FC4A-J8C1 IDEC, FC4A-J8C1 Datasheet

no-image

FC4A-J8C1

Manufacturer Part Number
FC4A-J8C1
Description
Analog Input Module
Manufacturer
IDEC
Datasheet

Specifications of FC4A-J8C1

No. Of Analog Inputs
8
Supply Voltage
24VDC
External Width
23.25mm
Supply Voltage Max
10V
External Depth
70mm
External Height
90mm
Supply Voltage Min
0V
For Use With
MicroSmart CPU Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
FC9Y-B902
FC4A
SERIES
Analog I/O Module
User’s Manual

Related parts for FC4A-J8C1

FC4A-J8C1 Summary of contents

Page 1

... FC9Y-B902 FC4A Analog I/O Module User’s Manual SERIES ...

Page 2

... Read this user’s manual to make sure of correct operation before starting installation, wiring, operation, maintenance, and inspection of the FC4A series MicroSmart analog I/O modules • All MicroSmart modules are manufactured under IDEC’s rigorous quality control system, but users must add a backup or failsafe provision to the control system using the MicroSmart in applications where heavy damage or personal injury may be caused in case the MicroSmart should fail ...

Page 3

... About This Manual This user’s manual primarily describes entire functions, installation, programming, and troubleshooting procedures of the FC4A series MicroSmart analog I/O modules HAPTER ENERAL NFORMATION General information about the analog I/O modules, applicable CPU module system program version, and WindLDR ver- sion ...

Page 4

... Programming WindLDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Analog I/O Control Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Data Register Allocation Numbers for Analog I/O Modules . . . . . . . . . . . . . . . . . . . 4-8 Analog Input Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 Analog Output Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4- HAPTER ROUBLESHOOTING Troubleshooting Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 I NDEX FC4A M PECIFICATIONS W IRING ONTROL S A I/O M ICRO MART NALOG ODULE U ’ ...

Page 5

... SER Category Type No. FC4A-L03A1 END Refresh Type FC4A-L03AP1 FC4A-J2A1 FC4A-J4CN1 Ladder Refresh Type FC4A-J8C1 FC4A-J8AT1 END Refresh Type FC4A-K1A1 Ladder Refresh Type FC4A-K2C1 Ladder Refresh Type When executing ANST macro In the step after ANST macro (always refreshed whether input to ANST off) Maintains output status when the CPU is stopped ...

Page 6

... NFORMATION Applicable CPU Modules and WindLDR Version END refresh type analog I/O modules as many as listed below can be used with any FC4A and FC5A MicroSmart CPU modules and WindLDR versions. Ladder refresh type analog I/O modules can be used with the FC4A and FC5A MicroSmart CPU module system program versions and WindLDR versions as listed below ...

Page 7

... Power LED (PWR) END refresh type FC4A-L03A1, FC4A-L03AP1, FC4A-J2A1, FC4A-K1A1: Turns on when power is supplied to the analog I/O module. (3) Status LED (STAT) Ladder refresh type FC4A-J4CN1, FC4A-J8C1, FC4A-J8AT1, FC4A-K2C1: Indicates the operating status of the analog I/O module. (4) Terminal No. Indicates terminal numbers. (5) Cable Terminal All analog I/O modules have a removable terminal block ...

Page 8

... MC1.5/11-G-3.81BK (Phoenix Contact) 100 times minimum 50 mA (5V DC (5V DC (24V DC (24V DC (24V DC (24V DC) 85g FC4A-J4CN1 FC4A-J8C1 24V DC 20.4 to 28.8V DC See Analog I/O Module Terminal Arrangement on pages 2-8 to 2-11. MC1.5/10-G-3.81BK (Phoenix Contact) 100 times minimum 50 mA (5V DC (5V DC (24V DC (24V DC (24V DC) ...

Page 9

... Effect of Improper Input Connection Maximum Permanent Allowed Overload (No Damage) Selection of Analog Input Signal Type Calibration or Verification to Maintain Rated Accuracy For Note 1 through Note 4, see page 2-7. FC4A M FC4A-L03A1 / FC4A-J2A1 Voltage Input Current Input 0 to 10V MΩ minimum 10Ω — — ...

Page 10

... Conversion Method Maximum Error at 25°C Cold Junction Input Error Compensation Error Temperature Coefficient Repeatability after Stabilization Time Non-lineality Maximum Error 2-4 FC4A M FC4A-J4CN1 / FC4A-J8C1 Voltage Input Current Input 0 to 10V FC4A-J4CN1: 12Ω 1 MΩ FC4A-J8C1: 100Ω — — ...

