT Table 34-130. Current Transformer Operated Overload Relays Overload Contact Releases Sequence Frame M – N — Separate Mount 42 – – – 125 110 – 160 160 – 240 190 – 290 270 – ...

Page 107

... Figure 34-80. Overload Fitted Directly to the Contactor Frame C (18 – 32A) Figure 34-81. Overload Mounted Separately from the Contactor CA08102001E IEC Contactors & Starters XT IEC Power Control Overload Relays — XTOB, XTOT Frame D Frame F – G (40 – 72A) (80 – 170A) Frame F – G (80 – 170A) Frame D (40 – ...

Page 108

... IEC Contactors & Starters 34-108 XT IEC Power Control Overload Relays — XTOB, XTOT Technical Data and Specifications Table 34-135. XTOB Overload Relay — Technical Data and Specifications Description General Standards Climate Proofing 34 Ambient Temperature Temperature Compensation Mechanical Shock Resistance (IEC/EN 60068-2-27) ...

Page 109

... Table 34-136. Instructional Leaflets Publication Description Number Pub51221 XTOB, D Frame Overload Relays (Inside of Packaging) Pub51222 XTOB, B – C Frame Overload Relays (Inside of Packaging) CA08102001E IEC Contactors & Starters XT IEC Power Control Overload Relays — XTOB, XTOT XTOB…BC1, XTOB…CC1 XTOB…DC1 1.5 1 ...

Page 110

... Overload Relays — XTOB, XTOT Dimensions 34 29.5 39.5 [1.16] [1.56] 45 [1.77] Figure 34-83. Frame B – C, XTOB…BC1 and XTOB…CC1 Overload Relays — Approximate Dimensions in mm [in] 20.3 [.80] 79.2 [3.12] 60 [2.36] Figure 34-84. Frame D, XTOB…DC1 Overload Relay — Approximate Dimensions in mm [in ...

Page 111

... Figure 34-87. Frame F – G, XTOB…G1CS Overload Relay — Approximate Dimensions in mm [in] CA08102001E IEC Contactors & Starters XT IEC Power Control Overload Relays — XTOB, XTOT 73 [2.87] 63 [2.48] 129 [5.08] 134 [5.28] 63 [2.48] 129 [5.08] 134 [5.28] For more information visit: www ...

Page 112

... IEC Contactors & Starters 34-112 XT IEC Power Control Overload Relays — XTOB, XTOT 110 [4.33] 121 [4.76] 96 [3.78] 48 [1.89 [2.91] 7 [.28 [.20 16.5 [.98] [.65] 128 [5.04] Figure 34-88. Frame L, XTOB…LC1 Overload Relay — Approximate Dimensions in mm [in] Current Transformer Operated Overload Relay 185 [7 ...

Page 113

... Accessories . . . . . . . . . . . . . . . 34-115 Technical Data and Specifications . . . . . . . . . . . . 34-116 Dimensions . . . . . . . . . . . . . . . 34-117 Reference Data . . . . . . . . . . . . 34-210 C396 Electronic Overload Relay Catalog Number Selection Table 34-137. C396 Electronic Overload Relays — Catalog Numbering System Device Type C396 = C396 Electronic Overload Relay Frame Size 110 mm Feature Set ...

Page 114

... IEC Contactors & Starters 34-114 XT IEC Power Control Overload Relays — C396 Product Selection 34 Frame C XT Starter with Cat. No. C396C3A150SELAX C396 Electronic Overload with C396CBARXT Table 34-138. C396 Stand-Alone Overload Relay FLA Range Description Catalog (Amps) Number 45 mm Overload Frame Size 0.1 – ...

Page 115

... Must be cut to proper length — uncut 4.72 inches (119.9 mm) long. Enables a 22.5 mm operator to be mounted in a 30.5 mm holes — 1/16 to 7/32 inch (1.6 to 5.6 mm) panel thickness. CA08102001E IEC Contactors & Starters XT IEC Power Control Overload Relays — C396 Catalog Price Number U.S. $ C396ARST ...

Page 116

... IEC Contactors & Starters 34-116 XT IEC Power Control Overload Relays — C396 Technical Data and Specifications Table 34-142. Overload Relay Specifications General C396_2_ Description Standard Protection 34 Thermal 1.05 x FLA: Does not trip 1.25 x FLA: Overload trip Phase Loss 1 Phase = 0, Trip time = 3s (Hot Status) Phase Imbalance Max - Min / Max > ...

Page 117

... Figure 34-91 Stand-Alone C396 Electronic Overload Relay — Approximate Dimensions in mm [in] CA08102001E IEC Contactors & Starters XT IEC Power Control Overload Relays — C396 91.5 [3.60] 59.5 [2.34] 5.0 86.5 [3.41] 114.0 [4.49] For more information visit: www.eaton.com 34-117 82 ...

Page 118

... IEC Contactors & Starters 34-118 XT IEC Power Control Overload Relays — C396 96.5 [3.80] 34 6.4 [.25] 94.0 [3.70] 96.5 [3.80] Figure 34-92. 110 mm Stand-Alone C396 Electronic Overload Relay — Approximate Dimensions in mm [in] 8.4 [.33] 8.7 [.34] 2.0 [.08] 69.5 [2.74] 45.0 [1.77] Figure 34-93 C396 (0.1 – 8A) Direct Connect to XT Frame B Contactor — ...

Page 119

... Figure 34-96 C396 (6.4 – 32A) Direct Connect to XT Frame C Contactor — Approximate Dimensions in mm [in] CA08102001E IEC Contactors & Starters XT IEC Power Control Overload Relays — C396 14.6 15.0 14.0 [.57] [.59] [.55] 3.0 [.12] 78.7 [3.10] 45.0 [1.77] Figure 34-97 C396 (6.4 – ...

Page 120

... IEC Contactors & Starters 34-120 XT IEC Power Control Overload Relays — C396 13.8 [.54] 34 Figure 34-99 C396 (22 – 110A) Direct Connect to XT Frame F – G Contactor — Approximate Dimensions in mm [in] 29.9 [1.18] 93.0 [3.66] 49.0 [1.93] Figure 34-100. 110 mm C396 (30 – 150A) + C396CBARXT Direct Connect to XT Frame G Contactor — Approximate Dimensions in mm [in] 73 ...

Page 121

March 2009 Contents Description Page Catalog Number Selection . . . . . . . . . . . . . . . . 34-124 Product Selection . . . . . . . . . . 34-125 Accessories . ...

Page 122

IEC Contactors & Starters 34-122 XT IEC Power Control Manual Motor Protectors Features ■ ON/OFF Rotary Handle with Lockout Provision ■ Visible Trip Indication ■ Class 10 Overload Protection ■ Phase Loss Sensitivity 34 ■ Ambient Temperature Compensation to IEC/EN ...

Page 123

March 2009 CA08102001E IEC Contactors & Starters XT IEC Power Control Manual Motor Protectors For more information visit: www.eaton.com 34-123 Table 34-143. Product Identification No. Description Page Basic Units 1 ...

Page 124

IEC Contactors & Starters 34-124 XT IEC Power Control Manual Motor Protectors 34 XTPB XTPR, XTPM and XTPT B-Frame B-Frame Catalog Number Selection Table 34-144. XT— Catalog Numbering System Designation = IEC Power Control Type PB = Manual Motor Protector ...

Page 125

March 2009 Product Selection Product Selection for Manual Motor Starter Applications When ordering, specify Catalog Numbers according to the following stipulations: Manual Motor Protectors are selected based on the overload current range required for a given motor. This current range ...

Page 126

IEC Contactors & Starters 34-126 XT IEC Power Control Manual Motor Protectors 34 B-Frame D-Frame Table 34-146. XTPR Rotary Manual Motor Protectors with Screw Terminals — Global Ratings and North American Ratings Type 1 and Type 2 Coordination Motor Protective ...

Page 127

March 2009 B-Frame D-Frame Table 34-147. XTPR Manual Self-Protected Motor Starters — North American Ratings, UL 508 Type E Motor Protective Device with Thermal and Magnetic Trip Rated FLA Short Maximum Motor Ratings Uninterrupted Adjustment Circuit Current — Range / ...