Page 11

... Maximum Permanent Allowed Overload (No Damage) Selection of Analog Input Signal Type Calibration or Verification to Maintain Rated Accuracy For Note 1 through Note 4, see page 2-7. FC4A M FC4A-J4CN1 / FC4A-J8C1 Voltage Input Current Input 50000 increments (16 bits) 0.2 mV 0.32 µA Default 50000 Optional: –32768 to 32767 (selectable for each channel) (Note 2) — ...

Page 12

... Crosstalk Isolation Effect of Improper Input Connection Selection of Analog Input Signal Type Calibration or Verification to Maintain Rated Accuracy For Note 1 through Note 4, see page 2-7. 2-6 FC4A M FC4A-J8AT1 NTC –50 to 150°C 100 kΩ maximum 0 maximum 2 ms × channels 10 ms × channels + 1 scan time (Note 1) ...

Page 13

... Rated Accuracy Note 1: Total input system transfer time = Sample repetition time + Internal processing time When using the FC4A-J4CN1, FC4A-J8C1, or FC4A-J8AT1, the total input system transfer time increases in proportion to the number of channels used. Note 2: The data processed in the analog I/O module can be linear-converted to a value between –32768 and 32767. The optional range designation, and analog I/O data minimum and maximum values can be selected using data registers allo- cated to analog I/O modules ...

Page 14

... S ODULE PECIFICATIONS Analog I/O Module Terminal Arrangement and Wiring Diagrams FC4A-L03A1 (Analog I/O Module) — Screw Terminal Type Applicable Terminal Block: • Connect a fuse appropriate for the applied voltage and current draw, at the position shown in the diagram. This is required when equipment containing the MicroSmart is destined for Europe. ...

Page 15

... FC4A-J2A1 (Analog Input Module) — Screw Terminal Type Applicable Terminal Block: FC4A-PMT11P (supplied with the analog input module) • Connect a fuse appropriate for the applied voltage and current draw, at the position shown in the diagram. This is required when equipment containing the MicroSmart is destined for Europe. ...

Page 16

... M S ODULE PECIFICATIONS FC4A-J8C1 (Analog Input Module) — Screw Terminal Type Applicable Terminal Block: • Connect a fuse appropriate for the applied voltage and current draw, at the position shown in the diagram. This is required when equipment containing the MicroSmart is destined for Europe. • Do not connect any wiring to unused terminals. ...

Page 17

... FC4A-K1A1 (Analog Output Module) — Screw Terminal Type Applicable Terminal Block: FC4A-PMT11P (supplied with the analog output module) • Connect a fuse appropriate for the applied voltage and current draw, at the position shown in the diagram. This is required when equipment containing the MicroSmart is destined for Europe. ...

Page 18

... PECIFICATIONS Type of Protection Input Circuits FC4A-L03A1, FC4A-L03AP1, FC4A-J2A1 +V2 +V1 15 MΩ 1 kΩ NC (A) 1 kΩ + (B’) 10Ω 1 kΩ – (B) –V1 FC4A-J8C1 + 100Ω 10 kΩ – Output Circuits FC4A-L03A1, FC4A-L03AP1, FC4A-K1A1 2-12 FC4A M FC4A-J4CN1 CS Input Data + – Input Selection Signal I– ...

Page 19

... Separate the analog I/O lines, particularly resistance thermometer inputs, from motor lines as much as possible to suppress the influence of noises. Separate the analog I/O line from the power line. Analog voltage/current input device Resistance thermometer Analog voltage/current output device FC4A M Fuse 24V DC – – A B’ – ...

Page 20

... M S ODULE PECIFICATIONS Dimensions FC4A-L03A1, FC4A-L03AP1, FC4A-J2A1, FC4A-K1A1, FC4A-K2C1 3.8 FC4A-J4CN1, FC4A-J8C1, FC4A-J8AT1 3.8 2-14 FC4A M 23.5 14.6 *8.5 mm when the clamp is pulled out. 23.5 14.6 *8.5 mm when the clamp is pulled out I ICRO MART NALOG ODULE SER 70.0 70.0 All dimensions in mm. ...

Page 21

... This chapter describes precautions for installing the analog I/O modules in connection with the internal current draw by other expansion modules. For general methods and precautions for installation and wiring of the analog I/O modules, see the FC4A MicroSmart user’s manual (FC9Y-B812). • This equipment is suitable for use in Class I, Division 2, Groups non-hazardous loca- Warning tions only ...