Page 128

IEC Contactors & Starters 34-128 XT IEC Power Control Manual Motor Protectors 34 B-Frame Table 34-148. XTPT Transformer Protective Circuit Breakers — Global Ratings Type 1 and Type 2 Coordination For the protection of transformers with a high inrush current. ...

Page 129

... Can be snap-fit to IEC/EN 60715 top-hat rail with 7 height. An appropriate overload relay must be fitted to protect motors against overload. Combinations of the XTPM Manual Motor Protectors and XTCE/XTCR Contactors + XTOB Overload Relays can be found in the Motor Controllers section. When using the XTPM as short-circuit protection for motors with heavy starting duty, the rated operational current I e must be derated during engineering with the following factors: Class ...

Page 130

IEC Contactors & Starters 34-130 XT IEC Power Control Manual Motor Protectors Accessories Auxiliary Contacts Side-Mount Auxiliary Contacts 34 Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT) and can ...

Page 131

March 2009 Side-Mount Trip Indicating Auxiliary Contacts Can be fitted on the right side of manual motor protectors. Can be combined with standard auxiliary contacts. Trip indication: A. General Trip indication (overload) B. Short-circuit trip. Local short-circuit indication by red ...

Page 132

IEC Contactors & Starters 34-132 XT IEC Power Control Manual Motor Protectors Shunt Release Can be used to trip the manual motor protector from a 34 remote location. Can be fitted on the left side of manual motor protectors. Cannot ...

Page 133

... Rotary Handle Mechanisms ship with door interlock disabled. See instruction publication with product for how to enable door interlock. Not for use with XTPAXFAEM20 early-make front mount auxiliary contact. Orders must be placed in multiples of package quantity listed. For use on main switches to IEC/EN 60204. For use on main switches with Emergency-Stop function to IEC/EN 60204. Sealing Facility Table 34-159. Sealing Facility Description Pkg ...

Page 134

IEC Contactors & Starters 34-134 XT IEC Power Control Manual Motor Protectors Three-Phase Commoning Links Frame B 34 For parallel power feed to several manual motor protectors on terminals 1, 3 and 5. Table 34-160. Three-Phase Commoning Links For Use ...

Page 135

March 2009 Shroud for Unused Commoning Link Terminals Table 34-161. Shroud for Unused Terminals of Three-Phase Commoning Links For Use Description with… B-Frame To cover unused terminals XTPR on three-phase common- ing link. Protected against D-Frame direct contact. XTPR Orders ...

Page 136

IEC Contactors & Starters 34-136 XT IEC Power Control Manual Motor Protectors Combination Connection Kits Table 34-164. Combination Connection Kits For Use with… Non-reversing Starters XTPR...B + XTCE...B 34 XTPR...B + XTCE...C XTPR...D + XTCE...D Reversing Starters XTPR...B + XTCE...B01_ ...

Page 137

March 2009 Combination Connection Kits Table 34-164. Combination Connection Kits (Continued) For Use with… Electrical Connection Module XTPR...B + XTCE...C XTPR...D + XTCE...D DIN Rail Adapter Plates XTPAXTPCB XTPAXTPCRB XTPR...B + XTCE...C XTPAXECMC XTPAXECMD XTPR...D + XTCE...C XTPR...D + XTCE...D ...

Page 138

IEC Contactors & Starters 34-138 XT IEC Power Control Manual Motor Protectors Pushbutton MMP Enclosures B-Frame 34 Table 34-165. Insulated Enclosures for Surface Mounting of XTPB Pushbutton Motor-Protective Circuit Breakers — Global Usage Degree of For Use Protection with… IP40 ...

Page 139

... XTPAXENCS65RY as Emergency-Stop switches to IEC/ EN 60204 Cover with aperture dimensioned to XTPAXENCS40 accommodate front of MMP. With black/gray rotary handle XTPAXENCS55B With red/yellow rotary handle for use XTPAXENCS55RY as Emergency-Stop switches to IEC/ EN 60204 For more information visit: www.eaton.com 34-139 Price Approx. Dimensions [in 129 x 90.2 x 115.2 [5 ...

Page 140

... XTPAXENCF55RY use as Emergency-Stop switches to IEC/EN 60204 Description Catalog Number With black/gray rotary handle XTPAXENCSD65B With red/yellow rotary handle for XTPAXENCSD65RY use as Emergency-Stop switches to IEC/EN 60204 For more information visit: www.eaton.com March 2009 Price Approx. Dimensions [in 160 x 100 x 130 [6.30 x 3.94 x 5.12] 160 x 100 x 130 [6 ...

Page 141

March 2009 MMP Enclosure Accessories Table 34-174. XTPR Manual Motor Protector Enclosure Padlock Attachment For Use with… XTPAXENCS65B, XTPAXENCS65RY, XTPAXENCSEM65B, XTPAXENCSEM65RY, XTPAXENCS55B, XTPAXENCS55RY, XTPAXENCSEM55B, XTPAXENCSEM55RY XTPAXENCSD65B, XTPAXENCSD65RY XTPAXENCF55B, XTPAXENCF55RY Orders must be placed in multiples of package quantity listed. Lockable ...

Page 142

IEC Contactors & Starters 34-142 XT IEC Power Control Manual Motor Protectors Technical Data and Specifications Table 34-179. XT Manual Motor Protectors — Technical Data and Specifications Description General Standards 34 Climatic proofing Ambient temperature, °C Storage Open Enclosed Mounting ...

Page 143

March 2009 Table 34-179. XT Manual Motor Protectors — Technical Data and Specifications (Continued) Description Releases Overload release setting range ( Fixed short-circuit release ( Short-circuit release tolerance Phase-failure sensitivity Temperature compensation to IEC/EN ...

Page 144

IEC Contactors & Starters 34-144 XT IEC Power Control Manual Motor Protectors Table 34-181. Undervoltage Release — Technical Data and Specifications Description Cross-sections Solid or flexible conductor with ferrule (mm Solid or stranded (AWG) 34 Main Contacts Rated operational voltage, ...

Page 145

March 2009 Time/Current Curve Characteristics The time/current characteristic, the current limiting charac- 2 teristics and the I t characteristics were determined in accor- dance with DIN VDE 0660 and IEC 60 947. The tripping characteristic of the inverse-time delayed over- ...

Page 146

IEC Contactors & Starters 34-146 XT IEC Power Control Manual Motor Protectors 10 XTPB 8 XTPR Frame XTPM 6 [kA 0.8 0.6 0.4 0.3 0.2 0.1 0.08 0.06 0.04 0.03 0.02 ...

Page 147

March 2009 Manual Motor Protector Short Circuit Ratings Rated uninterrupted current Rated operational current I Rated conditional short circuit current I q — IEC/EN 60947-4-1. Rated ultimate short circuit breaking capacity I cu — IEC/EN 60947-2. Rated ...

Page 148

IEC Contactors & Starters 34-148 XT IEC Power Control Manual Motor Protectors Table 34-185. Ratings for Group Motor Applications — UL 508 / CSA C22.2 No. 14 Catalog Rated FLA Number Uninterrupted Adjustment Current — Range / I u (Amps) ...

Page 149

March 2009 Table 34-186. UL 508 Type E Ratings Manual Motor Line Side FLA Adjustment Range / Overload Protector — Adapter Release — Screw Terminals (Amps) Catalog Catalog Number Number XTPR Frame B + XTPAXLSA XTPRP16BB1 XTPAXLSA 0.1 ...

Page 150

IEC Contactors & Starters 34-150 XT IEC Power Control Manual Motor Protectors Dimensions 93 XTPAXFA _ [3.66 [1.77] 5.5 45 [1.77] [.22] Figure 34-110. Manual Motor Protectors — XTPB (Approximate Dimensions in mm [in]) 130 [5.12] 140 [5.57] ...

Page 151

March 2009 36 [1.42 [.35] [1.02] 68 [2.68] Figure 34-115. Standard Auxiliary Contact — XTPAXSA… (Approximate Dimensions in mm [in]) 36 [1.42 [.35] [1.02] 68 [2.68] Figure 34-116. Trip Indicating Auxiliary Contact — XTPAXSATR… (Approximate Dimensions ...