Page 22

... For 2-cable connection UL1015 AWG22 Crimping Tool and Screwdriver Order No. Tool Name Crimping Tool For CPU modules Screwdriver For I/O modules and communication adapter Screw Terminal Tightening Torque 3-2 FC4A M Phoenix Type Order No. AI 1,5 1 0,5 AI-TWIN 2 x 0,75 AI-TWIN 2 x 0,5-8 WH ...

Page 23

... For hardware specifications of analog I/O modules, see page 2-2. System Setup The FC4A and FC5A MicroSmart CPU modules can be used with a maximum of seven expansion I/O modules, which include digital I/O modules and analog I/O modules. Quantity of Applicable Analog I/O Modules ...

Page 24

... Select the slots where analog I/O modules are mounted. All slots are selected to use seven analog I/O modules as default. Click the check box to deselect slots where analog I/O modules are not mounted. When using analog I/O modules on Slots and 7, deselect Slots 2, 4, and 5 as shown below. 4-2 FC4A I ’ ...

Page 25

... Depending on the selected analog I/O module, other parameters available for the selected module are shown. Ladder Refresh Type Configure Parameters dialog box FC4A-J4CN1 FC4A-J8C1 FC4A-J8AT1 FC4A-K2C1 In the Configure Parameters dialog box, parameters in white cells are selectable while gray cells indicate default parame- ters ...

Page 26

... Ladder Refresh Type Configure Parameters dialog box First Data Register No. 6. Enter a filter value (Ladder refresh type analog input modules only). The filter function is available for the FC4A-J4CN1, FC4A-J8C1, and FC4A-J8AT1 only. Filtering ensures smooth input of analog data into the CPU module. Filter Value Without fi ...

Page 27

... When Celsius or Fahrenheit is selected for thermocouple, resistance thermometer, or thermistor signal types on ladder refresh type analog input modules, the scale value can be selected from ×1, ×10, or ×100 depending on the selected signal type. Using this function, the analog input data can be multiplied to ensure precise control. FC4A ...

Page 28

... Repeat the same steps for other slots. 14. When finished, click the OK button to save changes and exit the Set Analog Module Parameters dialog box. 4-6 FC4A M END Refresh Type Data registers are automatically allocated depending on the slot where the analog I/O module is mounted. ...

Page 29

... Analog Input Data Analog Input Operating Status Analog Output Signal Type Analog Output Data Type Analog Output Data Minimum/Maximum Values Analog Output Data Analog Output Operating Status FC4A M Analog Input Module END Refresh Type Ladder Refresh Type FC4A- FC4A- FC4A- L03AP1 J2A1 J4CN1 ...

Page 30

... Analog output data type Analog output data minimum value Analog output data maximum value – Reserved – Note: Data registers allocated to the unused analog I/O module numbers can be used as ordinary data registers. 4-8 FC4A M END Refresh Type Analog I/O Module No D760 ...

Page 31

... Analog I/O Module Quantity of Data Registers for Analog I/O Operation Data register numbers and parameters are shown in the table below. Ladder Refresh Type Analog Input Module Data Register Allocation (FC4A-J4CN1, FC4A-J8C1, and FC4A-J8AT1) Data Register Data Size Number Offset ...

Page 32

... A I/O C NALOG ONTROL Ladder Refresh Type Analog Output Module Data Register Allocation (FC4A-K2C1) Data Register Data Size Number Offset (word) +0 (Low Byte (High Byte +10 1 +11 1 +12 3 4-10 FC4A M Parameter Analog output signal type — Reserved — Analog output data configuration Analog output signal type Analog output data confi ...

Page 33

... X — — X — — X — — X — — X — — X — — X — — — — X — — FC4A- FC4A- FC4A- J4CN1 J8C1 J8AT1 — NTC only X — NTC only — — X FC4A-J8C1 FC4A-J8AT1 0 to 50000 0 to 4000 M ANUAL 4-11 ...

Page 34

... Resistance Resistance (Ω) Analog Input Data 0 to 100000 0 to 10000 ICRO MART NALOG ODULE FC4A-J4CN1 FC4A-J8C1 FC4A-J8AT1 Fahrenheit Temperature (°F) Analog Input Data 32 to 2372 320 to 23720 32 to 2192 320 to 21920 32 to 752 320 to 7520 –148.0 to 932.0 –1480 to 9320 Fahrenheit Temperature (° ...

Page 35

... Filter Value The filter function is available for the ladder input type FC4A-J4CN1, FC4A-J8C1, and FC4A-J8AT1 only. Filtering ensures smooth input of analog data into the CPU module. For the filtering function of analog input signals, see page 4-4. ...