Page 152

IEC Contactors & Starters 34-152 XT IEC Power Control Manual Motor Protectors 36 [1.42] 205 [8.07] XTPAXCLKA4D 34 36 [1.42] 151 [5.94] XTPAXCLKA3D 36 [1.42] 98 [3.86] XTPAXCLKA2D Figure 34-122. Three-Phase Commoning Link — XTPAXCLKA4D, XTPAXCLKA3D and XTPAXCLKA2D (Approximate Dimensions ...

Page 153

March 2009 158 [6.22] 80 [3.15] 116.5 [4.59] XTPBXENCS40 XTPBXENAS41 XTPBXENCS65 XTPBXENAS65 158 [6.22] 80 [3.15] 116.5 [4.59] 129.5 [5.10] XTPBXENCSLE65 XTPBXENASLE65 XTPBXENCSLO65 XTPBXENASO065 Figure 34-125. Insulated Enclosures for Surface Mounting of XTPB Manual Motor Protectors (Approximate Dimensions in mm ...

Page 154

IEC Contactors & Starters 34-154 XT IEC Power Control Manual Motor Protectors 158 [6.22 [3.15] XTPAXENCS40 30 [1.18] 44 [1.73] 181 160 [7.13] [6.30] 47.5 100 [1.87] [3.94] 104 [4.09] XTPAXENCSH41 XTPAXENAS41 XTPAXENCS41 98 [3.86] 30 [1.18] 44 ...

Page 155

March 2009 129 [5.08] 85 [3.35] 80 [3.15] 96 [3.78] XTPAXENCF40 XTPAXENCF55B XTPAXENCF55RY 58 [2.28] 80 [3.15] 96 [3.78] 124 [4.88] Figure 34-128. Insulated Enclosures for Flush Mounting of XTPR...B Manual Motor Protectors (Approximate Dimensions in mm [in]) CA08102001E IEC ...

Page 156

IEC Contactors & Starters 34-156 XT IEC Power Control Manual Motor Protectors 34 240 [9.45] 160 [6.30] XTPAXENCSD65B XTPAXENCSD65RY 240 [9.45] 160 [6.30] Figure 34-129. Insulated Enclosures for Surface Mounting of XTPR...D Manual Motor Protectors (Approximate Dimensions in mm [in]) ...

Page 157

March 2009 Contents Description Page Standards and Certifications . . . . . . . . . . . . 34-158 Catalog Number Selection . . . . . . . . . . . . . . . . ...

Page 158

IEC Contactors & Starters 34-158 XT IEC Power Control Combination Motor Controllers Standards and Certifications UL 508 Type F Combination Motor Controller ■ IEC Type 2 Approved per IEC 60947-4-1 ■ UL Listed File No. E245398 34 ■ CE Mark ...

Page 159

March 2009 Catalog Number Selection Table 34-188. Combination Motor Controllers — Catalog Numbering System Design = IEC Power Control Type SC = Manual Motor Controller — FVNR SR = Manual Motor Controller — FVR FC = Combination Motor Controller, UL ...

Page 160

IEC Contactors & Starters 34-160 XT IEC Power Control Combination Motor Controllers Product Selection Table 34-189. XTSC and XTSR Manual Motor Controllers (MMC) / Starter Combinations Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor FLA Short- ...

Page 161

March 2009 Table 34-190. XTFC and XTFR Combination Motor Controllers (CMC), UL508 Type F Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor + Required Line Side Adapter FLA Short- Maximum Motor Ratings Adjustment Circuit Maximum Motor ...

Page 162

IEC Contactors & Starters 34-162 XT IEC Power Control Combination Motor Controllers Table 34-191. AC and DC Coil Suffixes Coil Voltage Suffix Code Frame B Contactors 110V 50 Hz, 120V 220V 50 Hz, 240V ...

Page 163

March 2009 Combination Connection Kits Combination Connection Kits include the necessary components to field assemble a Manual Motor Controller with an MMP (XTPR) and Contactor (XTCE). Table 34-193. Combination Connection Kits For Use with… Non-reversing Starters XTPR...B + XTCE...B XTPR...B ...

Page 164

IEC Contactors & Starters 34-164 XT IEC Power Control Combination Motor Controllers Combination Connection Kits Table 34-193. Combination Connection Kits (Continued) For Use with… Electric Contact Module XTPR...B + XTCE...C 34 XTPR...D + XTCE...D DIN Rail Adapter Plates XTPAXTPCB XTPAXTPCRB ...

Page 165

March 2009 Technical Data and Specifications Table 34-194. Manual and Combination Motor Controllers Motor Ratings Assembled Controller FLA Adjustment Range / Overload Release — Non-reversing Reversing I r (Amps) XTSC & XTSR Manual Motor Controllers (MMC) / Starter Combinations XTSC ...

Page 166

IEC Contactors & Starters 34-166 XT IEC Power Control Combination Motor Controllers Table 34-195. XTSC and XTSR Manual Motor Controllers (MMC) / Starter Combinations — Component Bill of Material Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + ...

Page 167

March 2009 Table 34-196. XTFC and XTFR Combination Motor Controllers (CMC), UL508 Type F — Component Bill of Material Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor + Required Line Side Adapter Assembled FLA Adjustment Range ...

Page 168

IEC Contactors & Starters 34-168 XT IEC Power Control Combination Motor Controllers Table 34-197. Manual Motor Controllers Short-Circuit Ratings for UL/CSA Group Installations XTSC & XTSR Manual Motor Controllers (MMC) / Starter Combinations Assembled Controller Non-reversing Reversing 34 XTSC & ...

Page 169

March 2009 Dimensions Figure 34-135. XTSC…BB_ — Approximate Dimensions in mm [in] Figure 34-136. XTSR…BB_ — Approximate Dimensions in mm [in] CA08102001E IEC Contactors & Starters XT IEC Power Control Combination Motor Controllers 32.5 [1.28] To Terminals 178.5 [7.03] 45 ...

Page 170

IEC Contactors & Starters 34-170 XT IEC Power Control Combination Motor Controllers Mounting Holes for M4 Screws or #8 Screws (4 Places) 34 210.8 [8.30] Mounting 9 [.35] Figure 34-137. XTSC…BC_ — Approximate Dimensions in mm [in] Mounting Holes for ...

Page 171

March 2009 Mounting Holes for M5 Screws or #10 Screws (4 Places) 266 [10.47] Mounting 9 [.35] 43.4 [1.71] Mounting Figure 34-139. XTSC…DD_ — Approximate Dimensions in mm [in] Figure 34-140. XTFC…BB_ — Approximate Dimensions in mm [in] CA08102001E IEC ...

Page 172

IEC Contactors & Starters 34-172 XT IEC Power Control Combination Motor Controllers 34 Figure 34-141. XTFR…BB_ — Approximate Dimensions in mm [in] 34 [1.34] Mounting Mounting Holes for M4 Screws or #8 Screws (4 Places) 210.8 [8.30] Mounting 9 [.35] ...

Page 173

March 2009 To Terminals Mounting Holes for M4 Screws or #8 Screws (8 Places) 210.8 [8.30] 9 [.35] 34 [1.34] 45 [1.77] 79 [3.11] 5.3 [.21] Figure 34-143. XTFR…BC_ — Approximate Dimensions in mm [in] Mounting Holes for M5 Screws ...

Page 174

IEC Contactors & Starters 34-174 XT IEC Power Control Contactors and Starters — Enclosed Control 34 ECX Enclosed Control Product Description ® Eaton’s Cutler-Hammer Line includes IEC Contactors, Starters and Combination Motor Controllers (CMCs). Designed to meet Inter- national Standards, ...

Page 175

... Type 4X — Watertight (304-Grade Stainless Steel)/IP66 5 = Type 4X — Watertight (Non-metallic)/IP66 8 = Type 12 — Dust-Tight/IP65 See PG03300001E for Enclosure Type/IP Rating Cross-Reference. Table 34-200. XTOB Overload Relays for Enclosed XT FLA Size B – E Size F – H Size J – L Ratings 7 – 15A 18 – 32A 40 – ...