Page 36

... Minimum value over bit 1 Bit 5 to Bit 15 0 Reserved 4-14 FC4A M Analog Input Operating Status (END refresh type) Analog Input Operating Status (Ladder refresh type) Normal operation Initializing, changing configuration, hardware initialization error Parameter configuration normal Parameter configuration error ...

Page 37

... The operating status of each analog output is stored to a data register, such as D773. While the analog output is operating normally, the data register stores 0. The analog output operating status data is updated whether the CPU module is running or stopped. The update occurs at the END processing of every scan or 10 ms, whichever is longer. FC4A M FC4A-L03A1 FC4A-L03AP1 ...

Page 38

... Output data error bit 1 Bit 4 to Bit 15 0 Reserved 4-16 FC4A M Analog Output Operating Status (END refresh type) Analog Output Operating Status (Ladder refresh type) Normal operation Initializing, changing configuration, hardware initialization error Parameter configuration normal Parameter configuration error ...

Page 39

... FC4A-D40S3 Slot No.: Thermistor Operation In this example, the input value from the NTC thermistor is calibrated. When the temperature reaches the preset value, the output is turned off. The thermistor temperature is monitored on an analog meter. FC4A M Analog Input Module Output Module (Thermistor) (Tr. Source) FC4A-J8AT1 ...

Page 40

... NALOG ONTROL Wiring Diagram FC4A-J8AT1 (Analog Input Module) • Thermistor Specifications Type No. NT731ATTD103K38J (KOA) Type RO 10,000Ω T0 298K (25°C) B Parameter FC4A-T08S1 (8-point Transistor Source Output Module) External Device FC4A-K1A1 (Analog Output Module) 4-18 FC4A M Fuse 24V DC – NTC Thermistor B NTC 3,800K Terminal No ...

Page 41

... WindLDR Programming Analog I/O modules are programmed using the ANST macro in WindLDR . Program the ANST macro as shown below. • Analog Input Module FC4A-J8AT1 on Slot 1 DR Allocation Range D630 - D694 I/O Channel Item Filter CH0 Data Type Scale CH1 Data Type CH2 ...

Page 42

... A I/O C NALOG ONTROL • Analog Output Module FC4A-K1A1 on Slot 3 DR Allocation Range D760 - D779 I/O Channel Item Signal Type OUT CH0 Data Type Ladder Diagram As shown in the ladder diagram below, when initialize pulse special internal relay M8120 is used for the ANST macro in parallel with another instruction, load M8120 again for the other instruction ...

Page 43

... Changing Analog Output While CPU is Stopped When using the FC4A-K2C1 analog output module, the analog output value can be changed while the CPU module is stopped. To change the analog output value, store a required output value to the memory addresses allocated to the analog output data. ...

Page 44

... A I/O C NALOG ONTROL 4-22 FC4A I ’ ICRO MART NALOG ODULE SER S M ANUAL ...

Page 45

... After changing settings, was the CPU stopped and restarted? YES Are data registers duplicated? NO Call IDEC for assistance. FC4A M Supply the rated power voltage to the YES analog I/O module. See pages 4-14 and 4-16. YES Make sure of correct parameters. NO Stop and restart the CPU to configure the analog I/O settings ...

Page 46

... Signal Type? NO After changing settings, was the CPU stopped and restarted? YES Are data registers duplicated? NO Call IDEC for assistance. 5-2 FC4A M Does the Status NO DR store status code 4 (external power supply error)? NO Does the Status DR store status code 1 (initializing)? NO ...

Page 47

... M module specifications 2-1 mounting hole layout for direct mounting O operating status 4-3 P parts description 2-1 Phoenix 3-2 PID instruction source operand S4 FC4A M PLC status power supply precautions for programming ANST macro programming WindLDR protection type R resistance S screwdriver specifications analog 4-13 general ...

Page 48

... No. 79, Hsin Tai Wu Road, Sec. 1, Hsi-Chih, Taipei County, Taiwan Tel: +886-2-2698-3929 Fax: +886-2-2698-3931 E-mail: service@tw.idec.com SINGAPORE IDEC IZUMI ASIA PTE. LTD. No. 31, Tannery Lane #05-01 Dragon Land Building, Singapore 347788 Tel: +65-6746-1155 Fax: +65-6844-5995 E-mail: info@sg.idec.com www.idec.com ©2006 IDEC CORPORATION. All Rights Reserved. Manual No. FC9Y-B902-0 01/07 ...