Page 176

... Cover control for Combination Starters uses 10250T 34 style devices as standard. ■ E22 style cover control options are available (Table 34-203). ■ Selector switches are maintained with lever operators. ■ Pushbuttons are momentary type with extended pushbutton. ■ The kit includes hardware and connecting wires (where possible). ...

Page 177

March 2009 E22 Selector Switch Table 34-203. Type 1, 3R, 4X and 12 E22 Style Combination Starter Cover Control Description Non-reversing No Cover Mounted Pilot Devices START/STOP Pushbuttons (PB) START/STOP PB & Red RUN Light START/STOP PB, Red RUN, & ...

Page 178

IEC Contactors & Starters 34-178 XT IEC Power Control Contactors and Starters — Enclosed Control Product Selection Table 34-204. Class ECX09 — Non-combination Non-reversing Starter Amps Maximum hp Motor 1-Phase 3-Phase Voltage Frame 115 1/4 — 208 ...

Page 179

March 2009 Table 34-204. Class ECX09 — Non-combination Non-reversing Starter (Continued) Amps Maximum hp Coil Voltage @ 60 Hz Motor 1-Phase 3-Phase Voltage Frame J 40 115 3 — 120 208 5 10 208 230 7-1/2 15 240 380 — ...

Page 180

IEC Contactors & Starters 34-180 XT IEC Power Control Contactors and Starters — Enclosed Control Table 34-205. Class ECX10 — Non-combination Reversing Starter Amps Maximum hp Motor 1-Phase 3-Phase Voltage Frame B 7 115 1/4 — 208 3/4 1-1/2 34 ...

Page 181

March 2009 Table 34-205. Class ECX10 — Non-combination Reversing Starter (Continued) Amps Maximum hp Coil Voltage @ 60 Hz Motor 1-Phase 3-Phase Voltage Frame J 40 115 3 — 120 208 5 10 208 230 7-1/2 15 240 380 — ...

Page 182

IEC Contactors & Starters 34-182 XT IEC Power Control Contactors and Starters — Enclosed Control Table 34-206. Class ECX11 — Non-combination Non-reversing Starter with CPT Amps Maximum hp Motor 1-Phase 3-Phase Voltage Frame B 7 115 1/4 — 208 3/4 ...

Page 183

March 2009 Table 34-206. Class ECX11 — Non-combination Non-reversing Starter with CPT (Continued) Amps Maximum hp Coil Voltage @ 60 Hz Motor 1-Phase 3-Phase Voltage Frame J 40 115 3 — 120 208 5 10 208 230 7-1/2 15 240 ...

Page 184

IEC Contactors & Starters 34-184 XT IEC Power Control Contactors and Starters — Enclosed Control Table 34-207. Class ECX19 — Combination Non-reversing Starter — Fusible/Non-fusible Disconnect Amps Maximum hp Motor 1-Phase 3-Phase Voltage Frame B 7 — — — 115 ...

Page 185

March 2009 Table 34-207. Class ECX19 — Combination Non-reversing Starter — Fusible/Non-fusible Disconnect (Continued) Amps Maximum hp Coil Voltage @ 60 Hz Motor 1-Phase 3-Phase Voltage Frame J 40 — — — — 115 3 — 120 208 5 10 ...

Page 186

IEC Contactors & Starters 34-186 XT IEC Power Control Contactors and Starters — Enclosed Control Table 34-208. Class ECX20 — Combination Reversing Starter — Fusible/Non-fusible Disconnect Amps Maximum hp Motor 1-Phase 3-Phase Voltage Frame B 7 — — — 115 ...

Page 187

March 2009 Table 34-208. Class ECX20 — Combination Reversing Starter — Fusible/Non-fusible Disconnect (Continued) Amps Maximum hp Coil Voltage @ 60 Hz Motor 1-Phase 3-Phase Voltage Frame J 40 — — — — 115 3 — 120 208 5 10 ...

Page 188

IEC Contactors & Starters 34-188 XT IEC Power Control Contactors and Starters — Enclosed Control Table 34-209. Class ECX25 — Combination Non-reversing Starter — Circuit Breaker Amps Maximum hp Motor 1-Phase 3-Phase Voltage Frame B 7 115 1/4 — 208 ...

Page 189

March 2009 Table 34-209. Class ECX25 — Combination Non-reversing Starter — Circuit Breaker (Continued) Amps Maximum hp Coil Voltage @ 60 Hz Motor 1-Phase 3-Phase Voltage Frame J 40 115 3 — 120 208 5 10 208 230 7-1/2 15 ...

Page 190

IEC Contactors & Starters 34-190 XT IEC Power Control Contactors and Starters — Enclosed Control Table 34-210. Class ECX26 — Combination Reversing Starter — Circuit Breaker Amps Maximum hp Motor 1-Phase 3-Phase Voltage Frame B 7 115 1/4 — 208 ...

Page 191

March 2009 Table 34-210. Class ECX26 — Combination Reversing Starter — Circuit Breaker (Continued) Amps Maximum hp Coil Voltage @ 60 Hz Motor 1-Phase 3-Phase Voltage Frame J 40 115 3 — 120 208 5 10 208 230 7-1/2 15 ...

Page 192

IEC Contactors & Starters 34-192 XT IEC Power Control Contactors and Starters — Enclosed Control Wiring Diagrams FVNR with Pushbutton Control Stop Start 1 M 2 Reversing ...

Page 193

March 2009 Remote Pilot Devices 2-Wire Control 3/14 1 Not for Use with Auto Reset OL Relays 3-Wire Control Start 3/14 2/13 Stop 1 When More Than One Pushbutton Station is Used, Omit Connector “A” and Connect per Sketch Below ...

Page 194

IEC Contactors & Starters 34-194 XT IEC Power Control Contactors and Starters — Enclosed Control Remote Control Stations SPDT Hold Down Switch Pushbutton For For Rev 5 5 Rev Pushbutton For 3 2 Rev 4 ...

Page 195

March 2009 Dimensions Enclosure Boxes Type 1, 3R Non-combination Starters Table 34-211. Class 09 — FVNR Starters (Non-combination) IEC Size Box (Frame / Amps) Number B – – 25A 1 B – H ...

Page 196

IEC Contactors & Starters 34-196 XT IEC Power Control Contactors and Starters — Enclosed Control Modification Codes Table 34-220. A — Ammeters, Auxiliary Contacts, Accelerating Relays, Autotransformers Modification Catalog Description Number Suffix 34 Ammeter A1 Panel Type Wired to Current ...

Page 197

March 2009 Table 34-222. C — Control Power Transformer, IT. Power Supplies, Control Relays, Cover Control (not elsewhere defined), Current Transformers, Compelling Relay, Control Wiring, Control Circuit Breaker, Separate Control, Customer-Supplied Components, Custom for Advantage, Contactors, Counter, E-Stop Relay, DC/AC ...

Page 198

IEC Contactors & Starters 34-198 XT IEC Power Control Contactors and Starters — Enclosed Control Table 34-224. E — Enclosure Modifications, Elapsed Time Meter, Duplex Outlet, Enclosure for Starter, Enclosure Clear Cover, Enclosure Material Modification Catalog Description Number Suffix Enclosure ...

Page 199

March 2009 Table 34-229. P — Pilot Lights, Pushbuttons, Phase Relays, Potential Transformers, Power Factor Correction Capacitors, Program Timer, Percentage Timer, Photocell (Continued) Modification Catalog Description Number Suffix Pilot Lights P61 Pilot Light — Green STOP (Continued) P62 FORWARD/REVERSE Red ...

Page 200

... IEC Contactors & Starters 34-200 XT IEC Power Control Contactors and Starters — Enclosed Control Table 34-232. S — System Voltage, Selector Switches, Suppressor, Incomplete Sequence Protection, Single-Phase Jumper, Surge Capacitor, Speed Potentiometer Modification Catalog Description Number Suffix System S1 System Voltage Selection for Internal ...

Related keywords